Sonographic evaluation of breast nodules: comparison of conventional, real-time compound, and pulse-inversion harmonic images

被引:23
|
作者
Seo, BK
Oh, YW
Kim, HR
Kim, HW
Kang, CH
Lee, NJ
Kim, JH
Park, BJ
Cho, KR
Lee, JY
Lee, KY
Bae, JW
机构
[1] Univ Korea Hosp, Dept Diagnost Radiol, Seoul, South Korea
[2] Univ Korea Hosp, Dept Gen Surg, Seoul, South Korea
[3] Korea Univ, Dept Prevent Med, Seoul, South Korea
[4] Inje Univ Hosp, Dept Diagnost Radiol, Seoul, South Korea
关键词
breast; US; ultrasound (US); ultrasound; (US); technology; comparative studies;
D O I
10.3348/kjr.2002.3.1.38
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the use of conventional, real-time compound, and pulse-inversion harmonic imaging in the evaluation of breast nodules. Materials and Methods: Fifty-two breast nodules were included in this study, conducted between May and December 2000, in which conventional, real-time compound, and pulse-inversion harmonic images were obtained in the same plane. Three radiologists, each blinded to the interpretations of the other two, evaluated the findings, characterizing the lesions and ranking the three techniques from grade 1, the worst, to grade 3, the best. Lesion conspicuity was assessed, and lesions were also characterized in terms of their margin, clarity of internal echotexture, and clarity of posterior echo pattern. The three techniques were compared using Friedman's test, and interobserver agreement in image interpretation was assessed by means of the intraclass correlation coefficient. Results: With regard to lesion conspicuity, margin, and internal echotexture of the nodules, real-time compound imaging was the best technique (p < 0.05); in terms of posterior echo pattern, the best was pulse-inversion harmonic imaging (p < 0.05). Real-time compound and pulse inversion harmonic imaging were better than conventional sonography in all evaluative aspects. Interobserver agreement was greater than moderate. Conclusion: Real-time compound and pulse-inversion harmonic imaging procedures are superior to conventional sonography in terms of both lesion conspicuity and the further characterization of breast nodules. Real-time compound imaging is the best technique for evaluation of the margin and internal echotexture of nodules, while pulse-inversion harmonic imaging is very effective for the evaluation of the posterior echo patterns.
引用
收藏
页码:38 / 44
页数:7
相关论文
共 29 条
  • [1] Ultrasound evaluation of normal and abnormal fetuses: Comparison of conventional, tissue harmonic, and pulse-inversion harmonic imaging techniques
    Ryu, JA
    Kim, B
    Kim, S
    Yang, SH
    Choi, MH
    Ahn, HS
    KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (03) : 184 - 190
  • [2] Image quality of gallbladder lesions: Comparison of conventional sonographic, conventional tissue harmonic, and pulse inversion tissue harmonic images
    Lim, HK
    Lee, W
    Lee, JY
    Jang, H
    Kim, E
    Kim, SH
    RADIOLOGY, 1999, 213P : 381 - 381
  • [3] Variable breast conditions - Comparison of conventional and real-time compound ultrasonography
    Kwak, JY
    Kim, EK
    You, JK
    Oh, KK
    JOURNAL OF ULTRASOUND IN MEDICINE, 2004, 23 (01) : 85 - 96
  • [4] Golay-Encoded Pulse-Inversion Subtraction for Real-Time Ultrasound Monitoring of HIFU Therapy
    Lai, Guan-Heng
    Li, Pai-Chi
    Shen, Che-Chou
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 127 - 130
  • [5] Comparison of conventional sonography, real-time compound sonography, tissue harmonic sonography, and tissue harmonic compound sonography of abdominal and pelvic lesions
    Oktar, SÖ
    Yücel, C
    Özdemir, H
    Ulutürk, A
    Isik, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (05) : 1341 - 1347
  • [6] Ultrasonographic evaluation of focal hepatic lesions: Comparison of pulse inversion harmonic, tissue harmonic, and conventional imaging techniques
    Jang, HJ
    Lim, HK
    Lee, WJ
    Kim, SH
    Kim, KA
    Kim, EY
    JOURNAL OF ULTRASOUND IN MEDICINE, 2000, 19 (05) : 293 - 299
  • [7] Real-time spatial compound imaging of the breast: Clinical evaluation of masses
    Merritt, CR
    Piccoli, CW
    Forsberg, F
    Wilkes, AN
    Cavanaugh, BC
    Lee, SG
    RADIOLOGY, 2000, 217 : 491 - 492
  • [8] Comparison of conventional ultrasound and real-time spatial compound Imaging in evaluation of patients with severe Peyronie's disease
    Bertolotto, M.
    Perrone, R.
    Bucci, S.
    Zappetti, R.
    Coss, M.
    ACTA RADIOLOGICA, 2008, 49 (05) : 596 - 601
  • [9] Ultrasound evaluation of normal and abnormal fetuses: Comparison of conventional, 2D harmonic, and pulse inversion harmonic imaging techniques
    Kim, Chan Kyo
    Kim, Bohyun
    Choi, Moon Hae
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):
  • [10] The benefits of comparing conventional sonography, real-time spatial compound sonography, tissue harmonic sonography, and tissue harmonic compound sonography of hepatic lesions
    Yen, Chin-Lan
    Jeng, Chin-Ming
    Yang, Sien-Sing
    CLINICAL IMAGING, 2008, 32 (01) : 11 - 15