Pathologic Comparison of Asymmetric or Sulcus Fixation of 3-Piece Intraocular Lenses with Square Versus Round Anterior Optic Edges

被引:11
|
作者
Ollerton, Andrew [1 ]
Werner, Liliana [1 ]
Strenk, Susan [2 ]
Strenk, Lawrence [2 ]
Leishman, Lisa [1 ]
Bodnar, Zachary [1 ]
Kirk, Kevin R. [1 ]
Michelson, Jennifer [1 ,3 ]
Mamalis, Nick [1 ]
机构
[1] Univ Utah, John A Moran Eye Ctr, Salt Lake City, UT 84132 USA
[2] MRI Res Inc, Cleveland, OH USA
[3] Tufts Med Sch, Boston, MA USA
关键词
PIGMENTARY DISPERSION SYNDROME; POSTERIOR CAPSULE RUPTURE; HUMAN CADAVER EYES; IOL IMPLANTATION; BAG OPACIFICATION; SECONDARY; PRESSURE; COMPLICATIONS; DECENTRATION; PLACEMENT;
D O I
10.1016/j.ophtha.2013.01.029
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate the pathologic findings of 3-piece intraocular lenses (IOLs) with asymmetric or sulcus fixation in pseudophakic cadaver eyes, comparing IOLs with square or round edges on the anterior optic surface. Design: Comparative case series with pathology. Participants: A total of 661 pseudophakic cadaver eyes, obtained from eye banks within the United States, implanted with different IOLs. Methods: Anterior segment scanning of whole eyes with a high-frequency ultrasound system or high-resolution anterior segment magnetic resonance imaging followed by gross examination. Selected eyes were processed for complete histopathologic analysis. Main Outcome Measures: Findings from imaging, gross, and histopathologic evaluation that could be related to out-of-the-bag fixation of the lenses. Results: Of 661 pseudophakic cadaver eyes obtained, 13 had 3-piece hydrophobic acrylic IOLs with anterior and posterior square optic edges, and 14 had 3-piece lenses with anterior round edges (13 silicone lenses and 1 hydrophobic acrylic lens) without symmetric in-the-bag fixation. These 27 selected eyes were processed for complete histopathologic analysis. Gross findings in both groups were composed of IOL decentration and tilt, pigmentary dispersion within the anterior segment and on the IOL surface, and iris transillumination defects. Histopathology of the 14 eyes with 3-piece IOLs with round anterior optic edges showed mild focal disruption of the iris pigmented layer and loop protrusion/erosion in the ciliary sulcus. Additional changes observed in the 13 eyes with square anterior optic edge IOLs included iris changes, such as vacuolization, disruption and loss of the pigmented epithelial layers, iris thinning and atrophy, synechiae, and pigmentary dispersion within the trabecular meshwork. One eye also exhibited initial signs of optic nerve disc cupping. Conclusions: In this series, pathologic findings were more severe in eyes implanted with 3-piece IOLs with square anterior optic edges, suggesting that IOLs with round anterior edges are more suitable for sulcus fixation. (c) 2013 by the American Academy of Ophthalmology.
引用
收藏
页码:1580 / 1587
页数:8
相关论文
共 20 条
  • [1] Sulcus Fixation of a 3-Piece Diffractive Multifocal Intraocular Lens with and without Optic Capture in the Anterior Capsulorhexis
    Chang, John S. M.
    Ng, Jack C. M.
    Chan, Vincent K. C.
    OPHTHALMOLOGY, 2014, 121 (01) : 429 - 430
  • [2] Pathologic Assessment of Complications with Asymmetric or Sulcus Fixation of Square-Edged Hydrophobic Acrylic Intraocular Lenses
    Kirk, Kevin R.
    Werner, Liliana
    Jaber, Ryan
    Strenk, Susan
    Strenk, Lawrence
    Mamalis, Nick
    OPHTHALMOLOGY, 2012, 119 (05) : 907 - 913
  • [3] Anterior segment parameters: Comparison of 1-piece and 3-piece acrylic foldable intraocular lenses
    Behrouz, Mahmoud Jabbarvand
    Kheirkhah, Ahmad
    Hashemian, Hesam
    Nazari, Rahman
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10): : 1650 - 1655
  • [4] Decentration of 3-piece versus plate-haptic silicone intraocular lenses
    Hwang, IP
    Clinch, TE
    Moshifar, M
    Malmquist, L
    Cason, M
    Crandall, AS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (11): : 1505 - 1508
  • [5] Transconjunctival sutureless intrascleral fixation of 3-piece intraocular lenses using a curved needle
    Genc, Selim
    Cakir, Hanefi
    Baykara, Mehmet
    Esen, Fehim
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (08): : 969 - 970
  • [6] Influence of Sutureless Scleral Fixation Techniques With 3-Piece Intraocular Lenses on Dislocation Force
    Zeilinger, Johannes
    Kronschlaeger, Martin
    Schlatter, Andreas
    Ruiss, Manuel
    Bayer, Natascha
    Findl, Oliver
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 264 : 229 - 234
  • [7] Incision sizes with 5.5 mm total optic, 3-piece foldable intraocular lenses
    Kohnen, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (12): : 1765 - 1772
  • [8] Comparison of tilt and decentration of 1-piece and 3-piece hydrophobic acrylic intraocular lenses
    Mutlu, FM
    Erdurman, C
    Sobaci, G
    Bayraktar, MZ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (02): : 343 - 347
  • [9] Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule
    Hayashi, K
    Hayashi, H
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (02): : 337 - 342
  • [10] Refractive outcome of trocar-assisted sutureless scleral fixation with 3-piece intraocular lenses
    Veysel Aykut
    Fehim Esen
    Fatma Sali
    Halit Oguz