Influence of cement stiffness and bone morphology on the compressive properties of bone-cement composites in simulated vertebroplasty

被引:10
|
作者
Helgason, B. [1 ,2 ]
Stirnimann, P. [1 ]
Widmer, R. [1 ,2 ]
Boger, A. [3 ,4 ]
Ferguson, S. J. [1 ,2 ]
机构
[1] Univ Bern, Inst Surg Technol & Biomech, CH-3012 Bern, Switzerland
[2] ETH, Inst Biomech, Zurich, Switzerland
[3] Synthes GmbH, R&D Biomat, Oberdorf, Switzerland
[4] Ansbach Univ Appl Sci, Ansbach, Germany
关键词
bone-cement; bone; composite; finite element analysis; mechanical properties; FINITE-ELEMENT MODELS; MECHANICAL-PROPERTIES; IN-VITRO; TRABECULAR BONE; VERTEBRAL BODY; PMMA; KYPHOPLASTY; DENSITY; VOLUME;
D O I
10.1002/jbm.b.32847
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Vertebroplasty is widely used to treat vertebral compression fractures. Little is known about the influence of morphological parameters of the bone on the properties of the bonecement composite. Furthermore, although generic finite element (FE) models have been suggested as a way to compute the values of these properties, their accuracy has not been established. In the experimental part of this study, we tested bovine cancellous bone and three different polymethylmethacrylate bone cements and determined six quasi-static uniaxial compressive properties of bonecement composite specimens and 10 morphological parameters of the bone. For the FE work, we used two simulations, one being mu FE and the other unit cell FE. In conclusion, we found that (1) for composite specimens, that relative contribution of the cement to the overall response of the composite increases with increasing cement stiffness; (2) the anisotropy ratio is the bone morphological property that exerts the most significant influence on the experimentally obtained compressive properties of the bonecement composites determined; (3) the accuracy of the computed compressive properties of the composites ranged from low to high, depending on simulation method used. The largest errors, however, can partially be explained by difference in boundary conditions between the experimental testing and the simulation techniques. The lattermost finding points to the potential for simplified FE models being incorporated into automatic material mapping schemes in whole bone vertebra FE simulations. (c) 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2013.
引用
收藏
页码:364 / 374
页数:11
相关论文
共 50 条
  • [1] THE PROPERTIES OF PMMA BONE-CEMENT
    LEE, AJC
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1983, 19 (12): : 1116 - 1116
  • [2] THE DIFFUSION PROPERTIES OF BONE-CEMENT
    GILMORE, MFX
    FLEMING, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1982, 64 (03): : 382 - 383
  • [3] BONE-CEMENT
    SLADE, JM
    ANAESTHESIA, 1989, 44 (02) : 180 - 180
  • [4] THE EFFECT OF POLYMETHYLMETHACRYLATE BONE-CEMENT VIBRATION ON THE BONE-CEMENT INTERFACE
    THOMAS, AMC
    MCMINN, DJW
    HADDAWAY, M
    MCCALL, IW
    CELLS AND MATERIALS, 1992, 2 (02): : 163 - 168
  • [5] INFLUENCE OF MIXING CONDITIONS ON PMMA BONE-CEMENT PROPERTIES
    EYERER, P
    JIN, R
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1986, 124 (04): : 527 - 529
  • [6] Compressive fatigue properties of a commercially available acrylic bone cement for vertebroplasty
    Ingrid Ajaxon
    Cecilia Persson
    Biomechanics and Modeling in Mechanobiology, 2014, 13 : 1199 - 1207
  • [7] Compressive fatigue properties of a commercially available acrylic bone cement for vertebroplasty
    Ajaxon, Ingrid
    Persson, Cecilia
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2014, 13 (06) : 1199 - 1207
  • [8] RADIOACTIVITY OF BONE-CEMENT
    SCHERER, MA
    WINKLER, R
    ASCHERL, R
    LENZ, E
    RADIOLOGE, 1993, 33 (01): : 46 - 50
  • [9] MECHANICAL CHARACTERISTICS OF HUMAN BONE-CEMENT COMPOSITES
    JOFE, MH
    SCHEIN, SS
    WHITE, AA
    HAYES, WC
    JOURNAL OF BIOMECHANICS, 1982, 15 (04) : 343 - 344
  • [10] BONE-CEMENT IN ORTHOPEDICS
    RUSHTON, N
    EQUINE VETERINARY JOURNAL, 1984, 16 (06) : 486 - 487