Voltage harmonic distortion at buses feeding office loads

被引:0
|
作者
Demoulias, Charis [1 ]
Goutzamanis, Dimitris [2 ,3 ]
Gouramanis, Kostas [2 ]
机构
[1] Aristotle Univ Thessaloniki, Elect Machines Lab, Dept Elect & Comp Engn, Thessaloniki, Greece
[2] Aristotle Univ Thessaloniki, Thessaloniki, Greece
[3] Alteren SA, Thessaloniki, Greece
关键词
harmonics; voltage harmonic distortion; cable impedance; cable configuration;
D O I
10.1109/PCT.2007.4538545
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The total harmonic distortion of the phase-to-neutral voltage at buses feeding office load is investigated for various cable configurations, lengths and cross-sections. The investigation is carried out with a software model which was validated with approximate analytical expressions and measurements taken at a real installation. It is shown that the selection of a cable should based not only on its ampacity and allowable voltage drop but its configuration should be taken into account in order to avoid excessive voltage harmonic distortion. Configurations where the neutral conductor is part of a four-core cable cause relatively small harmonic distortion while cable configurations where the neutral conductor runs separately cause high voltage harmonic distortion.
引用
收藏
页码:1546 / +
页数:2
相关论文
共 50 条
  • [1] Analysis of the voltage harmonic distortion at buses feeding office loads
    Demoulias, C.
    Goutzamanis, D.
    Gouramanis, K.
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2009, 3 (04) : 286 - 301
  • [2] Voltage multiple-zero-crossings at buses feeding large Triac-Controlled loads
    Demoulias, Charis
    Gouramanis, Kostas
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (05) : 2853 - 2863
  • [3] Harmonic current and voltage distortion
    Lowenstein, Michael Z.
    EC and M: Electrical Construction and Maintenance, 2002, 101 (11): : 32 - 38
  • [4] Optimal C-Type Passive Filter Based on Minimization of the Voltage Harmonic Distortion for Nonlinear Loads
    Aleem, Shady Hossam Eldeen Abdel
    Zobaa, Ahmed Faheem
    Aziz, Mohamed Mamdouh Abdel
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (01) : 281 - 289
  • [6] VOLTAGE DISTORTION IN DISTRIBUTION FEEDERS WITH NONLINEAR LOADS
    EMANUEL, AE
    JANCZAK, J
    PILEGGI, DJ
    GULACHENSKI, EM
    ROOT, CE
    BREEN, M
    GENTILE, TJ
    IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (01) : 79 - 85
  • [7] Voltage distortion in distribution feeders with nonlinear loads
    Emanuel, A.E.
    Janczak, J.
    Pileggi, D.J.
    Gulachenski, E.M.
    Root, C.E.
    Breen, M.
    Gentile, T.J.
    IEEE Power Engineering Review, 1994, 14 (01):
  • [8] CURRENT HARMONIC DISTORTION IN OFFICE BUILDING ELECTRIC NETWORK
    Albu, Horatiu
    Pop, Florin
    QUALITY AND INNOVATION IN ENGINEERING AND MANAGEMENT, 2011, : 379 - 382
  • [9] Voltage harmonic distortion measurements using capacitive voltage transformers
    Vermeulen, HJ
    Davel, P
    AFRICON '96 - 1996 IEEE AFRICON : 4TH AFRICON CONFERENCE IN AFRICA, VOLS I & II: ELECTRICAL ENERGY TECHNOLOGY; COMMUNICATION SYSTEMS; HUMAN RESOURCES, 1996, : 1012 - 1017
  • [10] Analysis of high voltage harmonic distortion measurements
    Etezadi-Amoli, M.
    Choma, K.
    Louie, R.
    2007 39TH NORTH AMERICAN POWER SYMPOSIUM, VOLS 1 AND 2, 2007, : 511 - 517