Comparison of thermal neutron detection efficiency of 6Li scintillation glass and 3He gas proportional tube

被引:5
|
作者
Xu Ming [1 ,2 ]
Tang Zhi-Cheng [1 ]
Chen Guo-Ming [1 ]
Tao Jun-Quan [1 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
thermal neutron; detection efficiency; Li-6 incorporated scintillation glass; He-3 gas proportional tube; flash ADC; GEANT4;
D O I
10.1088/1674-1137/37/10/106001
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
We report on a comparison study of the He-3 gas proportional tube and the Li-6 incorporated scintillation glasses on thermal neutron detection efficiency. Both He-3 and Li-6 are used commonly for thermal neutron detection because of their high neutron capture absorption coefficient. By using a neutron source Cf-252 and a paraffin moderator in an alignment system, we can get a small beam of thermal neutrons. A flash ADC is used to measure the thermal neutron spectrum of each detector, and the detected number of events is determined from the spectrum, then we can calculate the detection efficiency of different detectors. Meanwhile, the experiment has been modeled with GEANT4 to validate the results against the Monte Carlo simulation.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Comparison of thermal neutron detection ef f iciency of 6Li scintillation glass and 3He gas proportional tube
    徐明
    唐志成
    陈国明
    陶军全
    Chinese Physics C, 2013, 37 (10) : 35 - 40
  • [2] Comparison of thermal neutron detection ef f iciency of 6Li scintillation glass and 3He gas proportional tube
    徐明
    唐志成
    陈国明
    陶军全
    Chinese Physics C, 2013, (10) : 35 - 40
  • [3] 9BE(3HE,6LI)6LI REACTION
    TAYLOR, MC
    PHILLIPS, GC
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (04): : 566 - &
  • [4] 3He proportional counter development for thermal neutron detection
    Fares, Mohamed
    Messai, Adnane
    Begaa, Samir
    Salem, Maameri
    Negara, Kassida
    Debili, Mohamed Yacine
    Messaoudi, Mohammed
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2021, 5 (02) : 264 - 272
  • [5] 3He proportional counter development for thermal neutron detection
    Mohamed Fares
    Adnane Messai
    Samir Begaa
    Maameri Salem
    Kassida Negara
    Mohamed Yacine Debili
    Mohammed Messaoudi
    Radiation Detection Technology and Methods, 2021, 5 : 264 - 272
  • [6] STUDY OF REACTION 6LI(3HE,P) AND 6LI(3HE,PALPHAALPHA) BELOW 2 MEV
    VIGNON, B
    LIGEON, E
    LONGEQUEUE, JP
    JOURNAL DE PHYSIQUE, 1969, 30 (11-1): : 913 - +
  • [7] A STUDY OF REACTION 9BE(3HE 6LI)6LI
    TAYLOR, MC
    PHILLIPS, GC
    NUCLEAR PHYSICS A, 1969, A126 (03) : 615 - &
  • [8] Comparison of neutron scintillation detectors with a 3He proportional counter for the spallation neutron source (SNS)
    Engels, R
    Kemmerling, G
    Rongen, H
    Schelten, J
    Cooper, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 923 - 925
  • [9] Comparison of neutron scintillation detectors with a 3He proportional counter for the Spallation Neutron Source, SNS
    Engels, R
    Kemmerling, G
    Rongen, H
    Schelten, J
    Cooper, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 338 - 340
  • [10] Position-dependent neutron detection efficiency loss in 3He gas proportional counters
    Peplowski, Patrick N.
    Yokley, Zachary W.
    Liebel, Madison
    Cheng, Shuo
    Elphic, Richard C.
    Hoogerheide, Shannon F.
    Lawrence, David J.
    Nico, Jeffrey S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 982