Modular tied eccentrically braced frames for improved seismic response of tall buildings

被引:16
|
作者
Chen, L. [1 ]
Tremblay, R. [1 ]
Tirca, L. [2 ]
机构
[1] Ecole Polytech Montreal, Dept Civil Geol & Min Engn, 2500 Chemin Polytech, Montreal, PQ H3T 1J4, Canada
[2] Concordia Univ, Dept Bldg Civil & Environm Engn, 1515 St Catherine W, Montreal, PQ H3G 1M8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Eccentrically braced frame; Tied braced frame; Modular; Storey drift; Residual drift; DESIGN PROCEDURE; BEHAVIOR; LINKS;
D O I
10.1016/j.jcsr.2019.01.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Two alternative braced frame configurations are examined to improve the vertical distribution of seismic storey drifts and inelastic demands in multi-storey steel eccentrically braced frames (EBFs): the tied braced frame (TBF) system and a modular tied-braced frame (M-TBF) system. In TBFs, the concentration of inelastic deformation is prevented by connecting all ductile links over the frame height with vertical tie members. In the M-TBF configuration, the ties are interrupted at one or more locations along the frame height to reduce member forces while achieving the same objective as the TBF. The performance of each bracing system is investigated through nonlinear response history analysis for 8-.16-, and 24-storey prototype building structures. For the 16-storey building, two M-TBF configurations are examined, two 8-storey modules and four 4-storey modules, to investigate the influence of this parameter. The analysis results show that the TBFs exhibited smaller and more uniform storey drifts and residual drifts at the expense of high axial force demands in the tie members. Soft-storey response could also be mitigated with M-TBFs, but member forces diminished significantly when adopting a modular tied braced frame configuration, which led to a reduction in the required steel tonnage with limited increases in peak and residual drift demands. Performance assessment using incremental dynamic analysis showed that the 16-storey EBF could not pass the FEMA P695 collapse safety criteria whereas all tied braced frames could exhibit satisfactory performance. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:370 / 384
页数:15
相关论文
共 50 条
  • [1] Seismic response of tied and trussed eccentrically braced frames
    Ghersi, A
    Neri, F
    Rossi, PP
    Perretti, A
    BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2000, : 495 - 502
  • [2] SEISMIC RESPONSE OF ECCENTRICALLY BRACED FRAMES
    JAIN, AK
    GOEL, SC
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1980, 106 (04): : 843 - 860
  • [3] SEISMIC RESPONSE OF ECCENTRICALLY BRACED FRAMES
    Jain, Ashok K.
    Goel, Subhash C.
    1980, 106 (04): : 843 - 860
  • [4] SEISMIC RESPONSE OF ECCENTRICALLY BRACED TALL BUILDING
    CELEBI, M
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1993, 119 (04): : 1188 - 1205
  • [5] SEISMIC ECCENTRICALLY BRACED FRAMES
    POPOV, EP
    ENGELHARDT, MD
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1988, 10 : 321 - 354
  • [6] Seismic Overstrength in Braced Frames of Modular Steel Buildings
    Annan, C. D.
    Youssef, M. A.
    El Naggar, M. H.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2009, 13 (01) : 1 - 21
  • [7] A seismic design of eccentrically braced frames
    Kober, Helmuth, Jr.
    Stefanescu, Bogdan
    STEEL - A NEW AND TRADITIONAL MATERIAL FOR BUILDING, 2006, : 537 - +
  • [8] Seismic behaviour of eccentrically braced frames
    Bosco, M.
    Rossi, P. P.
    ENGINEERING STRUCTURES, 2009, 31 (03) : 664 - 674
  • [9] Design and seismic response of shear critical eccentrically braced frames
    Koboevic, S
    Redwood, R
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1997, 24 (05) : 761 - 771
  • [10] A review of Research on Seismic Performance of Steel Eccentrically Braced Frames in Prefabricated Buildings
    Sun, Haisu
    Shi, Qiang
    Wang, Xinwu
    Li, Tong
    Zhao Zhangshuo
    6TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND CIVIL ENGINEERING, 2020, 455