Electrochemical biosensor for sensitively simultaneous determination of dopamine, uric acid, guanine, and adenine based on poly-melamine and nano Ag hybridized film-modified electrode

被引:41
|
作者
Li, Hongying [1 ]
Wang, Xueliang [1 ]
Yu, Zhangyu [1 ]
机构
[1] Heze Univ, Dept Chem & Chem Engn, Heze 274015, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemical biosensor; Simultaneous determination; Poly-melanine; Silver; Hybridized membrane; WALLED CARBON NANOTUBES; GLASSY-CARBON; COMPOSITE FILM; ASCORBIC-ACID; GOLD NANOPARTICLES; VOLTAMMETRIC DETERMINATION; SELECTIVE DETERMINATION; METHYLENE-BLUE; SILVER; NANOCOMPOSITE;
D O I
10.1007/s10008-013-2242-9
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
An electrochemical sensor for simultaneous determination of dopamine (DA), uric acid (UA), guanine (G), and adenine (A) has been constructed by copolymerizing melamine monomer and Ag ions on a glassy carbon electrode (GCE) with cyclic voltammetry. The poly-melamine and nano Ag formed a hybridized film on the surface of the GCE. The morphology of the film was characterized by scanning electron microscope. The electrochemical and electrocatalytic properties of this film were characterized by cyclic voltammetry, linear sweep voltammetry, and square wave voltammetry (SWV). In 0.1 M phosphate buffer solution (pH 4.5), the modified electrode resolved the electrochemical response of DA, UA, G, and A into four well-defined voltammetric oxidation peaks by SWV; the oxidation peak current of DA, UA, G, and A increased 13-, 6-, 7-, and 9-fold, respectively, compared with those at the bare GCE and the SWV peak currents of DA, UA, G, and A with linear concentrations in the ranges of 0.1-50, 0.1-50, 0.1-50, and 0.1-60 mu M, respectively. Based on this, a method for simultaneous determination of these species in mixture was setup. The detection limits were 10 nM for DA, 100 nM for UA, 8 nM for G, and 8 nM for A.
引用
收藏
页码:105 / 113
页数:9
相关论文
共 50 条
  • [1] Electrochemical biosensor for sensitively simultaneous determination of dopamine, uric acid, guanine, and adenine based on poly-melamine and nano Ag hybridized film-modified electrode
    Hongying Li
    Xueliang Wang
    Zhangyu Yu
    Journal of Solid State Electrochemistry, 2014, 18 : 105 - 113
  • [2] Simultaneous electrochemical determination of adenine and guanine using poly 2-naphthol orange film-modified electrode
    Manikandan, Ramalingam
    Deepa, P. N.
    Narayanan, Sangilimuthu Sriman
    IONICS, 2020, 26 (03) : 1475 - 1482
  • [3] Simultaneous Determination of Dopamine, Uric Acid and Guanine at Polyadenine Film Modified Electrode
    Li, Hongying
    Wang, Xueliang
    Wang, Zhaoxia
    ANALYTICAL SCIENCES, 2015, 31 (12) : 1225 - 1231
  • [4] Simultaneous Determination of Dopamine, Uric Acid and Guanine at Polyadenine Film Modified Electrode
    Hongying Li
    Xueliang Wang
    Zhaoxia Wang
    Analytical Sciences, 2015, 31 : 1225 - 1231
  • [5] A highly sensitive method for determination of guanine, adenine and epinephrine using poly-melamine film modified glassy carbon electrode
    Liu, Xiao
    Luo, Liqiang
    Ding, Yaping
    Wu, Qingsheng
    Wei, Youli
    Ye, Daixin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 675 : 47 - 53
  • [6] Poly(glycine)/graphene oxide modified glassy carbon electrode: Preparation, characterization and simultaneous electrochemical determination of dopamine, uric acid, guanine and adenine
    He, Shaoying
    He, Ping
    Zhang, Xingquan
    Zhang, Xiaojuan
    Liu, Kaili
    Jia, Lingpu
    Dong, Faqin
    ANALYTICA CHIMICA ACTA, 2018, 1031 : 75 - 82
  • [7] Selective determination of dopamine and uric acid using electrochemical sensor based on poly(alizarin yellow R) film-modified electrode
    Zhou, Yuanzhen
    Tang, Weimin
    Wang, Jing
    Zhang, Guo
    Chai, Shouning
    Zhang, Liang
    Liu, Ting
    ANALYTICAL METHODS, 2014, 6 (10) : 3474 - 3481
  • [8] Simultaneous Electrochemical Determination of Hypoxanthine and Xanthine by Poly(Threonine) Film-Modified Electrode
    Juban, Kakai Bellaliza B.
    Billones, Junie B.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (02): : 149 - 160
  • [9] Overoxidized polyimidazole/graphene oxide copolymer modified electrode for the simultaneous determination of ascorbic acid, dopamine, uric acid, guanine and adenine
    Liu, Xiaofang
    Zhang, Ling
    Wei, Shaping
    Chen, Shihong
    Ou, Xin
    Lu, Qiyi
    BIOSENSORS & BIOELECTRONICS, 2014, 57 : 232 - 238
  • [10] Simultaneous electrochemical determination of adenine and guanine using poly 2-naphthol orange film–modified electrode
    Ramalingam Manikandan
    P. N. Deepa
    Sangilimuthu Sriman Narayanan
    Ionics, 2020, 26 : 1475 - 1482