Shake table testing of unbonded post-tensioned concrete walls with and without additional energy dissipation

被引:44
|
作者
Twigden, K. M. [1 ]
Henry, R. S. [2 ]
机构
[1] Aurecon, POB 9762, Auckland 1149, New Zealand
[2] Univ Auckland, Dept Civil & Environm Engn, Private Bag 92019, Auckland 1142, New Zealand
关键词
Unbonded post-tensioning; Precast concrete; Shear walls; Shake table testing; PreWEC; O-connector; SEISMIC PERFORMANCE; PRECAST; BEHAVIOR; ROCKING; SYSTEMS; DESIGN; PREWEC; STRAIN;
D O I
10.1016/j.soildyn.2018.05.007
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Recently an innovative unbonded Post-Tensioned (PT) concrete wall system was developed that consists of a Precast Wall with End Columns (PreWEC). Dynamic testing was conducted to better understand the seismic response of PreWEC systems and to provide further dynamic test results of PT rocking wall systems. Three unbonded PT concrete walls, including one SRW and two PreWEC systems that incorporated O-connector dissipaters were subjected to a suite of seven spectrum compatible ground motions at different intensity levels in addition to three recent ground motions at natural scale. Negligible damage to the concrete wall panels was observed for all three systems throughout the entire sequence of testing. As expected both PreWEC systems demonstrated higher energy dissipation and lateral-load capacity in comparison to the SRW due to the addition of the O-connectors. This resulted in SRW-A experiencing higher average drifts and lower accelerations than the two PreWEC systems. An intensity measure referred to as an 'Achieved return period factor' was defined based on comparing the measured table acceleration response spectrum to a target code response spectrum. The increased spread of both peak acceleration and peak drift versus the achieved return period factor for SRW-A in comparison to both PreWEC systems highlights the more sensitive and unpredictable nature of the SRW as a result of limited damping. The measured inherent damping from the white noise tests was found to range between 3.5% and 4.0% for the three walls. Negligible residual drifts were measured for all walls despite higher static residual drifts being estimated from previously performed cyclic testing on identical walls.
引用
收藏
页码:375 / 389
页数:15
相关论文
共 50 条
  • [1] Shaking table investigation of unbonded post-tensioned concrete rocking walls
    Wang, Jiawei
    Zhou, Wei
    Ahmed, Ahmad Omar
    STRUCTURES, 2024, 63
  • [2] Defining Concrete Compressive Strain in Unbonded Post-Tensioned Walls
    Henry, Richard S.
    Brooke, Nicholas J.
    Sritharan, Sri
    Ingham, Jason M.
    ACI STRUCTURAL JOURNAL, 2012, 109 (01) : 101 - 111
  • [3] ATLSS researchers testing unbonded post-tensioned shear walls
    不详
    PCI JOURNAL, 2000, 45 (06): : 125 - 126
  • [4] Lateral load tests of unbonded post-tensioned precast concrete walls
    Perez, FJ
    Pessiki, S
    Sause, R
    Lu, LM
    LARGE-SCALE STRUCTURAL TESTING, 2003, 211 : 161 - 182
  • [5] Seismic behavior and design of unbonded post-tensioned precast concrete walls
    Kurama, Yahya
    Pessiki, Stephen
    Sause, Richard
    Lu, Le-Wu
    PCI Journal, 44 (03): : 72 - 89
  • [6] Force-displacement behavior of unbonded post-tensioned concrete walls
    Hassanli, Reza
    ElGawady, Mohamed A.
    Mills, Julie E.
    ENGINEERING STRUCTURES, 2016, 106 : 495 - 505
  • [7] Damage controlling performance of unbonded post-tensioned precast concrete walls
    Obara T.
    Watanabe H.
    Kuwabara T.
    Kono S.
    2018, Architectural Institute of Japan (83): : 879 - 889
  • [8] Lateral load behavior of unbonded post-tensioned precast concrete walls
    Perez, FJ
    Sause, R
    Pessiki, S
    Lu, LW
    ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 423 - 430
  • [9] Seismic behavior and design of unbonded post-tensioned precast concrete walls
    Kurama, Y
    Pessiki, S
    Sause, R
    Lu, LW
    PCI JOURNAL, 1999, 44 (03): : 72 - 89
  • [10] Cyclic testing of unbonded post-tensioned concrete wall systems with and without supplemental damping
    Twigden, K. M.
    Sritharan, S.
    Henry, R. S.
    ENGINEERING STRUCTURES, 2017, 140 : 406 - 420