Low-temperature solution processing of palladium/palladium oxide films and their pH sensing performance

被引:24
|
作者
Qin, Yiheng [1 ,2 ]
Alam, Arif U. [1 ]
Pan, Si [3 ]
Howlader, Matiar M. R. [1 ]
Ghosh, Raja [3 ]
Selvaganapathy, P. Ravi [4 ]
Wu, Yiliang [2 ]
Deen, M. Jamal [1 ]
机构
[1] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON L8S 4K1, Canada
[2] Xerox Res Ctr Canada Ltd, Adv Mat Lab, Mississauga, ON L5K 2L1, Canada
[3] McMaster Univ, Dept Chem Engn, Hamilton, ON L8S 4L7, Canada
[4] McMaster Univ, Dept Mech Engn, Hamilton, ON L8S 4L7, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
PH sensor; Potentiometric sensing; Palladium oxide; Solution processing; Low-temperature; PALLADIUM ELECTRODE; IRIDIUM; FABRICATION; STABILITY; RUTHENIUM; SENSORS;
D O I
10.1016/j.talanta.2015.08.062
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly sensitive, easy-to-fabricate, and low-cost pH sensors with small dimensions are required to monitor human bodily fluids, drinking water quality and chemical/biological processes. In this study, a low-temperature, solution-based process is developed to prepare palladium/palladium oxide (Pd/PdO) thin films for pH sensing. A precursor solution for Pd is spin coated onto pre-cleaned glass substrates and annealed at low temperature to generate Pd and PdO. The percentages of PdO at the surface and in the bulk of the electrodes are correlated to their sensing performance, which was studied by using the X-ray photoelectron spectroscope. Large amounts of PdO introduced by prolonged annealing improve the electrode's sensitivity and long-term stability. Atomic force microscopy study showed that the low-temperature annealing results in a smooth electrode surface, which contributes to a fast response. Nanovoids at the electrode surfaces were observed by scanning electron microscope, indicating a reason for the long-term degradation of the pH sensitivity. Using the optimized annealing parameters of 200 degrees C for 48 h, a linear pH response with sensitivity of 64.71 +/- 0.56 mV/pH is obtained for pH between 2 and 12. These electrodes show a response time shorter than 18 s, hysteresis less than 8 mV and stability over 60 days. High reproducibility in the sensing performance is achieved. This low-temperature solution-processed sensing electrode shows the potential for the development of pH sensing systems on flexible substrates over a large area at low cost without using vacuum equipment. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:517 / 524
页数:8
相关论文
共 50 条
  • [1] Low-temperature co oxidation on iron oxide supported palladium
    Pavlova, SN
    Savchenko, VI
    Sadykov, VA
    Zaikovskii, VI
    Kalinkin, AV
    REACTION KINETICS AND CATALYSIS LETTERS, 1996, 59 (01): : 103 - 110
  • [2] Photochemistry in the Low-Temperature Processing of Metal Oxide Thin Films by Solution Methods
    Bretos, Inigo
    Jimenez, Ricardo
    Ricote, Jesus
    Calzada, M. Lourdes
    CHEMISTRY-A EUROPEAN JOURNAL, 2020, 26 (42) : 9277 - 9291
  • [3] CHLORINATED PALLADIUM-ALUMINUM-OXIDE CATALYSTS ON LOW-TEMPERATURE ISOMERIZATION
    GIANNETT.JP
    SEBULSKY, RT
    ERDOL UND KOHLE ERDGAS PETROCHEMIE VEREINIGT MIT BRENNSTOFF-CHEMIE, 1970, 23 (01): : 47 - &
  • [4] Low-temperature solution processing of stibnite thin films
    McCarthy, Carrie
    Brutchey, Richard
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [5] AN EXAMINATION OF THE PALLADIUM PALLADIUM OXIDE SYSTEM AND ITS UTILITY FOR PH-SENSING ELECTRODES
    KINOSHITA, E
    INGMAN, F
    EDWALL, G
    GLAB, S
    ELECTROCHIMICA ACTA, 1986, 31 (01) : 29 - 38
  • [6] PALLADIUM-PALLADIUM OXIDE PH ELECTRODES
    GRUBB, WT
    KING, LH
    ANALYTICAL CHEMISTRY, 1980, 52 (02) : 270 - 273
  • [7] PALLADIUM - PALLADIUM OXIDE MINIATURE PH ELECTRODE
    LIU, CC
    BOCCHICCHIO, BC
    OVERMYER, PA
    NEUMAN, MR
    SCIENCE, 1980, 207 (4427) : 188 - 189
  • [8] TETRACARBONYLS OF PALLADIUM AND PLATINUM IN LOW-TEMPERATURE MATRICES
    HUBER, H
    MOSKOVIT.M
    KUNDIG, P
    OZIN, GA
    NATURE-PHYSICAL SCIENCE, 1972, 235 (57): : 98 - &
  • [9] Nanostructuring of Palladium with Low-Temperature Helium Plasma
    Fiflis, P.
    Christenson, M. P.
    Connolly, N.
    Ruzic, D. N.
    NANOMATERIALS, 2015, 5 (04) : 2007 - 2018
  • [10] Gas sensing behavior of palladium oxide for carbon monoxide at low working temperature
    Zheng, Yangong
    Qiao, Qiao
    Wang, Jing
    Li, Xiaogan
    Jian, Jiawen
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 212 : 256 - 263