Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography

被引:351
|
作者
Geleijnse, ML
Fioretti, PM
Roelandt, JRTC
机构
[1] Thoraxcentre, Univ. Hosp. Rotterdam-Dijkzigt E., Rotterdam
关键词
D O I
10.1016/S0735-1097(97)00206-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Large numbers of patients referred for evaluation of chest pain are unable to perform adequate, diagnostic exercise testing. In these patients, dobutamine stress echocardiography (DSE) represents an alternative, exercise-independent stress modality. Apart from the similar to 5% of patients with an inadequate acoustic window, 10% of patients referred for this test have nondiagnostic (sub-maximal negative) test results. Serious side effects during or shortly after DSE are uncommon, with ventricular fibrillation or myocardial infarction occurring in similar to 1 of 2,000 studies. No deaths have been reported. On the basis of a total number of 2,246 patients, reported in 28 studies, the sensitivity, specificity and accuracy of the test for the detection of coronary artery disease (CAD) were 80%, 84% and 81%, respectively. Mean sensitivities for one-, two- and three-vessel disease were 74%, 86% and 92%, respectively. The sensitivity for detection of disease in the left circumflex coronary artery (55%) was lower, both compared with that for left anterior descending (72%) and right coronary artery disease (76%). The sensitivity of predicting multivessel disease by multiregion echocardiographic abnormalities varied widely, from 8% to 71%. In direct comparisons, DSE was superior to exercise electrocardiography and dipyridamole echocardiography and comparable to exercise echocardiography and radionuclide imaging,DSE is a useful, feasible and safe exercise-independent stress modality for assessing the presence, localization and extent of CAD. (C) 1997 by the American College of Cardiology.
引用
收藏
页码:595 / 606
页数:12
相关论文
共 50 条
  • [1] Harmonic dobutamine stress echocardiography: Does contrast make a difference in diagnostic feasibility and accuracy?
    Mulvagh, SL
    Rainbird, AJ
    Al-Mansour, HA
    Klarich, KW
    Foley, DA
    Kuvelas, T
    Miller, JJ
    CIRCULATION, 1998, 98 (17) : 356 - 356
  • [2] Factors influencing the diagnostic accuracy of dobutamine stress echocardiography
    K. Schröder
    R. Agrawal
    H. Völler
    B. Kürsten
    R. Dissmann
    H.-P. Schultheiss
    The International Journal of Cardiac Imaging, 1997, 13 : 493 - 498
  • [3] Factors influencing the diagnostic accuracy of dobutamine stress echocardiography
    Schroder, K
    Agrawal, R
    Voller, H
    Kursten, B
    Dissmann, R
    Schultheiss, HP
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1997, 13 (06): : 493 - 498
  • [4] Feasibility, safety and tolerability of accelerated dobutamine stress echocardiography
    Minardi G.
    Manzara C.
    Pulignano G.
    Pino P.G.
    Pavaci H.
    Sordi M.
    Cardiovascular Ultrasound, 5 (1)
  • [5] A third generation dobutamine-atropine stress echocardiography protocol: Feasibility, accuracy, and safety.
    Schroder, K
    Beckmann, S
    Dingerkus, H
    Krahwinkel, W
    Nixdorff, U
    Voller, H
    Kursten, B
    CIRCULATION, 1996, 94 (08) : 3972 - 3972
  • [6] SAFETY AND FEASIBILITY OF ACCELERATED DOBUTAMINE-ATROPINE STRESS ECHOCARDIOGRAPHY
    Tang, J.
    Gin, K.
    Lee, P. K.
    Nair, P.
    Tsang, T.
    Jue, J.
    CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S251 - S251
  • [7] Feasibility and safety of dobutamine stress echocardiography: Experience in 1000 patients
    Zahn, R
    Lotter, R
    Nohl, H
    Schiele, R
    Bergmeier, C
    Zander, M
    Seidl, K
    Senges, J
    ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 (01): : 28 - 34
  • [8] Safety and feasibility of dobutamine and dipyridamole stress echocardiography in hypertensive patients
    Cortigiani, L
    Zanetti, L
    Bigi, R
    Desideri, A
    Fiorentini, C
    Nannini, E
    JOURNAL OF HYPERTENSION, 2002, 20 (07) : 1423 - 1429
  • [9] Safety and diagnostic value of dobutamine stress echocardiography in patients with hypertension
    Nemchyna, OO
    Lutay, MI
    Tsyzh, OV
    Golikova, IP
    JOURNAL OF HYPERTENSION, 2005, 23 : S165 - S166
  • [10] Safety, feasibility, and diagnostic accuracy of accelerated high-dose dipyridamole stress echocardiography
    Dal Porto, R
    Faletra, F
    Picano, E
    Pirelli, S
    Moreo, A
    Varga, A
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (05): : 520 - 524