A Temperature-Risk and Energy-Saving Evaluation Model for Supporting Energy-Saving Measures for Data Center Server Rooms

被引:0
|
作者
Sasakura, Kosuke [1 ]
Aoki, Takeshi [1 ]
Komatsu, Masayoshi [1 ]
Watanabe, Takeshi [1 ]
机构
[1] NTT Facil INC, Koto Ku, Tokyo 1350007, Japan
关键词
temperature prediction; energy simulation; baseline; machine learning; data center; server room; temperature environment; energy saving; continuous and reliable operation;
D O I
10.3390/en13195222
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
As data centers have become increasingly important in recent years their operational management must attain higher efficiency and reliability. Moreover, the power consumption of a data center is extremely large, and it is anticipated that it will continue to increase, so energy saving has become an urgent issue concerning data centers. In the meantime, the environment of the server rooms in data centers has become complicated owing to the introduction of virtualization technology, the installation of high-heat density information and communication technology (ICT) equipment and racks, and the diversification of cooling methods. It is very difficult to manage a server room in the case of such a complicated environment. When energy-saving measures are implemented in a server room with such a complicated environment, it is important to evaluate "temperature risks" in advance and calculate the energy-saving effect after the measures are taken. Under those circumstances, in this study, two prediction models are proposed: a model that predicts the rack intake temperature (so that the temperature risk can be evaluated in support of energy-saving measures implemented in the server room) and a model that evaluates the energy-saving effect (in relation to a baseline). Specifically, the models were constructed by using machine learning. The first constructed model evaluates the temperature risk in a verification room in advance, and it was confirmed that the model can evaluate the risk beforehand with high accuracy. The second constructed model-"baseline model" hereafter-supports energy-saving measures, and it was confirmed that the model can calculate the baseline (energy consumption) with high accuracy as well. Moreover, the effect of proposal process of energy-saving measures in the verification room was verified by using the two proposed models. In particular, the effectiveness of the model for evaluating temperature risk in advance and that of a technology for visualizing the energy-saving effect were confirmed.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] ENERGY-SAVING MEASURES
    不详
    ENERGY WORLD, 1977, (42): : 9 - 12
  • [2] PERFORMANCE EVALUATION OF ENERGY-SAVING MEASURES
    PIETTE, MA
    ANDERSSON, B
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1988, 30 (06): : 34 - 39
  • [3] ENERGY-SAVING MEASURES IN GREENHOUSES
    VONZABELTITZ, C
    LANDTECHNIK, 1978, 33 (10): : 458 - 459
  • [4] ENERGY-SAVING MEASURES.
    Anon
    1600,
  • [5] Building energy-saving measures
    Huang, Yunfeng
    SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 668 - 671
  • [6] ENERGY-SAVING MEASURES IN STORES
    HARA, M
    KIOKA, I
    KIGUCHI, K
    TOSHIBA REVIEW, 1979, (121): : 36 - 40
  • [7] PERFORMANCE EVALUATION OF ENERGY-SAVING MEASURES.
    Piette, Mary Ann
    Andersson, Brandt
    ASHRAE Journal, 1988, 30 (06) : 34 - 39
  • [8] Energy-Saving in Optical Data Center Networks
    Jiang, Peipei
    Yu, Cunqian
    Peng, Yuhuai
    INFORMATION TECHNOLOGY APPLICATIONS IN INDUSTRY II, PTS 1-4, 2013, 411-414 : 634 - 637
  • [9] Energy Saving Research on Temperature Control in Data Center Server Rooms
    Su, Yang
    Lu, Xiang
    2024 INTERNATIONAL CONFERENCE ON ELECTRONICS, ELECTRICAL AND CONTROL SYSTEM, EECS 2024, 2024, 2800
  • [10] Survey data on energy-saving policies, energy price, crisis and household energy-saving behavior
    Nguyen, Tung Thanh
    Nguyen, Dat Ngoc
    Pham, Huong Thi Lan
    DATA IN BRIEF, 2023, 51