Mechanical characteristics of the maxillary sinus Schneiderian membrane ex vivo

被引:17
|
作者
Insua, Angel [1 ,2 ]
Monje-Gil, Florencio [3 ]
Garcia-Caballero, Lucia [4 ]
Caballe-Serrano, Jordi [5 ]
Wang, Hom-Lay [1 ]
Monje, Alberto [1 ,6 ,7 ]
机构
[1] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[2] Univ Santiago de Compostela, Sch Med & Dent, Dept Oral Surg & Oral Med, Entrerrios S-N, Santiago De Compostela 15782, Spain
[3] Hosp Infanta Cristina, Dept Oral & Maxillofacial Surg, Badajoz, Spain
[4] Univ Santiago de Compostela, Hlth Res Inst Santiago de Compostela IDIS, Med Surg Dent Res Grp OMEQUI, Santiago De Compostela, Spain
[5] Univ Int Catalunya, Dept Oral & Maxillofacial Surg, Barcelona, Spain
[6] Univ Bern, ZMK Sch Dent, Dept Oral Surg & Stomatol, Bern, Switzerland
[7] Univ Int Catalunya, Dept Periodontol, Barcelona, Spain
关键词
Dental implants; Grafting; Bone; Alveolar ridge augmentation; Maxillary sinus floor augmentation; FLOOR ELEVATION PROCEDURES; CLINICAL-IMPLICATIONS; AUGMENTATION; IMPLANTS; PERFORATION; THICKNESS; SURVIVAL; COMBINATION; SUCCESS;
D O I
10.1007/s00784-017-2201-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
It has been speculated that certain Schneiderian membrane thickness (SMT) might be more prone to perforation. This investigation was aimed at studying the mechanical characteristics of the Schneiderian membrane under one- and two-dimensional tests and their correlation to the histological SMT in human samples. Sixteen Schneiderian membranes were collected from 11 cadaver heads treated with Thiel's embalming method. The samples were processed and analyzed clinically and histologically. One-dimensional maximum elongation until perforation and two-dimensional resistance to ball penetration were performed after the biopsy. Data was analyzed by using the Wilcoxon rank test and the Spearman's rank correlation. The histological SMT was 1.36 +/- 0.42 mm, whereas the clinical thickness was 0.27 +/- 0.21 mm, yielding statistical significance (p = 0.000). The resistance under ball penetration was 0.59 +/- 0.43 N and the mean maximum elongation in the one-dimension test 11.19 +/- 7.14 mm. Expressed in percentage, the mean stretch was 241.36 +/- 227.97% (range 31.5 up to 947%). A weak positive correlation was found between the ball penetration test and the SMT (r = 0.10, p = 0.711), while a weak negative correlation was found between stretching test and the SMT (r = -0.021, p = 0.94). Mechanical tests seem to indicate that SMT might not significantly predispose to Schneiderian membrane perforation. Hence, other anatomical and operator's factors should be considered of surpassing importance. Thinner SM might be more prone to perforation when detaching it from the maxillary sinus antrum; however, a thick membrane is not prevented to tear, as their resistance under elastic forces is not higher than thinner ones.
引用
收藏
页码:1139 / 1145
页数:7
相关论文
共 50 条
  • [1] Mechanical characteristics of the maxillary sinus Schneiderian membrane ex vivo
    Angel Insua
    Florencio Monje-Gil
    Lucía García-Caballero
    Jordi Caballé-Serrano
    Hom-Lay Wang
    Alberto Monje
    Clinical Oral Investigations, 2018, 22 : 1139 - 1145
  • [2] Maxillary Sinus Septa and Anatomic Correlation With the Schneiderian Membrane
    Rancitelli, Davide
    Borgonovo, Andrea Enrico
    Cicciu, Marco
    Re, Dino
    Rizza, Federica
    Frigo, Anna Chiara
    Maiorana, Carlo
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (04) : 1394 - 1398
  • [3] Association of Inflammatory Status and Maxillary Sinus Schneiderian Membrane Thickness
    Angel Insua
    Alberto Monje
    Hsun-Liang Chan
    Hom-Lay Wang
    Clinical Oral Investigations, 2018, 22 : 245 - 254
  • [4] Association of Inflammatory Status and Maxillary Sinus Schneiderian Membrane Thickness
    Insua, Angel
    Monje, Alberto
    Chan, Hsun-Liang
    Wang, Hom-Lay
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (01) : 245 - 254
  • [5] Postoperative Perforation of the Schneiderian Membrane in Maxillary Sinus Augmentation: A Case Report
    Jo, Kyu-Hong
    Yoon, Kyu-Ho
    Cheong, Jeong-Kwon
    Jeon, In-Seong
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 : 375 - 379
  • [6] Influence of the Periapical Status of the Posterior Maxillary Teeth on the Width of the Schneiderian Membrane of the Maxillary Sinus Mucosa
    Tsesis, Igor
    Rosen, Eyal
    Beitlitum, Ilan
    Dicker-Levy, Einat
    Matalon, Shlomo
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [7] Schneiderian membrane perforation via transcrestal sinus floor elevation: A randomized ex vivo study with endoscopic validation
    Gargallo-Albiol, Jordi
    Tattan, Mustafa
    Sinjab, Khaled H.
    Chan, Hsun-Liang
    Wang, Hom-Lay
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (01) : 11 - 19
  • [8] Effect of Schneiderian Membrane Thickening on the Maxillary Sinus Augmentation and Implantation Outcomes: A Systematic Review
    Amid, Reza
    Kadkhodazadeh, Mahdi
    Moscowchi, Anahita
    Nami, Majedeh
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2021, 20 (04): : 534 - 544
  • [9] Effect of Schneiderian Membrane Thickening on the Maxillary Sinus Augmentation and Implantation Outcomes: A Systematic Review
    Reza Amid
    Mahdi Kadkhodazadeh
    Anahita Moscowchi
    Majedeh Nami
    Journal of Maxillofacial and Oral Surgery, 2021, 20 : 534 - 544
  • [10] Relationship among Schneiderian Membrane, Underwood's Septa, and the Maxillary Sinus Inferior Border
    Cakur, Binali
    Sumbullu, Muhammed Akif
    Durna, Dogan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (01) : 83 - 87