Clinical analysis of speculum-based vaginal packing for high-dose-rate intracavitary tandem and ovoid brachytherapy in cervical cancer

被引:6
|
作者
Sud, Shivani [1 ]
Roth, Toni [2 ]
Jones, Ellen [3 ]
机构
[1] Univ N Carolina, Sch Med, Chapel Hill, NC USA
[2] Brown Univ, Alpert Med Sch, Providence, RI 02912 USA
[3] Univ North Carolina Chapel Hill, Dept Radiat Oncol, Chapel Hill, NC USA
关键词
intracavitary brachytherapy; cervical cancer; rectal dose; bladder dose; speculum; retractor; LATE RECTAL COMPLICATIONS; VOLUME PARAMETERS; SPACER BALLOON; CARCINOMA; REDUCTION; RECOMMENDATIONS; RADIOTHERAPY; RETRACTOR; CISPLATIN; TERMS;
D O I
10.5114/jcb.2018.74316
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Intra-vaginal packing is used to fix the applicator and displace organs at risk (OAR) during high-doserate intracavitary tandem and ovoid brachytherapy (HDR-ICB). We retain the speculum from applicator placement as a dual-function bladder and rectum retractor during treatment. Our objective is to review salient techniques for OAR displacement, share our packing technique, and determine the reduction in dose to OAR and inter-fraction variability of dose to OAR, associated with speculum-based vaginal packing (SBVP) in comparison to conventional gauze packing during HDR-ICB. Material and methods: We reviewed HDR-ICB treatment plans for 45 patients, including 10 who underwent both conventional gauze packing and SBVP. Due to institutional inter-provider practice differences, patients non-selectively received either packing procedure. Packing was performed under conscious sedation, followed by cone beam computed tomography used for dosimetric planning. Maximum absolute and percent-of-prescription dose to the International Commission of Radiation Units bladder and rectal points in addition to D-0.1cc, D-1.0cc, and D-2.0cc volumes of the bladder and rectum were analyzed and compared for each packing method using an independent sample t-test. Results: Of the 179 fractions included, 73% and 27% used SBVP and gauze packing, respectively. For patients prescribed 6 Gy to point A, SBVP was associated with reduced mean D-0.1cc bladder dose, inter-fraction variability in D-0.1cc bladder dose by 9.3% (p = 0.026) and 9.0%, respectively, and statistically equivalent rectal D-0.1cc, D-1.0cc, and D-2.0cc. Patients prescribed 5.5 Gy or 5 Gy to point A after dose optimization, were less likely to benefit from SBVP. In the intra- patient comparison, 80% of patients had reduction in at least one rectum or bladder parameter. Conclusions: In patients with conducive anatomy, SBVP is a cost-efficient packing method that is associated with improved bladder sparing and comparable rectal sparing relative to gauze packing during HDR-ICB without general anesthesia.
引用
收藏
页码:32 / 39
页数:8
相关论文
共 50 条
  • [1] Local vaginal anesthesia during high-dose-rate intracavitary brachytherapy for cervical cancer
    Chen, HC
    Leung, SW
    Wang, CJ
    Sun, LM
    Fang, FM
    Huang, EY
    Wang, SJ
    Yang, CW
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03): : 541 - 544
  • [2] High-dose-rate intracavitary brachytherapy in the management of cervical and vaginal intraepithelial neoplasia
    Ogino, I
    Kitamura, T
    Okajima, H
    Matsubara, S
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (04): : 881 - 887
  • [3] High-dose-rate intracavitary brachytherapy for recurrent cervical cancer in the vaginal stump after hysterectomy
    Kozai, Yuka
    Itoh, Yoshiyuki
    Kawamura, Mariko
    Nakahara, Rie
    Ito, Junji
    Okada, Tohru
    Kikkawa, Fumitaka
    Ikeda, Mitsuru
    Naganawa, Shinji
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2019, 81 (03): : 351 - 358
  • [4] High-Dose-Rate Intracavitary Brachytherapy for Recurrent Cervical Cancer of Vaginal Stump After Hysterectomy
    Soematsu, Y.
    Itoh, Y.
    Nakahara, R.
    Kubota, S.
    Ito, J.
    Kawamura, M.
    Okada, T.
    Naganawa, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E258 - E258
  • [5] The dosimetric impact of vaginal balloon-packing on intracavitary high-dose-rate brachytherapy for gynecological cancer
    Rockey, William M.
    Bhatia, Sudershan K.
    Jacobson, Geraldine M.
    Kim, Yusung
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (01) : 17 - 22
  • [6] Intracavitary hyperthermia and brachytherapy high-dose-rate in vaginal recurrences of uterine cancer
    Parisi, S
    Raguso, A
    Troiano, M
    Corsa, P
    Canistro, A
    Cossa, S
    El Jaouni, M
    TUMORI, 2001, 87 (04) : S130 - S130
  • [7] On the Importance of Inverse Treatment Planning in High-Dose-Rate Brachytherapy with a Tandem-And-Ovoid Applicator for Cervical Cancer
    Gonzalez, Y.
    Shen, C.
    Klages, P.
    Albuquerque, K.
    Jia, X.
    MEDICAL PHYSICS, 2018, 45 (06) : E482 - E483
  • [8] Correlation Between Vaginal Stenosis (VS), Vaginal Packing (VP) Volume, and Vaginal Dose in Cervical Cancer High-Dose-Rate Brachytherapy
    Federico, M.
    Tornero, A.
    Torres Pozas, S.
    Pinar, B.
    Baltar Oramas, D. Rey
    Lara, P.
    Martin Oliva, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : S203 - S204
  • [9] Evaluation of a balloon-based vaginal packing system and patient-controlled analgesia for patients with cervical cancer undergoing high-dose-rate intracavitary brachytherapy
    Xu-Welliver, Meng
    Lin, Lilie L.
    PRACTICAL RADIATION ONCOLOGY, 2013, 3 (04) : 263 - 268
  • [10] Clinical Impact of Escalating Relative High-dose-rate Intracavitary Brachytherapy Dose in Stage IIB Cervical Cancer
    Cho, Oyeon
    Noh, O. Kyu
    Oh, Young-Taek
    Chang, Suk-Joon
    Chun, Mison
    ANTICANCER RESEARCH, 2017, 37 (01) : 327 - 334