The axial stability of the femur after harvest of the medial femoral condyle corticocancellous flap: A biomechanical study of composite femur models

被引:38
|
作者
Katz, Ryan D. [1 ]
Parks, Brent G. [1 ]
Higgins, James P. [1 ]
机构
[1] Union Mem Hosp, Curtis Natl Hand Ctr, Baltimore, MD 21218 USA
关键词
VASCULARIZED BONE-GRAFT; SUPRACONDYLAR REGION; ALVEOLAR RIDGE; RECONSTRUCTION; NONUNION;
D O I
10.1002/micr.20986
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Free bone or periosteal flaps from the medial femoral condyle are being employed for treatment of recalcitrant nonunions. When harvested in a corticocancellous fashion, these flaps have the potential to compromise the stability of the femur. This study is designed to test the axial stability of the femur after harvest of corticocancellous flaps using a standardized composite femur model. Methods: Corticocancellous defects of standardized width and depth ( 2 cm 3 1 cm) were designed with increasing length ( 3- cm intervals extending from 3 to 24 cm) over the medial femoral condyle of five composite femur models. After harvest of each corticocancellous block, the femur was subjected to an axial force of 9100 N loaded and unloaded over one second using a Mini- Bionix load frame. During the application of force, load and deformation data were collected from the load cell and linear variable differential transducer. To determine changes in stiffness or deformation with increasing flap sizes, analysis of variance with repeated measures was used. If the main effect was found to be significant, a Tukey's test was used to determine differences between specific flap sizes. Results: There were no femur fractures in any femurs for any flap size. Deformation during load increased as the size of the flap increased ( 2.19 mm 6 0.062 mm for the 3- cm flap defect) to ( 2.33 mm 6 0.113 mm for the 24- cm flap defect). Post- hoc testing of deformation shows a statistically significant difference only between the 3- cm flap defect and the 15- cm flap defect ( 2.19 vs. 2.30 mm) ( P 5 0.002). The range of stiffness is between 4,339 and 4,697 N mm 21. Stiffness tends to decrease significantly ( P < 0.001) with increasing flap size. Harvest of flap sizes greater or equal than 9 cm results in significantly lower stiffness compared to the 3- cm flap. Conclusions: In this composite femur model, when stressed with supraphysiologic forces, the femur retains its axial stability even after harvest of large corticocancellous flaps from its medial aspect. Statistical significance detected in deformation and stiffness may not be clinically relevant if the femur does not fracture after flap harvest. Such was the case in this experiment. The possibility exists of safely harvesting large flaps from this donor site. Corticocancellous flaps from the medial aspect of the femur may serve as an alternative to standard flaps used in medium and large osseous reconstructions. The size of flap that can be safely raised without compromising the stability of the femur has not yet been delineated. VVC 2012 Wiley Periodicals, Inc. Microsurgery 32: 213- 218, 2012.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 12 条
  • [1] Torsional Stability of the Femur after Harvest of the Medial Femoral Condyle Corticocancellous Flap
    Endara, Matthew R.
    Brown, Benjamin J.
    Shuck, John
    Bachabi, Malick
    Parks, Brent G.
    Higgins, James P.
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2015, 31 (05) : 364 - 368
  • [2] Iatrogenic Femur Fracture Following Medial Femoral Condyle Flap Harvest
    Haines, Morgan
    Baba, Mohammed
    Stewart, David A.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2020, 45 (09): : 885.e1 - 885.e3
  • [3] Femur Fracture Following Medial Femoral Condyle Flap Harvest: A Case Report
    Klarendic, Ana
    Dovsak, Tadej
    OPEN ACCESS SURGERY, 2021, 14 : 73 - 79
  • [4] Treatment of recalcitrant femur nonunion with pedicled corticoperiosteal medial femoral condyle flap
    Özdemir A.
    Odabaşı E.
    Eravsar E.
    Safalı S.
    Acar M.A.
    Scientific Reports, 13 (1)
  • [5] Iatrogenic femur fracture following medial femoral condyle flap harvest eventually requiring total knee arthroplasty in one patient
    Son, Ji H.
    Giladi, Aviram M.
    Higgins, James P.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2019, 44 (03) : 320 - 321
  • [6] Objective assessment of the effect of surgery on limb function after medial femoral condyle free flap harvest: biomechanical parameters
    Murawa, M.
    Szydlowski, J.
    Andruszko, A.
    Grabarek, B. O.
    Sirek, T.
    Fryzowicz, A.
    Kabacinski, J.
    Bernet, A.
    Banaszewski, J.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2025, 54 (02) : 123 - 129
  • [7] Cement penetration and primary stability of the femoral component after impaction allografting - A biomechanical study in the cadaveric femur
    Albert, C.
    Patil, S.
    Frei, H.
    Masri, B.
    Duncan, C.
    Oxland, T.
    Fernlund, G.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (07): : 962 - 970
  • [8] Supplemental medial small fragment fixation adds stability to distal femur fixation: A biomechanical study
    Goodnough, L. Henry
    Salazar, Brett P.
    Chen, Michael J.
    Storaci, Hunter
    Guzman, Robert
    Heffner, Michael
    Tam, Kaysie
    DeBaun, Malcolm R.
    Gardner, Michael J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (07): : 1670 - 1672
  • [9] Does Screw Location Affect the Risk of Subtrochanteric Femur Fracture After Femoral Neck Fixation? A Biomechanical Study
    Crump, Erica K.
    Quacinella, Michael
    Deafenbaugh, Bradley K.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2020, 478 (04) : 770 - 776
  • [10] CORR Insights®: Does Screw Location Affect the Risk of Subtrochanteric Femur Fracture After Femoral Neck Fixation? A Biomechanical Study
    Firoozabadi, Reza
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2020, 478 (04) : 777 - 778