Stroke Damage Detection Using Classification Trees on Electrical Bioimpedance Cerebral Spectroscopy Measurements

被引:15
|
作者
Atefi, Seyed Reza [1 ]
Seoane, Fernando [1 ,2 ]
Thorlin, Thorleif [3 ]
Lindecrantz, Kaj [1 ,2 ,4 ]
机构
[1] Royal Inst Technol, Sch Technol & Hlth, SE-14152 Huddinge, Sweden
[2] Univ Boras, Sch Engn, SE-50190 Boras, Sweden
[3] Univ Gothenburg, Inst Neurosci & Physiol, Sahlgrenska Acad, SE-40530 Gothenburg, Sweden
[4] Karolinska Inst, Dept Clin Sci Intervent & Technol, SE-14157 Stockholm, Sweden
关键词
stroke; electrical bioimpedance spectroscopy; classification tree; cole parameters; IMPEDANCE MEASUREMENT; DIELECTRIC-PROPERTIES; SPREADING DEPRESSION; BIOLOGICAL TISSUES; ANESTHETIZED RAT; SCALP ELECTRODES; HEART-DISEASE; HUMAN-BRAIN; ISCHEMIA; TIME;
D O I
10.3390/s130810074
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
After cancer and cardio-vascular disease, stroke is the third greatest cause of death worldwide. Given the limitations of the current imaging technologies used for stroke diagnosis, the need for portable non-invasive and less expensive diagnostic tools is crucial. Previous studies have suggested that electrical bioimpedance (EBI) measurements from the head might contain useful clinical information related to changes produced in the cerebral tissue after the onset of stroke. In this study, we recorded 720 EBI Spectroscopy (EBIS) measurements from two different head regions of 18 hemispheres of nine subjects. Three of these subjects had suffered a unilateral haemorrhagic stroke. A number of features based on structural and intrinsic frequency-dependent properties of the cerebral tissue were extracted. These features were then fed into a classification tree. The results show that a full classification of damaged and undamaged cerebral tissue was achieved after three hierarchical classification steps. Lastly, the performance of the classification tree was assessed using Leave-One-Out Cross Validation (LOO-CV). Despite the fact that the results of this study are limited to a small database, and the observations obtained must be verified further with a larger cohort of patients, these findings confirm that EBI measurements contain useful information for assessing on the health of brain tissue after stroke and supports the hypothesis that classification features based on Cole parameters, spectral information and the geometry of EBIS measurements are useful to differentiate between healthy and stroke damaged brain tissue.
引用
收藏
页码:10074 / 10086
页数:13
相关论文
共 50 条
  • [1] Electrical Bioimpedance Cerebral Monitoring. Preliminary Results from Measurements on Stroke Patients
    Atefi, S. R.
    Seoane, F.
    Lindecrantz, K.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 126 - 129
  • [2] Detection and differentiation of bacteria by electrical bioimpedance spectroscopy
    Gnaim, Rima
    Golberg, Alexander
    Sheviryov, Julia
    Rubinsky, Boris
    Gonzalez, Cesar A.
    BIOTECHNIQUES, 2020, 69 (01) : 27 - +
  • [3] Detection and Classification of Measurement Errors in Bioimpedance Spectroscopy
    Ayllnon, David
    Gil-Pita, Roberto
    Seoane, Fernando
    PLOS ONE, 2016, 11 (06):
  • [4] Adaptive Frequency Distribution for Electrical Bioimpedance Spectroscopy Measurements
    Seoane, F.
    Ferreira, J.
    Buendia, R.
    Lindecrantz, K.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 562 - 565
  • [5] STROKE VOLUME MEASUREMENTS BY ELECTRICAL BIOIMPEDANCE AND ECHOCARDIOGRAPHY IN HEALTHY-VOLUNTEERS
    HUANG, KC
    STODDARD, M
    TSUEDA, K
    HEINE, MF
    THOMAS, MH
    WHITE, M
    WIEMAN, TJ
    CRITICAL CARE MEDICINE, 1990, 18 (11) : 1274 - 1278
  • [6] Automated criterion-based analysis for Cole parameters assessment from cerebral neonatal electrical bioimpedance spectroscopy measurements
    Seoane, F.
    Ward, L. C.
    Lindecrantz, Kaj
    Lingwood, B. E.
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (08) : 1363 - 1377
  • [7] Detection and localization of internal haemorrhaging using electrical bioimpedance
    Morse, J.
    Fenech, M.
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [8] A comparative study of PCA, SIMCA and Cole model for classification of bioimpedance spectroscopy measurements
    Nejadgholi, Isar
    Bolic, Miodrag
    COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 63 : 42 - 51
  • [9] Cole Equation and Parameter Estimation from Electrical Bioimpedance Spectroscopy Measurements - A Comparative Study
    Ayllon, David
    Seoane, Fernando
    Gil-Pita, Roberto
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3779 - 3782
  • [10] Damage sensing and fracture detection of CNT paste using electrical resistance measurements
    Kwon, Dong-Jun
    Wang, Zuo-Jia
    Choi, Jin-Yeong
    Shin, Pyeong-Su
    DeVries, K. Lawrence
    Park, Joung-Man
    COMPOSITES PART B-ENGINEERING, 2016, 90 : 386 - 391