Upgrade of the Beamline 10.0.1 at the Advanced Light Source

被引:2
|
作者
Ali, Zulfiqar [1 ]
Chuang, Yi-De [1 ]
Kilcoyne, David [1 ]
Aguilar, Alejandro [1 ]
Mo, Sung-Kwan [1 ]
Hussain, Zahid [1 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
来源
ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VII | 2012年 / 8502卷
关键词
Beamline; ARPES; SGM; SHADOW; ray tracing; X-ray optics; UNDULATOR BEAMLINE; HIGH-RESOLUTION; PERFORMANCE;
D O I
10.1117/12.930328
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Beamline 10.0.1 delivers the photons from a 4.5 m long 10 cm periodicity undulator (U100) to various endstations in its three branchlines. The beamline uses a spherical grating monochromator (SGM) to produce high energy resolution photon beam, with three gratings to cover the photon energy range from 17 to 340 eV. Typically, angle-resolved photoemission (ARPES) measurements use 30-70 eV photons. The beam size at the High Energy Resolution Spectroscopy (HERS) endstation, designed for ARPES, is measured to be 250 mu m (H) by 100 mu m (V). Due to grazing incidence geometry in the HERS endstation, the photon beam will have a large projection on the sample surface which could lead to degradation of experimental resolutions. We are in the process of designing and replacing some of the existing mirrors to improve the focus spot at HERS endstation. The detailed design parameters and possible upgrade paths will be presented with verifications using SHADOW ray-tracing program.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Beam measurements and upgrade at BL 7.2, the second diagnostics beamline of the advanced light source
    Scarvie, T
    Sannibale, F
    Biocca, A
    Kelez, N
    Martin, MC
    Nishimura, T
    Portmann, G
    Williams, E
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 2613 - 2615
  • [2] The Materials Science beamline upgrade at the Swiss Light Source
    Willmott, P. R.
    Meister, D.
    Leake, S. J.
    Lange, M.
    Bergamaschi, A.
    Boege, M.
    Calvi, M.
    Cancellieri, C.
    Casati, N.
    Cervellino, A.
    Chen, Q.
    David, C.
    Flechsig, U.
    Gozzo, F.
    Henrich, B.
    Jaeggi-Spielmann, S.
    Jakob, B.
    Kalichava, I.
    Karvinen, P.
    Krempasky, J.
    Luedeke, A.
    Luescher, R.
    Maag, S.
    Quitmann, C.
    Reinle-Schmitt, M. L.
    Schmidt, T.
    Schmitt, B.
    Streun, A.
    Vartiainen, I.
    Vitins, M.
    Wang, X.
    Wullschleger, R.
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 667 - 682
  • [3] The advanced light source upgrade
    Chemla, DS
    Feinberg, B
    Hussain, Z
    Krebs, GF
    Padmore, HA
    Robin, DS
    Robinson, AL
    Smith, NV
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 145 - 148
  • [4] Dynamics beamline at the advanced light source
    Heimann, PA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 277 - PHYS
  • [5] Superbend upgrade at the advanced light source
    Robin, D
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 224 - 228
  • [6] Superbend upgrade on the Advanced Light Source
    Robin, D
    Krupnick, J
    Schlueter, R
    Steier, C
    Marks, S
    Wang, B
    Zbasnik, J
    Benjegerdes, R
    Blocca, A
    Bish, P
    Henderson, T
    Hinkson, J
    Hoyer, E
    Hull, D
    Jacobson, S
    McDonald, J
    Molinari, P
    Mueller, R
    Nadolski, L
    Nishimura, H
    Nishimura, K
    Ottens, F
    Paterson, JA
    Pipersky, JA
    Portmann, G
    Ritchie, A
    Rossi, S
    Salvant, B
    Scarvie, T
    Schmidt, A
    Spring, J
    Taylor, C
    Thur, W
    Timossi, C
    Wandesforde, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 538 (1-3): : 65 - 92
  • [7] Beamline for macromolecular crystallography at the advanced light source
    Univ of California, Berkeley, United States
    Rev Sci Instrum, 2 pt 2 (1738-1740):
  • [8] A BEAMLINE FOR MACROMOLECULAR CRYSTALLOGRAPHY AT THE ADVANCED LIGHT-SOURCE
    PADMORE, HA
    EARNEST, T
    KIM, SH
    THOMPSON, A
    ROBINSON, AL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1738 - 1740
  • [9] The advanced light source (ALS) slicing undulator beamline
    Heimann, P. A.
    Glover, T. E.
    Plate, D.
    Lee, H. J.
    Brown, V. C.
    Padmore, H. A.
    Schoenlein, R. W.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1195 - +
  • [10] Noise reduction for the infrared beamline at the Advanced Light Source
    Byrd, JM
    Chin, M
    Martin, M
    McKinney, W
    Miller, R
    ACCELERATOR-BASED SOURCES OF INFRARED AND SPECTROSCOPIC APPLICATIONS, 1999, 3775 : 58 - 64