Long-term results with a new introducer method with gastropexy for percutaneous endoscopic gastrostomy

被引:47
|
作者
Dormann, Arno J. [1 ]
Wejda, Bernd
Kahl, Stefan
Huchzermeyer, Hans
Ebert, Matthias P.
Malfertheiner, Peter
机构
[1] Krankenhaus Holweide, Kliniken Stadt Koln, D-51058 Cologne, Germany
[2] Otto Von Guericke Univ, Dept Gastroenterol Hepatol & Infect Dis, Magdeburg, Germany
[3] Minden Hosp, Dept Internal Med, Minden, Germany
[4] Tech Univ Munich, Klinikum Rechts Isar, Dept Med 2, D-8000 Munich, Germany
来源
AMERICAN JOURNAL OF GASTROENTEROLOGY | 2006年 / 101卷 / 06期
关键词
D O I
10.1111/j.1572-0241.2006.00541.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVE: Percutaneous endoscopic gastrostomy (PEG) using the pull-technique is the standard method for enteral feeding in patients with swallowing disorders. A different introducer technique with endoscopically controlled gastropexy is available avoiding oropharyngeal passage with the internal bumper. The aim of the study was to assess long-term safety of this technique. MATERIAL AND METHODS: Between January 1999 and November 2001, 684 patients received a PEG in our prospective cohort trial. In 92.5% of cases a PEG was applied using the pull-through technique. In 6.7% of the patients (40 males, 6 females, mean age 60.6 yr) primary PEG application using the pull-through technique was not possible and an endoscopical controlled introducer PEG (Cliny PEG 13 CH (= 13 F), AP Nenno, Germany) with two gastropexies was placed. Data collection criteria included application success, infectious complications (within 180 days), other complications (within 180 days), and mortality (within 180 days). Procedure, catheter change, and follow-up were standardized. RESULTS: PEG placement was successful in all patients. During initial follow-up we saw a low rate of minor problems. In one case a peristomal peritonitis was seen due to detachment of two gastropexy sutures. During long-term follow-up only one local infection requiring antibiotic treatment occurred on day 14. We observed no treatment related mortality. In most of the patients the primary catheter was changed into a secondary system as scheduled. The average observation period was 131.8 days (range: 15-180 days). CONCLUSION: The Cliny PEG 13 CH can be placed safely in an endoscopically controlled introducer procedure with dual gastropexy. Long-term follow-up of the patients revealed only minor complications. Primary indication is given in patients in whom PEG placement using the pull-through technique is not possible.
引用
收藏
页码:1229 / 1234
页数:6
相关论文
共 50 条
  • [1] Prospective multicenter long term follow up results of new introducer percutaneous endoscopic gastrostomy method with gastropexy in 89 patients
    Shastri, Yogesh
    Tessmer, Angelika
    Hoepffner, Nicolas
    Stein, JueRgen
    GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB260 - AB260
  • [2] First experience with a new introducer method for percutaneous endoscopic gastrostomy (PEG) using a gastropexy suture
    Huchzermeyer, H
    GASTROINTESTINAL ENDOSCOPY, 2001, 53 (05) : AB208 - AB208
  • [3] Modified percutaneous endoscopic gastrostomy (PEG) with gastropexy - early experience with a new introducer technique
    Dormann, AJ
    Glosemeyer, R
    Leistner, U
    Deppe, H
    Roggel, R
    Wigginghaus, B
    Huchzermeyer, H
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2000, 38 (12): : 933 - 938
  • [4] A new device for the introducer percutaneous endoscopic gastrostomy technique
    Giordano-Nappi, Jose H.
    Ishioka, Shinichi
    Maluf-Filho, Fauze
    Hondo, Fabio Y.
    Matuguma, Sergio E.
    Cecconello, Ivan
    Sakai, Paulo
    GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB260 - AB261
  • [5] GASTROPEXY IN COMBINATION WITH PERCUTANEOUS ENDOSCOPIC GASTROSTOMY
    VANDERWERKEN, C
    VANVROONHOVEN, TJMV
    JUTTMANN, JR
    STUIFBERGEN, WNHM
    CHIRURG, 1987, 58 (02): : 118 - 119
  • [6] Long-Term Results of Percutaneous Radiologic Gastrostomy and Gastrojejunostomy in Children With Emphasis on Technique: Single or Double Gastropexy?
    Akinci, Devrim
    Ciftci, Turkmen T.
    Kaya, Diana
    Ozmen, Mustafa N.
    Akhan, Okan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1231 - 1237
  • [7] A new device for the introducer technique for percutaneous endoscopic gastrostomy placement
    Giordano-Nappi, J. H.
    Ishioka, S.
    Maluf-Filho, F.
    Hondo, F. Y.
    Matuguma, S. E.
    Sakai, P.
    ENDOSCOPY, 2007, 39 : E274 - E275
  • [8] New Introducer Method for Percutaneous Gastrostomy in a Porcine Model
    Fang, John
    Maxwell, Christopher
    Carlisle, James
    Glasgow, Robert
    Hilden, Kristen
    Ollerenshaw, Jeremy
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2009, 104 : S50 - S51
  • [9] PERCUTANEOUS ENDOSCOPIC GASTROSTOMY BY THE PULL AND INTRODUCER METHODS
    DEITEL, M
    BENDAGO, M
    SPRATT, EH
    BURUL, CJ
    TO, TB
    CANADIAN JOURNAL OF SURGERY, 1988, 31 (02) : 102 - 104
  • [10] Care and long-term maintenance of percutaneous endoscopic gastrostomy tubes
    McClave, Stephen A.
    Neff, Rita L.
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2006, 30 (01) : S27 - S38