摘要
A green and sensitive sample separation and purification method coupled with high-performance liquid chromatography(HPLC) was developed for the analysis of chloramphenicol(CAP). One element small molecule alcohol-salt aqueous two-phase system(ATPS) can't effectively adjust the polarity of the system, but binary small molecule alcohol-salt ATPS can adjust the polarity and improve the extraction efficiency of antibiotics. A binary aqueous two-phase system based on 1-propanol+2-propanol and NaH2PO4 system was formed and applied to the separation and purification of trace CAP in real samples. The influence factors on partition behaviors of CAP were discussed, including the types and mass of salts, the volume ratio of alcohol, the pH, temperature and the standing time. The optimal condition was found at pH=5.0, 2.5 g of NaH2PO4, 3.0 mL of 1-propanol and 2-propanol(volume ratio 1:1) and 30 degrees C by using response surface methodology. Under this optimal condition, the extraction efficiency of CAP reached 98.91%, and partition coefficient of CAP was 17.31.
引用
收藏
页码:209 / 215
页数:7
相关论文
共 50 条
  • [1] Separation/Extraction/Detection of Chloramphenicol Using Binary Small Molecule Alcohol-Salt Aqueous Two-phase System Coupled with High-performance Liquid Chromatography
    Donggang Guo
    Liang Ni
    Liang Wang
    Li Shao
    Chemical Research in Chinese Universities, 2019, 35 : 209 - 215
  • [2] Separation and determination of tetracycline hydrochloride in real water samples using binary small molecule alcohol-salt aqueous two-phase system coupled with high-performance liquid chromatography
    Guo, Dong-gang
    Ni, Liang
    Wang, Liang
    Shao, Li
    CHIRALITY, 2019, 31 (09) : 658 - 668
  • [3] Separation, concentration and determination of chloramphenicol in environment and food using an ionic liquid/salt aqueous two-phase flotation system coupled with high-performance liquid chromatography
    Han, Juan
    Wang, Yun
    Yu, Cuilan
    Li, Chunxiang
    Yan, Yongsheng
    Liu, Yan
    Wang, Liang
    ANALYTICA CHIMICA ACTA, 2011, 685 (02) : 138 - 145
  • [4] Extraction and determination of chloramphenicol in feed water, milk, and honey samples using an ionic liquid/sodium citrate aqueous two-phase system coupled with high-performance liquid chromatography
    Han, Juan
    Wang, Yun
    Yu, Cui-lan
    Yan, Yong-sheng
    Xie, Xue-qiao
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (03) : 1295 - 1304
  • [5] Extraction and determination of chloramphenicol in feed water, milk, and honey samples using an ionic liquid/sodium citrate aqueous two-phase system coupled with high-performance liquid chromatography
    Juan Han
    Yun Wang
    Cui-lan Yu
    Yong-sheng Yan
    Xue-qiao Xie
    Analytical and Bioanalytical Chemistry, 2011, 399 : 1295 - 1304
  • [6] Synchronized separation, concentration and determination of trace chloramphenicol, thiamphenicol and florfenicol in food by using polyoxyethylene cetyl ether-salt aqueous two-phase system coupled with high-performance liquid chromatography
    Wang, Tingting
    Zhang, Dan
    Zhang, Ziliang
    Han, Juan
    Wang, Yun
    Tang, Xu
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2016, 13 (10) : 1759 - 1765
  • [7] Synchronized separation, concentration and determination of trace chloramphenicol, thiamphenicol and florfenicol in food by using polyoxyethylene cetyl ether-salt aqueous two-phase system coupled with high-performance liquid chromatography
    Tingting Wang
    Dan Zhang
    Ziliang Zhang
    Juan Han
    Yun Wang
    Xu Tang
    Journal of the Iranian Chemical Society, 2016, 13 : 1759 - 1765
  • [8] Separation, concentration and determination of trace chloramphenicol in shrimp from different waters by using polyoxyethylene lauryl ether-salt aqueous two-phase system coupled with high-performance liquid chromatography
    Lu, Yang
    Yao, Hui
    Li, Chuang
    Han, Juan
    Tan, Zhenjiang
    Yan, Yongsheng
    FOOD CHEMISTRY, 2016, 192 : 163 - 170
  • [9] Novelty aqueous two-phase extraction system based on ionic liquid for determination of sulfonamides in blood coupled with high-performance liquid chromatography
    Yu Wei
    Li Kai
    Liu Zhongling
    Zhang Hanqi
    Jin Xiangqun
    MICROCHEMICAL JOURNAL, 2018, 136 : 263 - 269
  • [10] Determination of sulfonamides in blood using acetonitrile-salt aqueous two-phase extraction coupled with high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry
    Yu, Wei
    Liu, Zhongling
    Gao, Shiqian
    Cui, Shusen
    Yang, Xiao
    Qiu, Wei
    Zhang, Hanqi
    Yu, Aimin
    Huan, Yanfu
    ANALYTICAL METHODS, 2013, 5 (21) : 5983 - 5989