Novel Time Synchronization Method based on Duo-Satellite Triggering for Double-Ended PD Location in MV Cables

被引:0
|
作者
Li, Baojie [1 ]
Li, Hongjie [1 ]
Zeng, Xiangfeng [1 ]
He, Weisheng [1 ]
Zeng, Xiaoming [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat Power Equipment, Xian, Shaanxi, Peoples R China
关键词
Time synchronization; Double-ended; GPS & BDS triggering; Partial Discharge; PD location; MV cables; PARTIAL DISCHARGE LOCATION; GPS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recent years, double-ended techniques for PD location in MV cables emerged in large numbers. Nevertheless, great majority of the methods face the challenge of the time-synchronization between the two cable terminals because of the satellite invisibility and atmospheric condition problems in the global positioning system (GPS) receiver. Conventional methods adopt free running 1PPS to synchronize system clock, which in addition generates large volume of datasets and increases the hardware cost. Based on IEEE 1588, this paper therefore proposes a Round-Trip Communication (RTC) algorithm implemented in two portable cost-effective PD location devices developed specially for double-end measurement system based on the combination of both GPS and BeiDou Navigation Satellite (BDS) signals. A particular 1PPS is adopted as transfer signal between the two devices on considering the time margin and communication delay so that the starting record time could be synchronized. The performance of this proposed technique is evaluated via laboratory tests, and the results indicate that the average error of time offset is reduced to great extent. Key points of future research work are highlighted at the end of paper.
引用
收藏
页码:436 / 439
页数:4
相关论文
共 7 条
  • [1] Partial Discharge Location in Power Cables using a Double Ended Method Based on Time Triggering with GPS
    Mohamed, F. P.
    Siew, W. H.
    Soraghan, J. J.
    Strachan, S. M.
    McWilliam, J.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 2212 - 2221
  • [2] Impact of an inverter-based DG on a double-ended fault location method
    Jahanger, Hayder K.
    Thomas, David W. P.
    Sumner, Mark
    Rose, Christopher
    JOURNAL OF ENGINEERING-JOE, 2018, (15): : 1078 - 1083
  • [3] A Novel Double Ended Method for Fault Location Based on Travelling Wave Time-series
    Jin, Wei
    Lu, Yuping
    Tang, Cheng
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2016,
  • [4] A novel fault location scheme for multi-terminal transmission lines based on principle of double-ended traveling wave
    Fan, Xinqiao
    Zhu, Yongli
    Dianwang Jishu/Power System Technology, 2013, 37 (01): : 261 - 269
  • [5] A novel method of high impedance fault detection and fault resistance calculation based on damping rate double-ended measurement for distribution network
    Yu, Kun
    Yu, Quan
    Zeng, Xiangjun
    Zeng, Jupeng
    Ni, Yanru
    Zou, Hao
    Liu, Feng
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 136
  • [6] Fault Location Method for Power Supply Rails in Low and Medium-speed Magnetic Levitation Traffic Based on Double-ended Traveling Wave Frequency Variation Characteristics
    Yan N.
    Wang J.
    Qin C.
    Ping A.
    Li Q.
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (04): : 1526 - 1537
  • [7] Improved Double-Sided Partial Discharge Location Method for High-Voltage Cables via Pulse-Injected Time Synchronization and Variational Mode Decomposition
    Chen, Junbai
    Yan, Yuan
    Zhao, Kun
    Zhu, Mengxin
    Wang, Li
    Lu, Yuxin
    Hou, Zhe
    Li, Hongjie