Hall-array gradiometer for measurement of the magnetic induction vector in superconductors

被引:5
|
作者
Abulafia, Y
Wolfus, Y
McElfresh, M
Shaulov, A
Yeshurun, Y
Paltiel, Y
Shtrikman, H
Zeldov, E
机构
[1] Weizmann Inst Sci, Dept Condensed Matter Phys, IL-76100 Rehovot, Israel
[2] Purdue Univ, Dept Phys, W Lafayette, IN 47907 USA
[3] Bar Ilan Univ, Dept Phys, Inst Superconduct, Ramat Gan, Israel
关键词
D O I
10.1063/1.369865
中图分类号
O59 [应用物理学];
学科分类号
摘要
An experimental technique for measuring the distribution of the normal and planar components of the magnetic induction near the surface of a superconducting sample is described. This technique utilizes a design of a double-layered Hall sensor array fabricated from a GaAs/AlGaAs heterostructure containing two parallel layers of a two-dimensional electron gas. Applications of this technique are demonstrated in measuring the current density distribution and in characterizing the flux creep process in a thin YBa2Cu3O7 crystal. (C) 1999 American Institute of Physics. [S0021-8979(99)31408-0].
引用
收藏
页码:5471 / 5473
页数:3
相关论文
共 50 条
  • [1] Measurement of the magnetic induction vector in superconductors using a double-layer Hall sensor array
    Abulafia, Y
    McElfresh, M
    Shaulov, A
    Yeshurun, Y
    Paltiel, Y
    Majer, D
    Shtrikman, H
    Zeldov, E
    APPLIED PHYSICS LETTERS, 1998, 72 (22) : 2891 - 2893
  • [2] Magnetic Induction Sensing with a Gradiometer Coil and Measurement Circuit
    Xiang, Jinxi
    Xiong, Hao
    Dong, Yonggui
    2018 IEEE SENSORS, 2018, : 370 - 372
  • [3] Hall-array measurements of flux creep parameters in Y-Ba-Cu-O crystals
    Abulafia, Y
    Shaulov, A
    Wolfus, Y
    Prozorov, R
    Burlachkov, L
    Majer, D
    Zeldov, E
    Vinokur, VM
    Yeshurun, Y
    JOURNAL OF LOW TEMPERATURE PHYSICS, 1997, 107 (5-6) : 455 - 465
  • [4] Hall-array measurements of flux creep parameters in Y-Ba-Cu-O crystals
    Y. Abulafia
    A. Shaulov
    Y. Wolfus
    R. Prozorov
    L. Burlachkov
    D. Majer
    E. Zeldov
    V.M. Vinokur
    Y. Yeshurun
    Journal of Low Temperature Physics, 1997, 107 : 455 - 465
  • [5] Measurement of liver iron overload by magnetic induction using a planar gradiometer:: preliminary human results
    Casañas, R
    Scharfetter, H
    Altes, A
    Remacha, A
    Sarda, P
    Sierra, J
    Merwa, R
    Hollaus, K
    Rosell, J
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) : 315 - 323
  • [6] Design and Development of Distributed Magnetic Measurement System Based on Hall Array
    Deng, Ce
    Zhang, Ming
    INTERNATIONAL CONFERENCE ON SENSORS AND INSTRUMENTS (ICSI 2021), 2021, 11887
  • [7] High-precision Hall Sensor Array Magnetic Field Measurement System
    Zhang, Jidong
    Zhu, Ya
    Qian, Maofei
    Zhang, Wei
    13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2018), 2019, 2054
  • [8] A new type of gradiometer for the receiving circuit of magnetic induction tomography
    Scharfetter, H
    Merwa, R
    Pilz, K
    PHYSIOLOGICAL MEASUREMENT, 2005, 26 (02) : S307 - S318
  • [9] New magnetosensitive component for measurement of magnetic-induction vector parameters
    A. I. Galushkov
    I. M. Romanov
    Yu. A. Chaplygin
    Measurement Techniques, 1998, 41 : 22 - 26
  • [10] New magnetosensitive component for measurement of magnetic-induction vector parameters
    Galushkov, AI