NGAL Correlates with Femoral and Carotid Plaque Volume Assessed by Sonographic 3D Plaque Volumetry

被引:6
|
作者
Schreinlechner, Michael [1 ]
Noflatscher, Maria [1 ]
Lener, Daniela [1 ]
Bauer, Axel [1 ]
Kirchmair, Rudolf [1 ]
Marschang, Peter [1 ,2 ]
Theurl, Markus [1 ]
机构
[1] Med Univ Innsbruck, Univ Hosp Internal Med Cardiol & Angiol, Anichstr 35, A-6020 Innsbruck, Austria
[2] Cent Hosp Bolzano, Dept Internal Med, Via Lorenz Boehler 5, I-39100 Bolzano, Italy
关键词
atherosclerosis; ultrasound; biomarker; preventive medicine; GELATINASE-ASSOCIATED LIPOCALIN; ANKLE-BRACHIAL INDEX; CARDIOVASCULAR EVENTS; ATHEROSCLEROSIS; EXPRESSION; SEVERITY; DISEASE;
D O I
10.3390/jcm9092811
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Inflammation represents a cornerstone in the development of atherosclerosis and early detection is essential to avoid cardiovascular events. Biomarkers like interleukin-1 beta, interleukin-6, or high sensitivity CRP (hs-CRP) have been investigated intensively in this field. Since they have several limitations, additional biomarkers are needed for cardiovascular risk stratification. The acute phase protein, neutrophil gelatinase-associated lipocalin (NGAL), modulates inflammation and is elevated in cardiovascular disease (CVD). Moreover, it contributes to plaque destabilization. Methods: In this prospective, single-center study, we included 323 asymptomatic patients with at least one cardiovascular risk factor or established CVD. NGAL levels were measured in plasma samples using a commercially available ELISA. Carotid, femoral, and total atherosclerotic plaque volumes (PV) were measured using a 3D ultrasound system (Philips iU22). Patients were separated into a low (n= 243) and high (n= 80) total PV group. Results: NGAL was significantly higher in patients with high total PV versus patients with low total PV. The NGAL amplitude for the prediction of high total PV was significantly higher when compared with hs-CRP. A high predictive value could also be observed for patients without established CVD. Conclusion: NGAL seems to be a promising biomarker for the identification of asymptomatic patients with atherosclerotic disease.
引用
收藏
页码:1 / 12
页数:13
相关论文
共 50 条
  • [1] Measurement of Carotid Plaque Volume by 3D Ultrasound
    Al-Mohanna, Khalid
    Hossain, Murad
    Khosravi, Abtin
    Zhao, Limin
    Fischell, Jonathan
    Kowalowski, Gregory
    Sikdar, Siddhartha
    Lal, Brajesh K.
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (06) : 54S - 55S
  • [2] Semiautomatic Quantification of Carotid Plaque Volume With 3D Ultrasonography
    Lal, Brajesh K.
    Khan, Amir A.
    Koudelka, Christian
    Zhao, Limin
    Dux, Moira
    Goldstein, Carly B.
    JOURNAL OF VASCULAR SURGERY, 2016, 63 (06) : 186S - 186S
  • [3] 3D ultrasound analysis of carotid plaque volume and surface morphology
    Fenster, A.
    Blake, C.
    Gyacskov, Igor
    Landry, A.
    Spence, J. D.
    ULTRASONICS, 2006, 44 (e153-e157) : E153 - E157
  • [4] Plaque Volume of Carotid Endarterectomy Specimens Measured by 3D Ultrasound Technology
    Kumar, Anirudh
    Yang, Eric Y.
    Brunner, Gerd
    Murray, Tyler O.
    Virani, Salim S.
    Garami, Zsolt
    Ballantyne, Christie M.
    Morrisett, Joel D.
    Nambi, Vijay
    JACC-CARDIOVASCULAR IMAGING, 2016, 9 (09) : 1118 - 1119
  • [5] Quantification of carotid plaque volume measurements using 3D ultrasound imaging
    Landry, A
    Spence, JD
    Fenster, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (06): : 751 - 762
  • [6] Reliability of tomographic 3D ultrasound in measuring internal carotid artery plaque volume
    Alzahrani, Adel
    Sultan, Salahaden R.
    Aslam, Mohammed
    ACTA RADIOLOGICA, 2023, 64 (11) : 2931 - 2937
  • [7] Correlation of cholesterol efflux capacity with femoral and carotid plaque volume
    Noflatscher, M.
    Hunjadi, M.
    Schreinlechner, M.
    Sommer, P.
    Deutinger, P.
    Lener, D.
    Mair, F.
    Theurl, M.
    Rudolf, K.
    Bauer, A.
    Ritsch, A.
    Marschang, P.
    WIENER KLINISCHE WOCHENSCHRIFT, 2021, 133 (SUPPL 3) : S149 - S149
  • [8] Carotid Artery Diameter Correlates with Plaque Volume but not with Degree of Stenosis
    Phair, Alison
    Ghosh, Jonathan
    McCollum, Charles
    Smith, Craig
    Bowling, Frank
    Rogers, Steven
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2023, 66 (05) : 741 - 742
  • [9] Accelerated Measurement of Carotid Plaque Volume Using Artificial Intelligence Enhanced 3D Ultrasound
    Phair, Alison Shirley
    Carreira, Joao
    Bowling, Frank Lee
    Ghosh, Jonathan
    Smith, Craig
    Rogers, Steven Kristofor
    ANNALS OF VASCULAR SURGERY, 2024, 98 : 317 - 324
  • [10] ULTRASOUND MORPHOLOGY OF CAROTID PLAQUE AND ITS LINK WITH LIPID: PROTEIN CONTENT AND 3D MICROSTRUCTURE OF THE PLAQUE
    Khattab, A.
    Streletz, L.
    Wertheim, D.
    Ali, I
    Wijesinghe, L.
    Jupp, B.
    Thavanesan, K.
    Gale, D.
    Liddell, J.
    Campell, P.
    INTERNATIONAL JOURNAL OF STROKE, 2017, 12 : 57 - 57