Procedure analysis of UHVDC commutation failure

被引:12
|
作者
Wang, Chenqing [1 ]
Zhang, Chi [1 ]
Kong, Xiangping [1 ]
Li, Peng [1 ]
Yuan, Yubo [1 ]
机构
[1] State Grid Jiangsu Elect Power CO LTD, Res Inst, 1 Paweier Rd, Nanjing, Jiangsu, Peoples R China
来源
关键词
failure (mechanical); invertors; power transmission control; HVDC power transmission; power transmission faults; commutation; failure analysis; relay protection; power transmission reliability; UHVDC commutation failure; UHVDC inverter side; inverter commutation failures; Taizhou UHVDC inverter; commutation failure stage; commutation failure recovery stage; commutation failure valve number; commutation failure process analysis; identification;
D O I
10.1049/joe.2018.8451
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
There may be a commutation failure during a fault or start-up of the UHVDC inverter side. The law of commutation failure process in UHVDC converter is studied here. First, the cause of inverter commutation failures is briefly introduced. Then, the general law for the bridge arm conduction of the inverter in the process of the commutation failure is revealed. Finally, the system debugging recorded data of some commutation failures of Taizhou UHVDC inverter in China is used to verify the law. Research shows that the commutation failure will go through three stages which has obvious features: (i) the commutation failure stage, (ii) the bypass circuit formation stage, and (iii) the commutation failure recovery stage. In the last stage, the AC currents of two conducted phases increase instantly in opposite directions, which are easy to recognise. In the second stage, only the DC current increases, and the AC currents equal 0 approximately. Because of the three stages, the commutation failure valve number is easily recognised. The study on the law of commutation failure process lay the foundation for commutation failure process analysis and identification for relay protection.
引用
收藏
页码:3132 / 3134
页数:3
相关论文
共 50 条
  • [1] Analysis of the commutation failure process and a study on the influence of operation parameters on a UHVDC system
    Han P.
    Tong Q.
    Yang W.
    Chen Z.
    Sun H.
    Zhang Y.
    Tong, Qingyang (tqyhfut0325@163.com), 1600, Power System Protection and Control Press (49): : 25 - 34
  • [2] Commutation Failure Analysis and Prevention of UHVDC System With Hierarchical Connection Considering Voltage Harmonics
    Wang, Lingrao
    Yao, Wei
    Xiong, Yongxin
    Shi, Zhongtuo
    Wen, Jinyu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (04) : 3142 - 3154
  • [3] Simulation Analysis of Voltage Fluctuation at the Sending End of UHVDC System Caused by Commutation Failure
    Niu, Yukun
    Wen, Jun
    Wang, Shujie
    Ma, Limin
    2021 3RD ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2021), 2021, : 15 - 19
  • [4] Analysis on Commutation Failure and DC Differential Protection Unwanted Action of Yunnan-Guangdong UHVDC
    Xie Huifan
    Yang Guangyuan
    Peng Guangqiang
    Chen Xiaopeng
    Chen Yan Zhou
    Feng Dong
    Wang Qi
    Chen Yanzhou
    ADVANCED RESEARCH IN MATERIAL SCIENCE AND MECHANICAL ENGINEERING, PTS 1 AND 2, 2014, 446-447 : 784 - 789
  • [5] Commutation failure control and recovery strategy of UHVDC with hierarchical connection mode
    Wang S.
    Wen J.
    He D.
    Geng X.
    Tan M.
    Han M.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (02): : 172 - 179
  • [6] Simulation on Power Characteristic of UHVDC During Commutation Failure and DC Block
    Li, Fanfan
    Chen, Qian
    Lin, Xue
    Ju, Ping
    Xiong, Haoqing
    Shan, Xin
    Wang, Bo
    Qin, Chuan
    Zhao, Jian
    Jiang, Meng
    2017 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC), 2017, : 446 - 451
  • [7] Prevention Method for Commutation Failure of UHVDC Based on Interelectrode Coupling Characteristics
    Li X.
    Fu Y.
    Zhang Q.
    Lin S.
    Lei X.
    Xu R.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (23): : 170 - 177
  • [8] Commutation Failure Impacted by Harmonics in UHVDC Split Connection Grid System
    Jin X.
    Yang W.
    Xu Y.
    Yang, Wankai (wankai@epri.sgcc.com.cn), 1600, Power System Technology Press (45): : 3763 - 3771
  • [9] Coordinated Control of Commutation Failure Prevention for UHVDC Hierarchical Connection to AC Grid
    Xin J.
    Shu Z.
    Tan Y.
    Wang G.
    Yao W.
    Ai X.
    Wen J.
    Cheng S.
    Dianwang Jishu/Power System Technology, 2019, 43 (10): : 3543 - 3551
  • [10] Study on the Impact of Commutation Failure on AC voltage of Rectifier-side in UHVDC
    Li Xin-nian
    Liu Yao
    Li Tao
    Chen Shu-yong
    Lei Xiao
    Lin Shao-bo
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014,