Biomechanical test comparing the load to failure of the biodegradable meniscus arrow versus meniscal suture

被引:58
|
作者
Song, EK [1 ]
Lee, KB [1 ]
机构
[1] Chonnam Univ Hosp, Dept Orthopaed, Kwangju, South Korea
来源
ARTHROSCOPY | 1999年 / 15卷 / 07期
关键词
meniscal repair; biodegradable meniscus arrow; biomechanical test; failure strength;
D O I
10.1016/S0749-8063(99)70004-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The biodegradable Meniscus Arrow (Bionx, Blue Bell, PA) is a newly introduced method for repair of meniscal injury. However, because of a lack of studies, there is still little understanding of its biomechanical behavior. Biomechanical test was carried out to evaluate the load to failure and failure modes of the Meniscus Arrow and to compare the results with those of three traditionally used methods. Thirty-five lateral menisci obtained from Yorkshire pigs were incised longitudinally, simulating a peripheral longitudinal tear, and were repaired by means of Meniscus Arrows (one-point and two-point fixation), as well as with the techniques of knot-end, horizontal, and vertical suture using No. 1 PDS II monofilament suture. Tensile strength testing was performed according to each repair method with the Instron tensometer (Model No. 5569; Instron, Canton, MA) and its results were analyzed using a computerized statistical program. The average maximal tensile strengths were 113.9 +/- 14.6 N in vertical suture, 75.1 +/- 18.4 N in horizontal suture, 53.9 +/- 6.4 N in knot-end suture, 38.3 +/- 4.3 N in one-point fixation Meniscus Arrow repair, and 56.5 +/- 3.5 N in two-paint fixation Meniscus Arrow repair. The initial failure strength for two-point fixation Meniscus Arrow repair is comparable to that of a knot-end suture. Following the results of this study, meticulous caution should be taken when meniscal tears are repaired with Meniscus Arrows.
引用
收藏
页码:726 / 732
页数:7
相关论文
共 40 条
  • [1] Failure strengths of suture versus biodegradable arrow for meniscal repair: An in vitro study
    Dervin, GF
    Downing, KJW
    Keene, GCR
    McBride, DG
    ARTHROSCOPY, 1997, 13 (03): : 296 - 300
  • [2] Failure strength of a new meniscus arrow repair technique: Biomechanical comparison with horizontal suture
    AlbrechtOlsen, P
    Lind, T
    Kristensen, G
    Falkenberg, B
    ARTHROSCOPY, 1997, 13 (02): : 183 - 187
  • [3] Failure of a biodegradable meniscal arrow - A case report
    Hutchinson, MR
    Ash, SA
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (01): : 101 - 103
  • [4] Failure strengths of suture vs. biodegradable arrow and staple for meniscal repair: an in vitro study
    Walsh, SP
    Evans, SL
    O'Doherty, DM
    Barlow, IW
    KNEE, 2001, 8 (02): : 151 - 156
  • [5] Aseptic synovitis after meniscal repair using the biodegradable meniscus arrow
    Song, EK
    Lee, KB
    Yoon, TR
    ARTHROSCOPY, 2001, 17 (01): : 77 - 80
  • [6] Biomechanical Comparison of the Simple Suture Technique, Meniscal Matrix-Assisted Repair, and a Novel Meniscus Cap Suture Technique for Complex Meniscal Repair
    Ciemniewska-Gorzela, Kinga
    Gorecki, Jan
    Wojtkowiak, Dominik
    Henklewski, Radomir
    Zak-Palczynska, Katarzyna
    Murray, James
    Talaska, Krzysztof
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (12)
  • [7] Load to failure of common meniscal repair techniques: Effects of suture technique and suture material
    Post, WR
    Akers, SR
    Kish, V
    ARTHROSCOPY, 1997, 13 (06): : 731 - 736
  • [8] A biomechanical comparison of the FasT-Fix meniscal repair suture system and the RapidLoc device in cadaver meniscus
    Kocabey, Y
    Chang, HC
    Brand, JC
    Nawab, A
    Nyland, J
    Caborn, DNM
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (04): : 406 - 413
  • [9] Suture Repair versus Arrow Repair for Symptomatic Meniscus Tears of the Knee: A Systematic Review
    Ayeni, Olufemi
    Peterson, Devin
    Chan, Kevin
    Javidan, Ashkan
    Gandhi, Rajiv
    JOURNAL OF KNEE SURGERY, 2012, 25 (05) : 397 - 402
  • [10] Biomechanical comparison of the FasT-Fix meniscal repair suture system with vertical mattress sutures and meniscus arrows
    Borden, P
    Nyland, J
    Caborn, DNM
    Pienkowski, D
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (03): : 374 - 378