Full-Field Thickness Distribution of Human Tympanic Membrane Obtained with Optical Coherence Tomography

被引:118
|
作者
Van der Jeught, Sam [1 ]
Dirckx, Joris J. J. [1 ]
Aerts, Johan R. M. [1 ]
Bradu, Adrian [2 ]
Podoleanu, Adrian Gh [2 ]
Buytaert, Jan A. N. [1 ]
机构
[1] Univ Antwerp, Lab Biomed Phys, B-2020 Antwerp, Belgium
[2] Univ Kent, Sch Phys Sci, Appl Opt Grp, Canterbury CT2 7NH, Kent, England
基金
欧洲研究理事会;
关键词
eardrum; OCT; finite element modeling; pars tensa; 3D model; HUMAN MIDDLE-EAR; FINITE-ELEMENT-METHOD; MODEL; FIXATION; SYSTEM; FORMALDEHYDE; MICROSCOPY; MORPHOLOGY; BEHAVIOR;
D O I
10.1007/s10162-013-0394-z
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The full-field thickness distribution, three-dimensional surface model and general morphological data of six human tympanic membranes are presented. Cross-sectional images were taken perpendicular through the membranes using a high-resolution optical coherence tomography setup. Five normal membranes and one membrane containing a pathological site are included in this study. The thickness varies strongly across each membrane, and a great deal of inter-specimen variability can be seen in the measurement results, though all membranes show similar features in their respective relative thickness distributions. Mean thickness values across the pars tensa ranged between 79 and 97 mu m; all membranes were thinnest in the central region between umbo and annular ring (50-70 mu m), and thickness increased steeply over a small distance to approximately 100-120 mu m when moving from the central region either towards the peripheral rim of the pars tensa or towards the manubrium. Furthermore, a local thickening was noticed in the antero-inferior quadrant of the membranes, and a strong linear correlation was observed between inferior-posterior length and mean thickness of the membrane. These features were combined into a single three-dimensional model to form an averaged representation of the human tympanic membrane. 3D reconstruction of the pathological tympanic membrane shows a structural atrophy with retraction pocket in the inferior portion of the pars tensa. The change of form at the pathological site of the membrane corresponds well with the decreased thickness values that can be measured there.
引用
收藏
页码:483 / 494
页数:12
相关论文
共 50 条
  • [1] Full-Field Thickness Distribution of Human Tympanic Membrane Obtained with Optical Coherence Tomography
    Sam Van der Jeught
    Joris J. J. Dirckx
    Johan R. M. Aerts
    Adrian Bradu
    Adrian Gh Podoleanu
    Jan A. N. Buytaert
    Journal of the Association for Research in Otolaryngology, 2013, 14 : 483 - 494
  • [2] Rabbit tympanic membrane thickness distribution obtained via optical coherence tomography
    Livens, Pieter
    Dirckx, Joris J. J.
    HEARING RESEARCH, 2023, 429
  • [3] Human trabeculum imaging with full-field optical coherence tomography
    Stephane, Bertin
    Zwillinger, Stephanie
    Paques, Michel
    Baudouin, Christophe
    Labbe, Antoine
    Borderie, Vincent M.
    Grieve, Kate
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [4] In vivo imaging through the entire thickness of human cornea by full-field optical coherence tomography
    Mazlin, Viacheslav
    Xiao, Peng
    Dalimier, Eugenie
    Grieve, Kate
    Irsch, Kristina
    Sahel, Jose
    Fink, Mathias
    Boccara, Claude
    OPHTHALMIC TECHNOLOGIES XXVIII, 2018, 10474
  • [5] Research on full-field optical coherence tomography
    School of Electronic Engineering and Optoelectronic Technology, Nanjing University of Science and Technology, Nanjing
    210094, China
    不详
    214041, China
    Tongxin Xuebao, 12 (121-127):
  • [6] Preliminary Human Tympanic Membrane Thickness Data from Optical Coherence Tomography
    Buytaert, J.
    Van der Jeught, S.
    Ars, B.
    Podoleanu, A.
    Dirckx, J.
    OPTICAL MEASUREMENT TECHNIQUES FOR STRUCTURES & SYSTEMS2 (OPTIMESS2012), 2013, : 75 - 84
  • [7] novel mosaicking algorithm for in vivo full-field thickness mapping of the human tympanic membrane using low coherence interferometry
    Pande, Paritosh
    Shelton, Ryan L.
    Monroy, Guillermo L.
    Nolan, Ryan M.
    Boppart, Stephen A.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS XII, 2016, 9689
  • [8] Spatial coherence effect on layer thickness determination in narrowband full-field optical coherence tomography
    Safrani, Avner
    Abdulhalim, Ibrahim
    APPLIED OPTICS, 2011, 50 (18) : 3021 - 3027
  • [9] Human graft cornea imaging with full-field optical coherence tomography
    Ghouali, Wajdene
    Grieve, Kate
    Sandali, Otman
    Basli, Elena
    Bullet, Julien
    Laroche, Laurent
    Borderie, Vincent
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [10] Full-field optical coherence tomography of human donor and diseased corneas
    Ghouali, W.
    Grieve, K.
    Bellefqih, S.
    Laroche, L.
    Paques, M.
    Borderie, V.