摘要
Preprocessing, binning and dataset subsampling are investigated with regard to simultaneous maximisation of the speed, accuracy and robustness of CT-3D rotational angiography (3DRA) registration. Clinical diagnosis and treatment can both take advantage of this integration, because 3DRA allows the shape of vessel structures to be evaluated three-dimensionally with respect to standard 2D projective angiography. The method for optimising preprocessing, binning and subsampling consisted of independent variation of the corresponding parameters to maximise robustness and speed while maintaining subvoxel accuracy; the latter was computed as the sum of the mean squared errors initially present in the registrations with the errors relative to both binning and subsampling. The results suggest the choice of 256 bins, steps between 14 mm (coarse optimisation) and 2.5 mm (fine optimisation) and bone segmentation by threshold, for binning, subsampling and preprocessing, respectively. The application of this parameter set-up to 50 CT-3DRA registrations resulted in a saving, on average, of 40% of the time with respect to the method previously used while registration error was maintained within 2 mm (1.97 mm, 90% confidence interval) and robustness was increased, so that no manual initial realignment was needed in 48 registrations. Validation by the registration of images acquired for a head phantom showed subvoxel residual errors. In conclusion, the proposed procedure can be considered a satisfactory strategy to optimise CT-3DRA registration.
引用
收藏
页码:667 / 671
页数:5
相关论文
共 50 条
  • [1] CT—3D rotational angiography automatic registration: A sensitivity analysis
    J. Stancanello
    C. Cavedon
    P. Francescon
    P. Cerveri
    G. Ferrigno
    F. Causin
    F. Colombo
    Medical and Biological Engineering and Computing, 2005, 43 : 667 - 671
  • [2] Development and validation of a CT-3D rotational anglography registration method for AVM radiosurgery
    Stancanello, J
    Cavedon, C
    Francescon, P
    Cerveri, P
    Ferrigno, G
    Colombo, F
    Perini, S
    MEDICAL PHYSICS, 2004, 31 (06) : 1363 - 1371
  • [3] A robust and automatic CT-3D ultrasound registration method based on segmentation, context, and edge hybrid metric
    He, Baochun
    Zhao, Sheng
    Dai, Yanmei
    Wu, Jiaqi
    Luo, Huoling
    Guo, Jianxi
    Ni, Zhipeng
    Wu, Tianchong
    Kuang, Fangyuan
    Jiang, Huijie
    Zhang, Yanfang
    Jia, Fucang
    MEDICAL PHYSICS, 2023, 50 (10) : 6243 - 6258
  • [4] Automatic registration using implicit shape representations: applications in intraoperative 3D rotational angiography to preoperative CTA registration
    Navneeth Subramanian
    Eric Pichon
    Stephen B. Solomon
    International Journal of Computer Assisted Radiology and Surgery, 2009, 4 : 141 - 146
  • [5] Automatic registration using implicit shape representations: applications in intraoperative 3D rotational angiography to preoperative CTA registration
    Subramanian, Navneeth
    Pichon, Eric
    Solomon, Stephen B.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2009, 4 (02) : 141 - 146
  • [6] 3D CT Angiography for Detection of Intracranial Aneurysms: Comparison with 3D Rotational Angiography
    Li, Qi
    Li, Jialun
    Lv, Fajin
    Xie, Peng
    NEUROLOGY, 2010, 74 (09) : A225 - A225
  • [7] CT-3D angiography of abdominal aortic aneurysms for predicting intraoperative suprarenal aortic cross-clamping
    Neri, E
    Bonanomi, G
    Moretti, M
    Ferrari, M
    Caramella, D
    Bartolozzi, C
    RADIOLOGY, 1999, 213P : 438 - 439
  • [8] CT angiography versus 3D rotational angiography in patients with subarachnoid hemorrhage
    R. S. Bechan
    S. B. van Rooij
    M. E. Sprengers
    J. P. Peluso
    M. Sluzewski
    C. B. Majoie
    W. J. van Rooij
    Neuroradiology, 2015, 57 : 1239 - 1246
  • [9] CT angiography versus 3D rotational angiography in patients with subarachnoid hemorrhage
    Bechan, R. S.
    van Rooij, S. B.
    Sprengers, M. E.
    Peluso, J. P.
    Sluzewski, M.
    Majoie, C. B.
    van Rooij, W. J.
    NEURORADIOLOGY, 2015, 57 (12) : 1239 - 1246
  • [10] An automatic approach for 3D registration of CT scans
    Hu, Yang
    Saber, Eli
    Dianat, Sohail
    Vantaram, Sreenath Rao
    Abhyankar, Vishwas
    IMAGE PROCESSING: ALGORITHMS AND SYSTEMS X AND PARALLEL PROCESSING FOR IMAGING APPLICATIONS II, 2012, 8295