ROBUST ALGORITHM FOR DENOISING OF PHOTON-LIMITED DUAL-ENERGY CONE BEAM CT PROJECTIONS

被引:0
|
作者
Zavala-Mondragon, Luis A. [1 ]
van der Sommen, Fons [1 ]
Ruijters, Danny [2 ]
Engel, Klaus J. [3 ]
Steinhauser, Heidrun [2 ]
de With, Peter H. N. [1 ]
机构
[1] Eindhoven Univ Technol, Eindhoven, Netherlands
[2] Philips Healthcare, Amsterdam, Netherlands
[3] Philips Elect Netherlands, Amsterdam, Netherlands
关键词
Image denoising; Cone Beam CT; Dual Energy CT;
D O I
10.1109/isbi45749.2020.9098442
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dual-Energy CT offers significant advantages over traditional CT imaging because it offers energy-based awareness of the image content and facilitates material discrimination in the projection domain. The Dual-Energy CT concept has intrinsic redundancy that can be used for improving image quality, by jointly exploiting the high- and low-energy projections. In this paper we focus on noise reduction. This work presents the novel noise-reduction algorithm Dual Energy Shifted Wavelet Denoising (DESWD), which renders high-quality Dual-Energy CBCT projections out of noisy ones. To do so, we first apply a Generalized Anscombe Transform, enabling us to use denoising methods proposed for Gaussian noise statistics. Second, we use a 3D transformation to denoise all the projections at once. Finally we exploit the inter-channel redundancy of the projections to create sparsity in the signal for better denoising with a channel-decorrelation step. Our simulation experiments show that DESWD performs better than a state-of-the-art denoising method (BM4D) in limited photon-count imaging, while BM4D achieves excellent results for less noisy conditions.
引用
收藏
页码:867 / 871
页数:5
相关论文
共 50 条
  • [1] Fast and effective single-scan dual-energy cone-beam CT reconstruction and decomposition denoising based on dual-energy vectorization
    Jiang, Xiao
    Fang, Chengyijue
    Hu, Panpan
    Cui, Hehe
    Zhu, Lei
    Yang, Yidong
    MEDICAL PHYSICS, 2021, 48 (09) : 4843 - 4856
  • [2] Dual-energy approach to reduce cone-beam artefacts in a circular orbit cone-beam CT system
    Han, C.
    Baek, J.
    ELECTRONICS LETTERS, 2020, 56 (13) : 648 - 650
  • [3] Feasibility of direct electron density determination using dual-energy cone beam CT
    Schroder, L.
    Stankovic, U.
    Fast, M. F.
    Sonke, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1183 - S1184
  • [4] Contrast-Enhanced Dual-Energy Cone-Beam CT for Musculoskeletal Radiology
    Zbijewski, W.
    Stayman, J.
    Ding, Y.
    Prakash, P.
    Machado, A.
    Carrino, J.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [5] Cascaded systems analysis of noise and detectability in dual-energy cone-beam CT
    Gang, Grace J.
    Zbijewski, Wojciech
    Stayman, J. Webster
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2012, 39 (08) : 5145 - 5156
  • [6] Application of dual-energy techniques to helical, cone-beam CT image reconstruction
    Sidky, E
    Zou, Y
    Pan, X
    MEDICAL PHYSICS, 2003, 30 (06) : 1408 - 1408
  • [7] Low-dose dual-energy cone-beam CT using a total-variation minimization algorithm
    Min, Jonghwan
    Lee, Taewon
    Kim, Kyungwoo
    Cho, Gyuseong
    Cho, Seungryong
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [8] Dual-energy cone-beam CT with a flat-panel detector: Effect of reconstruction algorithm on material classification
    Zbijewski, W.
    Gang, G. J.
    Xu, J.
    Wang, A. S.
    Stayman, J. W.
    Taguchi, K.
    Carrino, J. A.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2014, 41 (02)
  • [9] Image quality of dual-energy cone-beam CT with total nuclear variation regularization
    Schroder, Lukas
    Stankovic, Uros
    Rit, Simon
    Sonke, Jan-Jakob
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (02):
  • [10] Dual-energy cone-beam Micro-CT for animal imaging: Preliminary study
    Cho, Seungryong
    Sidky, Emil
    Bian, Junguo
    Pan, Xiaochuan
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510