Deiodination of iodinated aromatic compounds with electrospray ionization mass spectrometry

被引:4
|
作者
Hvattum, Erlend [1 ]
Priebe, Hanno [2 ]
机构
[1] GE Healthcare, Med Diagnost R&D, N-0401 Oslo, Norway
[2] Univ Oslo, Sch Pharm, Dept Pharmaceut Chem, N-0316 Oslo, Norway
关键词
RAY CONTRAST-MEDIA; BEAM-INDUCED DEHALOGENATION; DEGRADATION; ENVIRONMENT; IODIXANOL; AM1;
D O I
10.1002/rcm.6711
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALEDehalogenation of iodinated X-ray contrast media (ICM) has been reported using electrochemical and bioelectrochemical systems. Correspondingly, dehalogenation of aromatic halogens has also been reported in mass spectrometry (MS) using different ionization techniques like chemical ionization (CI), thermospray, fast-atom bombardment (FAB) and FAB-liquid secondary ionization mass spectrometry (LSIMS). The aim of the present work was to study deiodination of iodinated aromatic compounds in MS with electrospray ionization (ESI). METHODSThe iodinated aromatic compounds were characterized by liquid chromatography/tandem mass spectrometry (LC/MS/MS) using a quadrupole time-of-flight (QTof)-micro MS instrument and ESI in both positive and negative ion mode. The effect of mobile phase additives like formic acid, acetic acid, trifluoroacetic acid, ammonium formate and ammonium acetate on the negative and positive ESI mass spectra of the iodinated aromatic compounds was studied. RESULTSFormic acid and ammonium formate induced deiodination of the iodinated aromatic compounds with ESI-MS. Neither acetic acid, trifluoroacetic acid nor ammonium acetate induced the deiodination reaction. The effect was most pronounced with negative ESI where the HI product of the deiodination reaction easily adhered to the aromatic compounds giving rise to HI adducts in the mass spectra. The deiodination reaction was shown to take place in the ESI capillary, since the extent of the reaction was largely dependent on the capillary voltage. The calculated heat of reaction for deiodination of the iodinated aromatic compounds was significantly exothermic for formic acid. This was not the case for acetic acid and trifluoroacetic acid. CONCLUSIONSCare should be taken when using formic acid as a mobile phase additive in LC/MS analyses of iodinated aromatic compounds, since the interpretation of the mass spectra might be influenced by potential dehalogenation reactions taking place in the ESI capillary. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:2504 / 2514
页数:11
相关论文
共 50 条
  • [1] Electrospray ionization mass spectrometry of organogermanium compounds
    Wei, JH
    Chen, J
    Miller, JM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (03) : 169 - 181
  • [3] Electrospray positive ionization tandem mass spectrometry of Amadori compounds
    Wang, Jun
    Lu, Yi-Min
    Liu, Bai-Zhan
    He, He-Yong
    JOURNAL OF MASS SPECTROMETRY, 2008, 43 (02): : 262 - 264
  • [4] Study of electrospray ionization tandem mass spectrometry of the benzofuranone compounds
    Zhan Qi Niu
    Yu Min Sun
    Feng Niu
    Jian Han
    Da Wei Chen
    CHINESE CHEMICAL LETTERS, 2008, 19 (03) : 324 - 328
  • [5] Nanoaggregation of Polyaromatic Compounds Probed by Electrospray Ionization Mass Spectrometry
    Liu, Lan
    Sjoblom, Johan
    Xu, Zhenghe
    ENERGY & FUELS, 2016, 30 (05) : 3742 - 3751
  • [6] Electrospray ionization mass spectrometry
    Banks, JF
    Whitehouse, CM
    HIGH RESOLUTION SEPARATION AND ANALYSIS OF BIOLOGICAL MACROMOLECULES, PT A, 1996, 270 : 486 - 519
  • [7] Electrospray Ionization for Mass Spectrometry
    不详
    LC GC NORTH AMERICA, 2012, 30 (02) : 182 - 182
  • [8] Towards the electrospray ionization mass spectrometry ionization efficiency scale of organic compounds
    Leito, Ivo
    Herodes, Koit
    Huopolainen, Merit
    Virro, Kristina
    Kunnapas, Allan
    Kruve, Anneli
    Tanner, Risto
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (03) : 379 - 384
  • [9] Electrospray ionization mass spectrometry and tandem mass spectrometry of clodronate and related bisphosphonate and phosphonate compounds
    Huikko, K
    Kotiaho, T
    Yli-Kauhaluoma, J
    Kostiainen, R
    JOURNAL OF MASS SPECTROMETRY, 2002, 37 (02): : 197 - 208
  • [10] Study of cyclization of chelating compounds using electrospray ionization mass spectrometry
    Shi, Y
    Campbell, JA
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 245 (02) : 293 - 300