Purpose: The purpose of this study was to systematically review clinical studies on the incidence of abutment screw loosening in single-implant restorations with different implant-abutment connection geometries. Materials and Methods: The literature search was conducted using several electronic databases. Specific terms were used for the database search, which spanned the years 1990 to 2006. The search was augmented by using the option of "related articles" as well as hand searching of references and relevant journals. Relevant studies were selected according to predetermined inclusion and exclusion criteria. Agreement between reviewers was determined by using Cohen's kappa coefficients. Three-year complication-free rates (survival proportions) were calculated with the aid of a survival function, assuming constant failure rates. Summary estimates per group for complication-free rate after 3 years (M-estimator) were calculated using Tukey's biweight estimator. Results: The initial database search yielded 1,526 relevant titles. After the subsequent filtering process, 27 studies were finally selected. Interexaminer agreement ranged from good to perfect. The external-connection group comprised 12 studies following 586 single-implant restorations for a mean follow-up time that ranged from 3 to 5 years. The estimated percent of complication-free single-implant restorations after 3 years was 97.3% (95% Cl: 95.6-98.3). The internal connection group comprised 15 studies following 1,113 single-implant restorations for a mean follow-up time that ranged from 3 to 10 years. The estimated percentage of complication-free single-implant restorations after 3 years was 97.6% (95% Cl: 96.5-98.3). Conclusion: The results show that abutment screw loosening is a rare event in single-implant restorations regardless of the geometry of implant-abutment connection, provided that proper antirotational features and torque are employed.
引用
收藏
页码:681 / 690
页数:10
相关论文
共 50 条
  • [1] Effect of Double Screw on Abutment Screw Loosening in Single-Implant Prostheses
    Shin, Young-Gun
    Kim, So-Yun
    Lee, Ho-Kyu
    Jeong, Chang-Mo
    Lee, So-Hyoun
    Huh, Jung-Bo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (05) : 445 - 447
  • [2] Screw loosening in angulation-correcting single implant restorations: A systematic review of in vitro studies
    Pitman, Jeremy
    Van Craenenbroeck, Maja
    Glibert, Maarten
    Christiaens, Veronique
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (03): : 520 - 527
  • [3] Implant Abutment Screw Loosening: A Review of Effective Factors
    Seddigh, Mohammad Ali
    Mostafavi, Azam Sadat
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (08) : ZE6 - ZE9
  • [4] Mechanism of and factors associated with the loosening of the implant abutment screw: A review
    Huang, Yiqing
    Wang, Jiawei
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (04) : 338 - 345
  • [5] A Current Perspective on Screw-Retained Single-Implant Restorations: A Review of Pertinent Literature
    Priest, George
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2017, 29 (03) : 161 - 171
  • [6] An esthetic solution for single-implant restorations - Type III porcelain veneer bonded to a screw-retained custom abutment: A clinical report
    Magne, Pascal
    Magne, Michel
    Jovanovic, Sascha A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (01): : 2 - 7
  • [7] Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system
    Kitagawa, T
    Tanimoto, Y
    Odaki, M
    Nemoto, K
    Aida, M
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (02) : 457 - 463
  • [8] Study of screw loosening in cementation type implant abutment
    Hwang, BY
    Kim, YS
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1267 - 1267
  • [9] The influence of implant–abutment connection on the screw loosening and microleakage
    Katsuhiro Tsuruta
    Yasunori Ayukawa
    Tatsuya Matsuzaki
    Masafumi Kihara
    Kiyoshi Koyano
    International Journal of Implant Dentistry, 4
  • [10] A study on the abutment screw loosening phenomenon of dental implant
    Kang, YM
    Cho, IH
    JOURNAL OF DENTAL RESEARCH, 1996, 75 (05) : 1261 - 1261