CMUT-based Volumetric Ultrasonic Imaging Array Design for Forward Looking ICE and IVUS Applications

被引:2
|
作者
Tekes, Coskun [1 ]
Zahorian, Jaime [2 ]
Xu, Toby [1 ]
Rashid, Muhammad W. [2 ]
Satir, Sarp [2 ]
Gurun, Gokce [2 ]
Karaman, Mustafa [3 ]
Hasler, Jennifer [2 ]
Degertekin, F. Levent [1 ]
机构
[1] Georgia Inst Technol, George W Woodruff Sch Mech Engn, 771 Ferst Dr, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[3] Univ Isik, Dept Elect Engn, Istanbul, Turkey
来源
MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY | 2013年 / 8675卷
关键词
CMUT; intravascular ultrasound; intracardiac echocardiography; real time; volumetric imaging;
D O I
10.1117/12.2007042
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Designing a mechanically flexible catheter based volumetric ultrasonic imaging device for intravascular and intracardiac imaging is challenging due to small transducer area and limited number of cables. With a few parallel channels, synthetic phased array processing is necessary to acquire data from a large number of transducer elements. This increases the data collection time and hence reduces frame rate and causes artifacts due to tissue-transducer motion. Some of these drawbacks can be resolved by different array designs offered by CMUT-on-CMOS approach. We recently implemented a 2.1-mm diameter single chip 10 MHz dual ring CMUT-on-CMOS array for forward looking ICE with 64-transmit and 56-receive elements along with associated electronics. These volumetric arrays have the small element size required by high operating frequencies and achieve sub mm resolution, but the system would be susceptible to motion artifacts. To enable real time imaging with high SNR, we designed novel arrays consisting of multiple defocused annular rings for transmit aperture and a single ring receive array. The annular transmit rings are utilized to act as a high power element by focusing to a virtual ring shaped line behind the aperture. In this case, image reconstruction is performed by only receive beamforming, reducing total required firing steps from 896 to 14 with a trade-off in image resolution. The SNR of system is improved more than 5 dB for the same frequency and frame rate as compared to the dual ring array, which can be utilized to achieve the same resolution by increasing the operating frequency.
引用
收藏
页数:6
相关论文
共 48 条
  • [1] Fully integrated CMUT-based forward-looking intracardiac imaging for electrophysiology
    Nikoozadeh, Amin
    Wygant, Ira O.
    Linl, Der-Song
    Oralkan, Oemer
    Ergun, Arif Sanli
    Thomenius, Kai
    Dentinger, Aaron
    Wildes, Douglas
    Akopyan, Gina
    Shivkumar, Kalyanam
    Mahajan, Aman
    Stephens, Douglas N.
    Sahn, David
    Khuri-Yakub, Pierre T.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 900 - +
  • [2] Dual-Annular-Ring CMUT Array for Forward-Looking IVUS Imaging
    Guldiken, Rasim
    Zahorian, Jaime
    Balantekin, Mujdat
    Degertekin, F. Levent
    Tekes, Coskun
    Sisman, Alper
    Karaman, Mustalla
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 698 - +
  • [3] Forward-looking IVUS imaging using an annular-ring CMUT array
    Degertekin, FL
    Karaman, M
    Guldiken, RO
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 129 - 132
  • [4] A Study of an Annular Array CMUT Device for the making of Forward Looking IVUS
    Lee, Seungmok
    Ikeda, Junji
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [5] Forward-looking IVUS imaging using a dual-annular ring CMUT array: Experimental results
    Guldiken, R.
    Zahorian, J.
    Gurun, G.
    Qureshi, M. S.
    Balantekin, M.
    Tekes, C.
    Hasler, P.
    Karaman, M.
    Carlier, S.
    Degertekin, F. L.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1247 - +
  • [6] Experimental Study of Dual-Ring CMUT Array Optimization for Forward-Looking IVUS
    Tekes, Coskun
    Zahorian, Jaime
    Gurun, Gokce
    Satir, Sarp
    Hochman, Michael
    Xu, Toby
    Rashid, M. Wasequr
    Degertekin, F. Levent
    Karaman, Mustafa
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1127 - 1130
  • [7] Real-Time Coded Excitation Imaging Using a CMUT-Based Side Looking Array for Intravascular Ultrasound
    Zangabad, Reza Pakdaman
    Bosch, Johan G.
    Mastik, Frits
    Beurskens, Robert H. S. H.
    Henneken, Vincent A.
    Weekamp, Johannes W.
    van der Steen, Antonius F. W.
    van Soest, Gijs
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (06) : 2048 - 2058
  • [8] Volumetric Imaging Using Single Chip Integrated CMUT-on-CMOS IVUS Array
    Tekes, Coskun
    Zahorian, Jaime
    Gurun, Gokce
    Satir, Sarp
    Xu, Toby
    Hochman, Michael
    Degertekin, F. Levent
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3195 - 3198
  • [9] Design of ultrasonic array transducer for downhole forward-looking imaging
    Meng, Weidong
    Yan, Shouguo
    Huang, Juan
    Zhang, Bixing
    Shengxue Xuebao/Acta Acustica, 2025, 50 (01): : 138 - 148
  • [10] Annular-ring CMUT arrays for forward-looking IVUS: Transducer characterization and imaging
    Degertekin, FL
    Guldiken, RO
    Karaman, M
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (02) : 474 - 482