A high-throughput LC-MS/MS method for the measurement of the bile acid/salt content in microbiome-derived sample sets

被引:3
|
作者
Horvath, Thomas D. [1 ,2 ]
Haidacher, Sigmund J. [1 ,2 ]
Hoch, Kathleen M. [1 ,2 ]
Auchtung, Jennifer M. [3 ]
Haag, Anthony M. [1 ,2 ]
机构
[1] Baylor Coll Med, Dept Pathol & Immunol, 1 Baylor Plaza, Houston, TX 77030 USA
[2] Texas Childrens Hosp, Texas Childrens Microbiome Ctr, 1102 Bates Ave, Houston, TX 77030 USA
[3] Univ Nebraska, Food Sci & Technol Dept, 1400 R St, Lincoln, NE 68588 USA
关键词
Bioanalytical chemistry; High-throughput sample analysis; High-performance liquid chromatography; LC-MS/MS; Microbiome; Microbiology;
D O I
10.1016/j.mex.2020.100951
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Due to the physicochemical properties of bile acids/salts (i.e., hydrophobic and ionizable), the application of reverse-phase liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based methods are ideally suited for the measurement of these compounds in a host of microbiologically-relevant matrices. Here, we provide a detailed bioanalytical protocol that contains several modifications of a method previously described by Wegner et al. [1] . Briefly, this modified method exhibits the following advantages for the measurement of cholic acid (CA), taurocholic acid (TCA), and deoxycholic acid (DCA) in microbiome-relevant sample matrices: i) fecal sample processing has been streamlined by the elimination of lyophilization and manual homogenization steps; ii) the Sciex 6500 QTRAP hybrid triple-quadrupole/linear ion trap mass spectrometer has sufficient sensitivity to perform the measurement of bile acids/salts in negative ion mode - ammonium adducts of bile acids/salts are not required for detection; and, iii) assay throughput has been boosted by more than 5-fold by shortening the chromatographic duty cycle of a single sample injection from 45 min to 8.4 min. Recently, the method was used to perform 508 sequential injections (72 calibration standards, 52 blank-internal standard sample, and 368 MiniBioReactor Array (MBRA)-derived samples) from four separate batches over a 4-day time period. (C) 2020 The Authors. Published by Elsevier B.V.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Fast LC for high-throughput LC-MS
    Wehr, T
    LC GC NORTH AMERICA, 2003, : 75 - 78
  • [2] Fast LC for high-throughput LC-MS
    Wehr, T
    LC GC NORTH AMERICA, 2002, 20 (01) : 40 - +
  • [3] An Automated High-Throughput Sample Preparation Protocol for LC-MS/MS Analysis of Glycopeptides
    Arul, Albert-Baskar
    Park, Jong-Moon
    Lee, Hookeun
    Baek, Jeong-Heum
    Jeon, Jongho
    Ji, Eunhee
    Oh, Jae Won
    Kim, Kwang Pyo
    CURRENT PROTEOMICS, 2016, 13 (01) : 55 - 60
  • [4] Automated sample preparation and LC-MS for high-throughput ADME quantification
    O'Connor, D
    CURRENT OPINION IN DRUG DISCOVERY & DEVELOPMENT, 2002, 5 (01) : 52 - 58
  • [5] Development and validation of a high-throughput LC-MS/MS assay for routine measurement of molecular ceramides
    Kauhanen, Dimple
    Sysi-Aho, Marko
    Koistinen, Kaisa M.
    Laaksonen, Reijo
    Sinisalo, Juha
    Ekroos, Kim
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (13) : 3475 - 3483
  • [6] Simultaneous detection of salivary cortisol and cortisone using an automated high-throughput sample preparation method for LC-MS/MS
    Fariha, Ramisa
    Jabrah, Mohannad
    Hill, Collin
    Spooner, Adam
    Deshpande, Prutha
    Tripathi, Anubhav
    SLAS TECHNOLOGY, 2022, 27 (04): : 237 - 246
  • [7] High-throughput LC-MS/MS analysis of sirolimus in whole blood
    Wallemacq, P
    Vanbinst, R
    Asta, S
    Cooper, D
    THERAPEUTIC DRUG MONITORING, 2003, 25 (04) : 534 - 534
  • [8] Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS
    Xu, Raymond Naxing
    Fan, Leimin
    Rieser, Matthew J.
    El-Shourbagy, Tawakol A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (02) : 342 - 355
  • [9] High-throughput identification of IMCD proteins using LC-MS/MS
    Pisitkun, T
    Bieniek, J
    Tchapyjnikov, D
    Wang, GH
    Wu, WW
    Shen, RF
    Knepper, MA
    PHYSIOLOGICAL GENOMICS, 2006, 25 (02) : 263 - 276
  • [10] Development of an automated high-throughput sample preparation protocol for LC-MS/MS analysis of glycated peptides
    Jeon, Jongho
    Yang, Jiwon
    Park, Jong-Moon
    Han, Na-Young
    Lee, Yeong-Bae
    Lee, Hookeun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1092 : 88 - 94