Complete heparin-coated cardiopulmonary bypass and low heparin dose reduce complement and granulocyte activation

被引:26
|
作者
Ovrum, E
Fosse, E
Mollnes, TE
Holen, EA
Tangen, G
Abdelnoor, M
Ringdal, MAL
Oystese, R
Venge, P
机构
[1] Department of Cardiac Surgery and Anesthesiology, Oslo Heart Center, Oslo
[2] Surgical Department A, Rikshospitalet, Oslo
[3] Department of Immunology and Transfusion Medicine, Nordland Central Hospital, University of Tromsø
[4] Department of Clinical Chemistry, Uppsala University Hospital
关键词
cardiopulmonary bypass; heparin-coated; complement; granulocytes;
D O I
10.1016/S1010-7940(96)80266-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Complete heparin-coated extracorporeal circuits, including cardiotomy reservoir, have recently become available for routine cardiac surgery. The effects on complement and granulocyte activation using a heparin-coated circuit in combination with reduced systemic heparinization (activated clotting time (ACT) > 250 s) were studied in 33 patients undergoing elective first time myocardial revascularization. The patients were prospectively randomized either to a heparin-coated group (Group H, n = 17), or to a control group (Group C, n = 16)treated with an identical uncoated circuit and full heparin dose (ACT > 480 s). During cardiopulmonary bypass (CPB) the C3 activation products C3b, iC3b, and C3c (C3bc) and the terminal SC5b-9 complement complex (TCC) increased markedly in both groups compared to baseline, but to a much lesser extent in the heparin-coated group. The maximal increase of C3bc during the operation was a median of 28 arbitrary units (AU)/ml in the heparin-coated group, compared to 45 AU/ml in the nr control group (P = 0.01). Similarly, in Group H the maximal increase of TCC was significantly lower (median 0.8 AU/ml) than the levels recognized in Group C(median 1.9 AU/ml) (P < 0.0001). The release of the granulocyte activation enzymes lactoferrin and myeloperoxidase also increased during CPB in both groups compared to baseline level. The maximal increase of lactoferrin concentration was a median of 229 mu g/l in Group H and significantly lower than 647 mu g/l in the control group (P = 0.0002). As for myeloperoxidase, there were no significant intergroup differences. In conclusion, a complete heparin-coated circuit and low systemic heparinization for CPB in coronary artery surgery were associated with reduced activation of the complement system and less release of lactoferrin. The results indicate improved biocompatibility of this option for extracorporeal circulation.
引用
收藏
页码:54 / 60
页数:7
相关论文
共 50 条
  • [1] REDUCED COMPLEMENT AND GRANULOCYTE ACTIVATION WITH HEPARIN-COATED CARDIOPULMONARY BYPASS
    FOSSE, E
    MOEN, O
    JOHNSON, E
    SEMB, G
    BROCKMEIER, V
    MOLLNES, TE
    FAGERHOL, MK
    VENGE, P
    ANNALS OF THORACIC SURGERY, 1994, 58 (02): : 472 - 477
  • [2] High and low heparin dose with heparin-coated cardiopulmonary bypass: Activation of complement and granulocytes
    Ovrum, E
    Mollnes, TE
    Fosse, E
    Holen, EA
    Tangen, G
    Ringdal, MAL
    Videm, V
    ANNALS OF THORACIC SURGERY, 1995, 60 (06): : 1755 - 1761
  • [3] Heparin-coated circuits reduce complement activation and inflammatory response to cardiopulmonary bypass
    Tamim, M
    Demircin, E
    Guvener, M
    Peker, O
    Yilmaz, M
    PANMINERVA MEDICA, 1999, 41 (03) : 193 - 198
  • [4] Eosinophil granulocyte activation and heparin-coated cardiopulmonary bypass - Reply
    Nilsson, L
    ANNALS OF THORACIC SURGERY, 1996, 61 (03): : 1039 - 1039
  • [5] Eosinophil granulocyte activation and heparin-coated cardiopulmonary
    Ovrum, E
    ANNALS OF THORACIC SURGERY, 1996, 61 (03): : 1038 - 1039
  • [6] Changes in platelet, granulocyte, and complement activation during cardiopulmonary bypass using heparin-coated equipment
    Fukutomi, M
    Kobayashi, S
    Niwaya, K
    Hamada, Y
    Kitamura, S
    ARTIFICIAL ORGANS, 1996, 20 (07) : 767 - 776
  • [7] Changes in platelet, granulocyte, and complement activation during cardiopulmonary bypass using heparin-coated equipment
    Department of Surgery III, Nara Medical College, Kashihara, Nara, Japan
    不详
    ARTIF. ORGANS, 7 (767-776):
  • [8] REDUCED GRANULOCYTE ACTIVATION WITH A HEPARIN-COATED DEVICE IN AN INVITRO MODEL OF CARDIOPULMONARY BYPASS
    VIDEM, V
    NILSSON, L
    VENGE, P
    SVENNEVIG, JL
    ARTIFICIAL ORGANS, 1991, 15 (02) : 90 - 95
  • [9] HEPARIN-COATED EQUIPMENT REDUCES COMPLEMENT ACTIVATION DURING CARDIOPULMONARY BYPASS IN THE PIG
    NILSSON, L
    STORM, KE
    THELIN, S
    BAGGE, L
    HULTMAN, J
    THORELIUS, J
    NILSSON, U
    ARTIFICIAL ORGANS, 1990, 14 (01) : 46 - 48
  • [10] USE OF HEPARIN-COATED CARDIOPULMONARY BYPASS
    JONES, DR
    HILL, RC
    HOLLINGSED, MJ
    STULLKEN, E
    GRAEBER, GM
    GUSTAFSON, RA
    MURRAY, GF
    ANNALS OF THORACIC SURGERY, 1993, 56 (03): : 556 - 558