On-line near-infrared spectrometer to monitor urea removal in real time during hemodialysis

被引:15
|
作者
Cho, David S. [1 ,2 ]
Olesberg, Jonathon T. [1 ,2 ]
Flanigan, Michael J. [3 ]
Arnold, Mark A. [1 ,2 ]
机构
[1] Univ Iowa, Dept Chem, Iowa City, IA 52242 USA
[2] Univ Iowa, Optic Sci & Technol Ctr, Iowa City, IA 52242 USA
[3] Univ Iowa, Caver Coll Med, Dept Internal Med, Iowa City, IA 52242 USA
关键词
near-infrared spectroscopy; NIR spectroscopy; urea monitoring; hemodialysis;
D O I
10.1366/000370208785284411
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The ex vivo removal of urea during hemodialysis treatments is monitored in real time with a noninvasive near-infrared spectrometer. The spectrometer uses a temperature-controlled acousto optical tunable filter (AOFT) in conjunction with a thermoelectrically cooled extended wavelength InGaAs detector to provide spectra with a 20 cm(-1) resolution over the combination region (4000-5000 cm(-1)) of the near-infrared spectrum. Spectra are signal averaged over 15 seconds to provide root mean square noise levels of 24 micro-absorbance units for 100% lines generated over the 4600-4500 cm(-1) spectral range. Combination spectra of the spent dialysate stream are collected in real-time as a portion of this stream passes through a sample holder constructed from a 1.1 mm inner diameter tube of Teflon. Real-time spectra are collected during 17 individual dialysis sessions over a period of 10 days. Reference samples were extracted periodically during each session to generate 87 unique samples with corresponding reference concentrations for urea, glucose, lactate, and creatinine. A series of calibration models are generated for urea by using the partial least squares (PLS) algorithm and each model is optimized in terms of number of factors and spectral range. The best calibration model gives a standard error of prediction (SEP) of 0.30 mM based on a random splitting of spectra generated from all 87 reference samples collected across the 17 dialysis sessions. PLS models were also developed by using spectra collected in early sessions to predict urea concentrations from spectra collected in subsequent sessions. SEP values for these prospective models range from 0.37 mM to 0.52 mM. Although higher than when spectra are pooled from all 17 sessions, these prospective SEP values are acceptable for monitoring the hemodialysis process. Selectivity for urea is demonstrated and the selectivity properties of the PLS calibration models are characterized with a pure component selectivity analysis.
引用
收藏
页码:866 / 872
页数:7
相关论文
共 50 条
  • [1] Near-infrared spectroscopy as a real-time monitor
    Widman, Ronald A.
    SURGICAL NEUROLOGY, 2007, 68 (03): : 296 - 296
  • [2] A rugged near-infrared spectrometer for the real-time measurement of grains during harvest
    von Rosenberg, CW
    Abbate, A
    Drake, J
    Mayes, DM
    SPECTROSCOPY, 2000, 15 (06) : 34 - 38
  • [3] Handheld near-infrared spectrometer allows on-line prediction of beef quality traits
    Goi, Arianna
    Hocquette, Jean-Francois
    Pellattiero, Erika
    De Marchi, Massimo
    MEAT SCIENCE, 2022, 184
  • [4] Handheld near-infrared spectrometer for on-line monitoring of biodiesel production in a continuous process
    Sales, Rafaella
    da Silva, Neirivaldo C.
    da Silva, Josivan P.
    Franca, Higor H.
    Pimentel, Maria Fernanda
    Stragevitch, Luiz
    FUEL, 2019, 254
  • [5] Handheld near-infrared spectrometer allows on-line prediction of beef quality traits
    Goi, Arianna
    Hocquette, Jean-François
    Pellattiero, Erika
    De Marchi, Massimo
    Meat Science, 2022, 184
  • [6] Near-infrared spectroscopy for measuring urea in hemodialysis fluids
    Eddy, CV
    Arnold, MA
    CLINICAL CHEMISTRY, 2001, 47 (07) : 1279 - 1286
  • [7] Noninvasive urea monitoring during hemodialysis by transcutaneous near-infrared spectroscopy.
    Rohrscheib, M
    Zager, P
    Robinson, R
    Rowe, R
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 : 414A - 414A
  • [8] Investigation on spectral standardization among multi-channel of an on-line near-infrared spectrometer
    Sun, Xiting
    Zhang, Peng
    Shen, Ziwei
    Yuan, Hongfu
    Song, Chunfeng
    Han, Xiaolin
    Xiu, Yuan
    Lv, Zhi
    Hu, Aiqin
    VIBRATIONAL SPECTROSCOPY, 2021, 113
  • [9] Near-infrared spectroscopic measurement of urea in dialysate samples collected during hemodialysis treatments
    Eddy, CV
    Flanigan, M
    Arnold, MA
    APPLIED SPECTROSCOPY, 2003, 57 (10) : 1230 - 1235
  • [10] Analytical Method Quality by Design for an On-Line Near-Infrared Method to Monitor Blend Potency and Uniformity
    Corredor, Claudia C.
    Lozano, Ruben
    Bu, Xin
    McCann, Ryan
    Dougherty, Jeffrey
    Stevens, Tim
    Both, Douglas
    Shah, Pankaj
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2015, 10 (01) : 47 - 55