Calibration of Laser Beam Direction for Inner Diameter Measuring Device

被引:29
|
作者
Yang, Tongyu [1 ]
Wang, Zhong [1 ]
Wu, Zhengang [1 ]
Li, Xingqiang [1 ]
Wang, Lei [1 ]
Liu, Changjie [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin 300072, Peoples R China
关键词
inner diameter measurement; laser beams; direction calibration; laser displacement sensor; PERFORMANCE; PARAMETERS; INSPECTION; ALGORITHM; SENSOR; SYSTEM;
D O I
10.3390/s17020294
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The laser triangulation method is one of the most advanced methods for large inner diameter measurement. Our research group proposed a kind of inner diameter measuring device that is principally composed of three laser displacement sensors known to be fixed in the same plane measurement position. It is necessary to calibrate the direction of the laser beams that are emitted by laser displacement sensors because they do not meet the theoretical model accurately. For the purpose of calibrating the direction of laser beams, a calibration method and mathematical model were proposed. The inner diameter measuring device is equipped with the spindle of the machine tool. The laser beams rotate and translate in the plane and constitute the rotary rays which are driven to scan the inner surface of the ring gauge. The direction calibration of the laser beams can be completed by the sensors' distance information and corresponding data processing method. The corresponding error sources are analyzed and the validity of the method is verified. After the calibration, the measurement error of the inner diameter measuring device reduced from +/- 25 mu m to +/- 15 mu m and the relative error was not more than 0.011%.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Calibration of laser beam direction for optical coordinate measuring system
    Chao, Bi
    Yong, Liu
    Fang Jian-guo
    Xia, Guo
    Lv Lai-peng
    Pu, Dong
    MEASUREMENT, 2015, 73 : 191 - 199
  • [2] Two methods for measuring laser beam diameter
    Marshall, Wesley J.
    JOURNAL OF LASER APPLICATIONS, 2010, 22 (04) : 132 - 136
  • [3] Calibration of laser beam-direction for point laser sensors
    Lu, Ke-Qing
    Wang, Wen
    Chen, Zi-Chen
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2010, 18 (04): : 880 - 886
  • [4] Device for measuring laser beam intensity
    Margaryan, HL
    Aroutiounian, VM
    Meliksetyan, VA
    LIQUID CRYSTALS VII, 2003, 5213 : 278 - 282
  • [5] TECHNIQUE FOR MEASURING LASER BEAM PROPAGATION DIRECTION FLUCTUATIONS
    KURIGER, WL
    APPLIED OPTICS, 1971, 10 (11): : 2462 - &
  • [6] DETERMINATION OF DIRECTION OF LASER BEAM BY MEASURING POLARIZATION OF REFLECTED BEAM.
    Lobachev, M.I.
    Rabinovich, E.M.
    Tuchin, V.V.
    Instruments and experimental techniques New York, 1980, 23 (5 pt 2): : 1276 - 1278
  • [7] DETERMINATION OF DIRECTION OF LASER-BEAM BY MEASURING POLARIZATION OF REFLECTED BEAM
    LOBACHEV, MI
    RABINOVICH, EM
    TUCHIN, VV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1980, 23 (05) : 1276 - 1278
  • [8] SIMPLE METHOD OF MEASURING FLUCTUATIONS IN DIAMETER OF A LASER-BEAM
    LOBACHEV, MI
    RABINOVICH, EM
    TUCHIN, VV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1977, 20 (04) : 1174 - 1176
  • [9] Calibration of beam direction of laser displacement sensor based on spherical target
    Bi, Chao
    Fang, Jian-Guo
    Liu, Jing-Liang
    Liu, Yong
    Li, Cheng-Wei
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2015, 23 (03): : 678 - 685
  • [10] Robustness evaluation of the non-contact inner diameter measuring device with micrometer order
    Mitsunari, Toshiyasu
    Okamoto, Yuji
    Nozawa, Itta
    Yamazaki, Kazunori
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS V, 2018, 10819