Installation Angle Offset Compensation of Puncture Robot Based on Measurement of Needle by CT Equipment

被引:0
|
作者
Nagao, Akisato [1 ]
Matsuno, Takayuki [1 ]
Kimura, Kazusi [1 ]
Kamegawa, Tetsushi [1 ]
Minami, Mamoru [1 ]
Hiraki, Takao [2 ]
机构
[1] Okayama Univ, Grad Sch Nat Sci & Technol, Kita Ku, 1-1-1 Tsushimanaka, Okayama, Okayama 7008530, Japan
[2] Okayama Univ Hosp, Dept Radiol, Kita Ku, 2-5-1 Shikata, Okayama, Okayama 7008558, Japan
关键词
Surgery Support Robot; Interventional Radiology; Puncture Robot;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A medical procedure called Interventional Radiology(IR) is paid much attention in recent years. IR can be performed percutaneously while a doctor observes patient' s fluoroscopic image. Therefore this surgical method is low-invasiveness method. In this surgery, computed tomography (CT) equipment is often used. But a doctor is exposed to strong radiation from CT. Thus, we have developed a remote-controlled surgery support robot called "Zerobot". Because Zerobot is placed front of CT equipment by human, an angle offset from installation target position occurs. If a doctor punctures without noticing that Zerobot has an installation angle offset, there is danger of hurting the part that should not be hurt around a target cancer. In order to solve this problem, we propose an angle offset compensation method and the installation angle offset derivation method using a CT equipment is proposed. Then, effectiveness of proposed method is confirmed through experiments.
引用
收藏
页码:451 / 457
页数:7
相关论文
共 50 条
  • [1] The measurement of small angle offset based on tangent displacement
    Department of Optical Engineering, Beijing Institute of Technology, Beijing 100081, China
    不详
    Guangxue Jishu, 2007, 3 (462-463+467):
  • [2] Offset Compensation for Differential Charge-Based Capacitance Measurement
    Cascone, N.
    Ferlito, U.
    Bruno, G.
    Cassalini, Mirko
    Grasso, Alfio Dario
    2024 19TH CONFERENCE ON PH.D RESEARCH IN MICROELECTRONICS AND ELECTRONICS, PRIME 2024, 2024,
  • [3] Offset compensation for differential charge-based capacitance measurement
    Cascone, Nicolo
    Cassalini, Mirko
    Ferlito, Umberto
    Grasso, Alfio Dario
    Bruno, Giuseppe
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2024, 52 (12) : 5961 - 5971
  • [4] Registration and motion compensation CT-guided spinal of a needle placement robot for procedures
    Xu, S
    Cleary, K
    Stoianovici, D
    Fichtinger, G
    MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 : 661 - 669
  • [5] Robot-Assisted Needle Insertion for CT-Guided Puncture: Experimental Study with a Phantom and Animals
    Chen, Xiangqian
    Yan, Yadong
    Li, Ailing
    Wang, Tianmiao
    Wang, Yu
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 46 (01) : 128 - 135
  • [6] Robot-Assisted Needle Insertion for CT-Guided Puncture: Experimental Study with a Phantom and Animals
    Xiangqian Chen
    Yadong Yan
    Ailing Li
    Tianmiao Wang
    Yu Wang
    CardioVascular and Interventional Radiology, 2023, 46 : 128 - 135
  • [7] Measurement Based Throughput Evaluation of Residual Frequency Offset Compensation in WiMAX
    Wang, Qi
    Caban, Sebastian
    Mehlfuhrer, Christian
    Rupp, Markus
    PROCEEDINGS ELMAR-2009, 2009, : 233 - 236
  • [8] Ultra-High Resistance Measurement Based On Offset Current Compensation
    Wang, Xiaojun
    Zhao, Yongjie
    Xue, Jian
    MECHATRONICS, ROBOTICS AND AUTOMATION, PTS 1-3, 2013, 373-375 : 856 - +
  • [9] Misalignment angle measurement and angle measurement deviation compensation of fiber optic gyroscope based on tilt sensor
    Mou, Jiapeng
    Su, Jingjing
    Miao, Lijun
    Huang, Tengchao
    OPTICAL FIBER TECHNOLOGY, 2021, 63
  • [10] Roll angle measurement based on common path compensation principle
    Zhu, Yiwei
    Liu, Shaocong
    Kuang, Cuifang
    Li, Shuai
    Liu, Xu
    OPTICS AND LASERS IN ENGINEERING, 2015, 67 : 66 - 73