Comparative 3-E (Energy, Exergy & Environmental) Analysis of Oxy-Coal and Air-Coal Combustion based 500 MWe Supercritical Steam Power Plants with CO2 Capture

被引:1
|
作者
Chatterjee, Soumya Jyoti [1 ]
Khankari, Goutam [2 ]
Karmakar, Sujit [1 ]
机构
[1] Natl Inst Technol Durgapur, Dept Mech Engn, Durgapur 713209, W Bengal, India
[2] Damodar Valley Corp, Mejia Thermal Power Stn, Kolkata 722183, W Bengal, India
基金
中国国家自然科学基金;
关键词
Air-coal combustion; CO2; capture; Oxy-coal combustion; Supercritical; Power plant; WASTE HEAT; FUEL;
D O I
10.33889/IJMEMS.2020.5.4.053
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The comparative performance study is carried out for 500 MW Supercritical (SupC) Oxy-Coal Combustion (OCC) and Air-Coal Combustion (ACC) power plants with membrane-based CO2 capture at the fixed furnace temperature. The proposed configurations are modelled using a computer-based analysis software 'Cycle-Tempo' at different operating conditions, and the detailed thermodynamic study is done by considering Energy, Exergy, and Environmental (3-E) analysis. The result shows that the net energy and exergy efficiencies of ACC power plants with CO2 capture are about 35.07 % and 30.88 %, respectively, which are about 6.44 % and 5.77 % points, respectively higher than that of OCC power plant. Auxiliary power consumption of OCC based power plant is almost 1.97 times more than that of the ACC based plant due to huge energy utilization in the Air Separation Unit (ASU) of OCC plant which leads to performance reduction in OCC plant. However, environmental benefit of OCC based power plant is more than that of ACC based power plant with respect to CO2 emission. OCC plant emits about 0.164 kg/kWh of CO2 which is approximately 16.75 times lower than the CO2 emission in ACC based power plant. It is also analyzed that the performance of the CO2 Capture Unit (CCU) for the OCC based plant is about 3.65 times higher than the ACC based power plant due to higher concentration of CO2 (nearly 80.63%) in the flue gas emitting from OCC plant. The study also reveals that the auxiliary power consumption per kg of CO2 capture of the OCC based plant is about 0.142 kWh/kg, which is approximately 0.06 times lower than the ACC based plant. The higher performance of the OCC based power plant is found at lower value of flue gas recirculation due to the fact that reduction in exergy destruction at the mixing zone of the combustor is higher than the increase in exergy destruction of the heat exchangers at higher furnace exit temperature. But the metallurgical temperature limit of boiler tube materials restricts the use of the higher value of furnace temperature. OCC based power plant with CO2 capture can be preferred over ACC based plant with CO2 capture due to higher environmental benefits towards mitigating CO2 , the key greenhouse gas on earth in spite of exhibiting lesser energy and exergy efficiencies.
引用
收藏
页码:652 / 662
页数:11
相关论文
共 50 条
  • [1] Integrating compressed CO2 energy storage in an oxy-coal combustion power plant with CO2 capture
    Huang, Qingxi
    Yao, Jinduo
    Hu, Yukun
    Liu, Shengchun
    Li, Hailong
    Sun, Qie
    ENERGY, 2022, 254
  • [2] System Analysis on Supercritical CO2 Power Cycle with Circulating Fluidized Bed Oxy-Coal Combustion
    SHI Yan
    ZHONG Wenqi
    SHAO Yingjuan
    XIANG Jun
    Journal of Thermal Science, 2019, 28 (03) : 505 - 518
  • [3] System Analysis on Supercritical CO2 Power Cycle with Circulating Fluidized Bed Oxy-Coal Combustion
    Yan Shi
    Wenqi Zhong
    Yingjuan Shao
    Jun Xiang
    Journal of Thermal Science, 2019, 28 : 505 - 518
  • [4] System Analysis on Supercritical CO2 Power Cycle with Circulating Fluidized Bed Oxy-Coal Combustion
    Shi Yan
    Zhong Wenqi
    Shao Yingjuan
    Xiang Jun
    JOURNAL OF THERMAL SCIENCE, 2019, 28 (03) : 505 - 518
  • [5] Coal Based Power Plants Using Oxy-Combustion for CO2 Capture: Pressurized Coal Combustion to Reduce Capture Penalty
    Soundararajan, Rengarajan
    Gundersen, Truls
    PRES 2012: 15TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, 2012, 29 : 187 - 192
  • [6] Coal based power plants using oxy-combustion for CO2 capture: Pressurized coal combustion to reduce capture penalty
    Soundararajan, Rengarajan
    Gundersen, Truls
    APPLIED THERMAL ENGINEERING, 2013, 61 (01) : 115 - 122
  • [7] Perspectives of oxy-coal power plants equipped with CO2 capture, utilization, and storage in terms of energy, economic, and environmental impacts
    Kim, Semie
    Lim, Young-Il
    Lee, Doyeon
    Cho, Wonchul
    Seo, Myung Won
    Lee, Jae Goo
    Ok, Yong Sik
    ENERGY CONVERSION AND MANAGEMENT, 2022, 273
  • [8] Reducing the Power Penalty Related to CO2 Conditioning in Oxy-coal Combustion Plants by Pinch Analysis
    Fu, Chao
    Gundersen, Truls
    PRES 2011: 14TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1 AND 2, 2011, 25 : 581 - 586
  • [9] Effects of flue gas recirculation on energy, exergy, environment, and economics in oxy-coal circulating fluidized-bed power plants with CO2 capture
    Kim, Semie
    Lim, Young-Il
    Lee, Doyeon
    Seo, Myung Won
    Mun, Tae-Young
    Lee, Jae-Goo
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (04) : 5852 - 5865
  • [10] Simulation and comparative exergy analyses of oxy-steam combustion and O2/CO2 recycled combustion pulverized-coal-fired power plants
    Sheng, Lei
    Liu, Xiaowei
    Si, Junping
    Xu, Yishu
    Zhou, Zijian
    Xu, Minghou
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2014, 27 : 267 - 278