Detection of Parathyroid Autofluorescence Using Near-Infrared Imaging: A Multicenter Analysis of Concordance Between Different Surgeons

被引:105
|
作者
Kahramangil, Bora [1 ]
Dip, Fernando [2 ,3 ]
Benmiloud, Fares [4 ]
Falco, Jorge [2 ]
de La Fuente, Martin [2 ]
Verna, Silvina [2 ]
Rosenthal, Raul [3 ]
Berber, Eren [1 ]
机构
[1] Cleveland Clin, Dept Endocrine Surg, Cleveland, OH 44106 USA
[2] IADT, Buenos Aires, DF, Argentina
[3] Cleveland Clin Florida, Dept Surg, Weston, FL 33331 USA
[4] Hop Europeen, Dept Endocrine Surg, Marseille, France
关键词
GAMMA-PROBE IDENTIFICATION; CENTRAL NECK-SURGERY; THYROID-SURGERY; GLANDS; HYPERPARATHYROIDISM; PRESERVATION; FLUORESCENCE; SPECTROSCOPY; UTILITY;
D O I
10.1245/s10434-018-6364-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Parathyroid glands (PGs) exhibit autofluorescence (AF) when excited by near-infrared laser. This multicenter study aims to analyze how this imaging could facilitate the detection of PGs during thyroidectomy and parathyroidectomy procedures. This was a retrospective Institutional Review Board-approved analysis of prospectively collected data at three centers. Near-infrared fluorescence imaging (NIFI) was used to detect AF from PGs during thyroidectomy and parathyroidectomy procedures. Logistic regression analysis was performed to assess the utility of NIFI to identify PGs and concordance at these centers. Overall, 210 patients underwent total thyroidectomy (n = 95), thyroid lobectomy (n = 41), and parathyroidectomy (n = 74) (n = 70 per center). Using NIFI, AF was detected from 98% of visually identified PGs. Upon initial exploration, 46% of PGs were not visible to the naked eye due to coverage by soft tissue, but AF from these glands could be detected by NIFI without any further dissection. Overall, a median of one PG per patient was detected by NIFI in this fashion before being identified visually (p = nonsignificant between centers). On logistic regression, smaller PGs were more likely to be missed visually, but localized by AF on NIFI (odds ratio with increasing size, 0.91; p = 0.02). In our experience, NIFI facilitated PG identification by detecting their AF, before conventional recognition by the surgeon, in 37-67% of the time. Despite the variability in this rate across centers, there was a concordance in detecting AF from 97 to 99% of the PGs using NIFI. We suggest the incorporation of AF on NIFI alongside conventional visual cues to aid identification of PGs during neck operations.
引用
收藏
页码:957 / 962
页数:6
相关论文
共 50 条
  • [1] Detection of Parathyroid Autofluorescence Using Near-Infrared Imaging: A Multicenter Analysis of Concordance Between Different Surgeons
    Bora Kahramangil
    Fernando Dip
    Fares Benmiloud
    Jorge Falco
    Martin de La Fuente
    Silvina Verna
    Raul Rosenthal
    Eren Berber
    Annals of Surgical Oncology, 2018, 25 : 957 - 962
  • [2] A multicenter evaluation of near-infrared autofluorescence imaging of parathyroid glands in thyroid and parathyroid surgery
    Sehnem, Ludovico, Jr.
    Noureldine, Salem, I
    Avci, Seyma
    Isiktas, Gizem
    Elshamy, Mohammed
    Saito, Yoshiyuki
    Ahmed, Amr H. A.
    Tierney, Hien T.
    Trinh, Lily N.
    Karcioglu, Amanda Silver
    Cheung, Anthony Y.
    Otremba, Michael
    Krishnamurthy, Vikram
    Heiden, Katherine
    Jin, Judy
    Shin, Joyce
    Siperstein, Allan
    Zafereo, Mark
    Tufano, Ralph P.
    Randolph, Gregory W.
    Kebebew, Electron
    Milas, Mira
    Duh, Quan-Yang
    Berber, Eren
    SURGERY, 2023, 173 (01) : 132 - 137
  • [3] Near-infrared autofluorescence for the detection of parathyroid glands
    Paras, Constantine
    Keller, Matthew
    White, Lisa
    Phay, John
    Mahadevan-Jansen, Anita
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (06)
  • [4] Intraoperative near-infrared autofluorescence imaging of parathyroid glands
    Ladurner, Roland
    Sommerey, Sandra
    Al Arabi, Nora
    Hallfeldt, Klaus K. J.
    Stepp, Herbert
    Gallwas, Julia K. S.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2017, 31 (08): : 3140 - 3145
  • [5] Intraoperative near-infrared autofluorescence imaging of parathyroid glands
    Roland Ladurner
    Sandra Sommerey
    Nora Al Arabi
    Klaus K. J. Hallfeldt
    Herbert Stepp
    Julia K. S. Gallwas
    Surgical Endoscopy, 2017, 31 : 3140 - 3145
  • [6] Near-infrared autofluorescence imaging for detection of cancer
    Demos, SG
    Gandour-Edwards, R
    Ramsamooj, R
    White, RD
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (03) : 587 - 592
  • [7] ASO Author Reflections: Parathyroid Autofluorescence and Near-Infrared Imaging
    Kahramangil, Bora
    Berber, Eren
    ANNALS OF SURGICAL ONCOLOGY, 2018, 25 : 876 - 877
  • [8] ASO Author Reflections: Parathyroid Autofluorescence and Near-Infrared Imaging
    Bora Kahramangil
    Eren Berber
    Annals of Surgical Oncology, 2018, 25 : 876 - 877
  • [9] Analysis of near-infrared autofluorescence imaging for detection of inadvertently resected parathyroid glands after endoscopic thyroidectomy
    Kuo, Ting-Chun
    Chen, Kuen-Yuan
    Lai, Chieh-Wen
    Lin, Ming-Tsan
    Chang, Chin-Hao
    Wu, Ming-Hsun
    EJSO, 2024, 50 (11):
  • [10] Near-infrared autofluorescence imaging to detect parathyroid glands in thyroid surgery
    Ladurner, R.
    Al Arabi, N.
    Guendogar, U.
    Hallfeldt, K. K. J.
    Stepp, H.
    Gallwas, J. K. S.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2018, 100 (01) : 33 - 36