Lung function measurement with multiple-breath-helium washout system

被引:2
|
作者
Wang, J. -Y. [1 ]
Suddards, M. E. [1 ]
Mellor, C. J. [1 ]
Owers-Bradley, J. R. [1 ]
机构
[1] Univ Nottingham, Sch Phys & Astron, Nottingham NG7 2RD, England
基金
英国惠康基金;
关键词
Respiratory gas sensing; Lung function; Multiple breath washout; Helium gas detector; MULTIBREATH NITROGEN WASHOUT; ULTRASONIC FLOW SENSOR; CLEARANCE INDEX; VENTILATION INHOMOGENEITIES; PULMONARY VENTILATION; TUNING FORK; GAS; HEALTHY; DISEASE; VOLUME;
D O I
10.1016/j.medengphy.2012.06.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multiple-breath-washout (MBW) measurements are regarded as a sensitive technique which can reflect the ventilation inhomogeneity of respiratory airways. Typically nitrogen is used as the tracer gas and is washed out by pure oxygen in multiple-breath-nitrogen washout (MBNW) tests. In this study, instead of using nitrogen, He-4 is used as the tracer gas with smaller gas density which may be able to reach deeper into our lungs in a given time and the helium washout results may be more sensitive to the ventilation inhomogeneity in small airways. A multiple-breath-helium-washout (MBHW) system developed for the lung function study is also presented. Quartz tuning forks with a resonance frequency of 32,768 Hz have been used for detecting the change of the respiratory gas density. The resonance frequency of the quartz tuning fork decreases linearly with increasing density of the surrounding gas. Knowing the CO2 concentration from the infrared carbon dioxide detector, the helium concentration can be determined. Results from 14 volunteers (3 mild asthmatics, 4 tobacco smokers, 1 with asthma history, 1 with COPD history, 5 normal) have shown that mild asthmatics have higher ventilation inhomogeneity in either conducting or acinar airways (or both). A feature has been found in washout curve of single breaths from 4 tobacco smokers with different length of smoking history which may indicate the early stage of respiratory ventilation inhomogeneity in acinar airways. (C) 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:457 / 469
页数:13
相关论文
共 50 条
  • [1] Simultaneous measurement of multiple breath washout and functional lung MRI
    Kentgens, Anne-Christianne
    Pusterla, Orso
    Pusterla, Orso
    Pusterla, Orso
    Pusterla, Orso
    Bauman, Grzegorz
    Bauman, Grzegorz
    Santini, Francesco
    Santini, Francesco
    Willers, Christoph Corin
    Bieri, Oliver
    Bieri, Oliver
    Latzin, Philipp
    Ramsey, Kathryn
    EUROPEAN RESPIRATORY JOURNAL, 2021, 58
  • [2] Multiple breath helium dilution measurement of lung volumes in adults
    Brown, R
    Leith, DE
    Enright, PL
    EUROPEAN RESPIRATORY JOURNAL, 1998, 11 (01) : 246 - 255
  • [3] Global Lung Function Initiative reference values for multiple breath washout indices
    Ramsey, Kathryn A.
    Stanojevic, Sanja
    Chavez, Luis
    Johnson, Noah
    Bowerman, Cole
    Hall, Graham L.
    Latzin, Philipp
    O'Neill, Katherine
    Robinson, Paul D.
    Stahl, Mirjam
    Weiner, Daniel J.
    Zwitserloot, Annelies M.
    Horsley, Alex
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64 (06)
  • [4] Bayesian modelling of lung function data from multiple-breath washout tests
    Mahar, Robert K.
    Carlin, John B.
    Ranganathan, Sarath
    Ponsonby, Anne-Louise
    Vuillermin, Peter
    Vukcevic, Damjan
    STATISTICS IN MEDICINE, 2018, 37 (12) : 2016 - 2033
  • [5] OPTIMIZING LUNG FUNCTION TESTING USING MULTIPLE BREATH WASHOUT (MBW) IN UNSEDATED INFANTS
    King, L.
    Ranganathan, S.
    Hollingworth, K.
    Hayes, S.
    Sykes, E.
    Vuillermin, P.
    RESPIROLOGY, 2013, 18 : 8 - 8
  • [6] Linking Helium-3 Mri Washout Imaging To Multiple Breath Washout - First Steps To Understanding Regional Lung Ventilation Heterogeneity
    Horn, F.
    Horsley, A.
    Marshall, H.
    Taylor, C.
    Parra-Robles, J.
    Wild, J. M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [7] Multiple breath washout: A new and promising lung function test for patients with idiopathic pulmonary fibrosis
    Nyilas, Sylvia
    Schreder, Theresa
    Singer, Florian
    Poellinger, Alexander
    Geiser, Thomas Kurt
    Latzin, Philipp
    Funke, Manuela
    RESPIROLOGY, 2018, 23 (08) : 764 - 770
  • [8] SIMULTANEOUS HELIUM AND NITROGEN SINGLE-BREATH WASHOUT - LUNG MODEL SIMULATION
    KANEKO, K
    JOURNAL OF APPLIED PHYSIOLOGY, 1978, 44 (04) : 499 - 506
  • [9] Multiple breath washout in pediatric patients after lung transplantation
    Nyilas, S.
    Carlens, J.
    Price, T.
    Singer, F.
    Mueller, C.
    Hansen, G.
    Warnecke, G.
    Latzin, P.
    Schwerk, N.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2018, 18 (01) : 145 - 153
  • [10] Multiple breath washout: measuring early manifestations of lung pathology
    Stanojevic, Sanja
    Bowerman, Cole
    Robinson, Paul
    BREATHE, 2021, 17 (03)