In-Vitro Assessment of the Effects of Transcatheter Aortic Valve Leaflet Design on Neo-Sinus Geometry and Flow

被引:14
|
作者
Ncho, Beatrice [1 ]
Sadri, Vahid [2 ,3 ]
Ortner, Jillian [2 ,3 ]
Kollapaneni, Sai [2 ,3 ]
Yoganathan, Ajit [1 ,2 ,3 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biomol Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Wallace H Coulter Sch Biomed Engn, Technol Enterprise Pk,387 Technol Circle NW,Suite, Atlanta, GA 30313 USA
[3] Emory Univ, Technol Enterprise Pk,387 Technol Circle NW,Suite, Atlanta, GA 30313 USA
关键词
TAVR; Leaflet thrombosis; Neo-sinus; Leaflet length; Leaflet insertion height; Flow stasis; Leaflet kinematics; Particle image velocimetry; FLUID-MECHANICS; BLOOD STASIS; THROMBOSIS; HEMODYNAMICS; IMPLANTATION; PATIENT;
D O I
10.1007/s10439-020-02664-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transcatheter aortic valve (TAV) leaflet thrombosis is a clinical risk with potentially fatal consequences. Studies have identified neo-sinus flow stasis as a cause of leaflet thrombosis. Flow stasis is influenced by the TAV leaflets, which affect the local fluid dynamics in the aortic sinus and neo-sinus. This study evaluated the effects of TAV leaflet features on the neo-sinus flow as a measure of leaflet thrombosis risk. Five TAVs of varied leaflet length and insertion height were tested in a simulator. Hydrodynamics and leaflet kinematics through en-phase imaging were quantified. Velocity fields were assessed using high-speed particle image velocimetry. Regions of flow stasis and particle residence times (PRTs) were quantified. TAVs with shorter leaflet length exhibited larger orifice areas and lower transvalvular pressure gradients. Shorter leaflet length and increased leaflet insertion TAVs additionally exhibited lower neo-sinus PRTs (0.44 +/- 0.21 vs 2.83 +/- 0.48 cycles, p < 0.05) and higher neo-sinus peak velocities (0.15 +/- 0.009 vs 0.07 +/- 0.005 m/s, p < 0.05) than TAVs with longer leaflet length and lower leaflet insertion. The average neo-sinus volume positively correlated with PRT(r = 0.810, p < 0.001), and extent of flow stasis (r = 0.682, p < 0.05). These results suggest that a small neo-sinus volume may reduce flow stagnation and particle residence, potentially reducing the risk of leaflet thrombosis. We propose that leaflet design features might be proactively controlled in the design of future transcatheter aortic valves.
引用
收藏
页码:1046 / 1057
页数:12
相关论文
共 50 条
  • [1] In-Vitro Assessment of the Effects of Transcatheter Aortic Valve Leaflet Design on Neo-Sinus Geometry and Flow
    Beatrice Ncho
    Vahid Sadri
    Jillian Ortner
    Sai Kollapaneni
    Ajit Yoganathan
    Annals of Biomedical Engineering, 2021, 49 : 1046 - 1057
  • [2] Effect of Native Aortic Leaflet Geometry Modification on Transcatheter Aortic Valve Neo-sinus and Aortic Sinus Flow: An In-vitro Study
    Beatrice E. Ncho
    Keshav Kohli
    Vahid Sadri
    Ajit P. Yoganathan
    Cardiovascular Engineering and Technology, 2023, 14 : 182 - 193
  • [3] Effect of Native Aortic Leaflet Geometry Modification on Transcatheter Aortic Valve Neo-sinus and Aortic Sinus Flow: An In-vitro Study
    Ncho, Beatrice E.
    Kohli, Keshav
    Sadri, Vahid
    Yoganathan, Ajit P.
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2023, 14 (02) : 182 - 193
  • [4] Transcatheter aortic valve deployment influences neo-sinus thrombosis risk: An in vitro flow study
    Madukauwa-David, Immanuel David
    Sadri, Vahid
    Kamioka, Norihiko
    Midha, Prem A.
    Raghav, Vrishank
    Oshinski, John N.
    Sharma, Rahul
    Babaliaros, Vasilis
    Yoganathan, Ajit P.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (05) : 1009 - 1016
  • [5] The Effects of the LAMPOON Procedure on Flow in the Mitral Valve Anterior Leaflet Neo-Sinus
    Easley, Thomas F.
    Sadri, Vahid
    Dorbala, Pranav
    Kamioka, Norihiko
    Babaliaros, Vasilis
    Yoganathan, Ajit P.
    CIRCULATION, 2019, 140
  • [6] In-vitro analysis of neo-sinus flow dynamics after transcatheter aortic valve replacement using particle image velocimetry technique
    Xu X.
    Hattori K.
    Ai R.
    Iwasaki K.
    Journal of Biorheology, 2023, 37 (02) : 162 - 169
  • [7] NEO-SINUS FLOW STASIS CORRELATES WITH LEAFLET THROMBOSIS ACROSS MULTIPLE TRANSCATHETER AORTIC VALVES
    Sadri, Vahid
    Trusty, Phillip
    Bhat, Sanchita S.
    Salim, Md Tausif
    Kamioka, Norihiko
    Sharma, Rahul
    Makkar, Raj R.
    Yoganathan, Ajit
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1104 - 1104
  • [8] Impact of Basilica on Sinus and Neo-Sinus Washout After Transcatheter Aortic Valve-in-Valve
    Hatoum, Hoda
    Maureira, Pablo
    Lilly, Scott
    Dasi, Lakshmi Prasad
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (04) : S42 - S42
  • [9] Native Valve and Neo-Sinus Remodeling Following Transcatheter Aortic Valve Replacement
    Yoon, Joshua
    Gill, Hacina
    Jelisejevas, Julius
    Meier, David
    Lai, Althea
    Seidman, Michael
    Payne, Geoffrey
    Webb, John
    Sathananthan, Janarthanan
    Sellers, Stephanie
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B250 - B250
  • [10] Native Valve and Native Neo-Sinus Remodeling Following Transcatheter Aortic Valve Replacement
    Yoon, Joshua
    Gill, Hacina
    Jelisejevas, Julius
    Lai, Althea
    Khan, Jaffar M.
    Payne, Geoffrey W.
    Webb, John G.
    Sathananthan, Janarthanan
    Seidman, Michael A.
    Meier, David
    Sellers, Stephanie L.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (12)