Local effect of titanium implant corrosion: an experimental study in rats

被引:54
|
作者
Olmedo, D. G. [1 ]
Duffo, G. [2 ]
Cabrini, R. L. [1 ,3 ]
Guglielmotti, M. B. [1 ]
机构
[1] Univ Buenos Aires, Sch Dent, Dept Oral Pathol, Natl Res Council CONICET, Buenos Aires, DF, Argentina
[2] Natl Res Council CONICET, Natl Atom Energy Commiss, Dept Mat, RA-1650 Buenos Aires, DF, Argentina
[3] Natl Atom Energy Commiss, Dept Radiobiol, Buenos Aires, DF, Argentina
关键词
titanium corrosion; metal ion release; pitting; macrophage; oral surgery; osteolysis;
D O I
10.1016/j.ijom.2008.05.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate histologically the biological effect of pitting corrosion and to contribute clinically relevant data on the permanence of titanium metal structures used in osteosynthesis in the body. Commercially pure titanium laminar implants (control) and commercially pure titanium laminar implants with pitting corrosion (experimental) were implanted in the tibiae of rats. At 14 days post-implantation the animals were killed. The tibiae were resected, fixed, radiographed and processed for embedding in methyl methacrylate. Percentage of bone-implant contact and peri-implant bone Volume were evaluated. The histological study of the titanium implants Submitted to pitting corrosion showed scarce bone-implant contact, it was only present in the areas with no pitting and/or surface alterations. There was a statistically significant lower percentage of bone-implant contact in the experimental group (6% +/- 4) than in the control group (26% +/- 6) (P < 0.001). Products of corrosion in the peri-implant bed, especially around the blood vessels and areas of bone marrow in the metal-tissue interface, were observed. The microchemical analysis Of Corrosion products revealed the presence of titanium. The adverse local effects caused by pitting corrosion Suggest that titanium plates and grids should be used with caution as permanent fixation structures.
引用
收藏
页码:1032 / 1038
页数:7
相关论文
共 50 条
  • [1] Titanium Implant Corrosion Local Effect on Bone
    Schliephake, H.
    MKG-CHIRURG, 2009, 2 (03): : 218 - 219
  • [2] Development of a Novel Nanotextured Titanium Implant. An Experimental Study in Rats
    Pelegrine, Andre Antonio
    Moy, Peter Karyen
    Moshaverinia, Alireza
    do Amaral Escada, Ana Lucia
    Calvo-Guirado, Jose Luis
    Rosifini Alves Claro, Ana Paula
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (07):
  • [3] Effect of insertion torque on titanium implant osseointegration: an animal experimental study
    Duyck, Joke
    Roesems, Rutger
    Cardoso, Marcio V.
    Ogawa, Toru
    Camargos, Germana De Villa
    Vandamme, Katleen
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (02) : 191 - 196
  • [4] STUDY OF CORROSION BETWEEN A TITANIUM IMPLANT AND DENTAL ALLOYS
    RECLARU, L
    MEYER, JM
    JOURNAL OF DENTISTRY, 1994, 22 (03) : 159 - 168
  • [5] Effect of Diabetes Mellitus on Implant Osseointegration of Titanium Screws: An Animal Experimental Study
    Xiao, Lei
    Zhou, Yi-juan
    Jiang, Ya-bin
    Tam, Man Seng
    Cheang, Lek Hang
    Wang, Hua-jun
    Zha, Zhen-gang
    Zheng, Xiao-fei
    ORTHOPAEDIC SURGERY, 2022, 14 (06) : 1217 - 1228
  • [6] Effect of lycopene on titanium implant osseointegration in ovariectomized rats
    Li, Xiaojie
    Xue, Wenli
    Cao, Yong
    Long, Yanming
    Xie, Mengsheng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [7] Effect of lycopene on titanium implant osseointegration in ovariectomized rats
    Xiaojie Li
    Wenli Xue
    Yong Cao
    Yanming Long
    Mengsheng Xie
    Journal of Orthopaedic Surgery and Research, 13
  • [8] The effect of oxytocin on osseointegration of titanium implant in ovariectomized rats
    Wang, Maiquan
    Lan, Lingli
    Li, Ting
    Li, Jiqing
    Li, Yunfeng
    CONNECTIVE TISSUE RESEARCH, 2016, 57 (03) : 220 - 225
  • [9] Experimental study on the biocompatibility of keratoprosthesis with improved titanium implant
    Li, Li
    Jiang, Hua
    Wang, Li-Qiang
    Huang, Yi-Fei
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (11) : 1741 - 1745
  • [10] Experimental study on the biocompatibility of keratoprosthesis with improved titanium implant
    Li Li
    Hua Jiang
    Li-Qiang Wang
    Yi-Fei Huang
    International Journal of Ophthalmology, 2018, 11 (11) : 1741 - 1745