Thyroid Nodules with Initially Nondiagnostic Cytologic Results: The Role of Core-Needle Biopsy

被引:107
|
作者
Yeon, Jin Sun [1 ,2 ]
Baek, Jung Hwan [1 ,2 ]
Lim, Hyun Kyung [1 ,2 ]
Ha, Eun Ju [1 ,2 ]
Kim, Jae Kyun [5 ]
Song, Dong Eun [3 ]
Kim, Tae Yong [4 ]
Lee, Jeong Hyun [1 ,2 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, Seoul 138736, South Korea
[3] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Pathol, Seoul 138736, South Korea
[4] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Endocrinol & Metab, Seoul 138736, South Korea
[5] Chung Ang Univ, Coll Med, Dept Radiol, Seoul 156756, South Korea
关键词
ASPIRATION STATE; MALIGNANCY; ASSOCIATION; MANAGEMENT;
D O I
10.1148/radiol.13122247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the role of core-needle biopsy (CNB) in thyroid nodules with nondiagnostic results at previous fine-needle aspiration (FNA). Materials and Methods: From October 2008 to July 2011, 155 nodules from 155 patients (37 men, 118 women) with a mean age of 51.8 years (age range, 22-76 years) with nondiagnostic results at previous FNA were reviewed retrospectively. The Bethesda system for reporting thyroid cytopathologic results was used to assign FNA and CNB findings. Malignant nodules (n = 37) were diagnosed after surgery. Benign nodules (n = 79) were diagnosed either after surgery, with benign findings after FNA and/or CNB that had been repeated at least twice, or after benign cytology findings at FNA or CNB with a stable size at follow-up. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of ultrasonographically guided CNB were evaluated. Results: At CNB, two nodules (1.3%) showed nondiagnostic results, and 135 nodules (87.1%) had conclusive diagnoses. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of core biopsies for the detection of malignancy were 94.6% (35 of 37), 100% (79 of 79), 100% (35 of 35), 97.5% (79 of 81), and 98.3% (114 of 116), respectively. For 28 nodules, nondiagnostic results were found after two or more FNA procedures; however, diagnostic surgery was performed in only one patient. Conclusion: CNB of the thyroid nodule demonstrates high rates of conclusive and accurate diagnoses in patients for whom previous FNA results were nondiagnostic, thereby reducing the need for unnecessary diagnostic surgery. (C) RSNA, 2013
引用
收藏
页码:274 / 280
页数:7
相关论文
共 50 条
  • [1] Role of Core-Needle Biopsy in Thyroid Nodules with Initially Nondiagnostic Cytologic Results Response
    Ha, Eun Ju
    Baek, Jung Hwan
    RADIOLOGY, 2014, 270 (02) : 630 - 630
  • [2] Role of Core- Needle Biopsy in Thyroid Nodules with Initially Nondiagnostic Cytologic Results
    Qiu, Xiao-Ying
    Song, Xiang-Yang
    Huang, Zhi-Liang
    Hu, Qiao-Hong
    Chen, Shuang-Xi
    Fan, Xiao-Ming
    RADIOLOGY, 2014, 270 (02) : 628 - 630
  • [3] THE ROLE OF CORE-NEEDLE BIOPSY FOR THYROID NODULES WITH INITIALLY NONDIAGNOSTIC FINE-NEEDLE ASPIRATION RESULTS: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Suh, Chong Hyun
    Baek, Jung Hwan
    Kim, Kyung Won
    Sung, Tae Yon
    Kim, Tae Yong
    Song, Dong Eun
    Choi, Young Jun
    Lee, Jeong Hyun
    ENDOCRINE PRACTICE, 2016, 22 (06) : 679 - 688
  • [4] Sonographically Suspicious Thyroid Nodules with Initially Benign Cytologic Results: The Role of a Core Needle Biopsy
    Ha, Eun Ju
    Baek, Jung Hwan
    Lee, Jeong Hyun
    Song, Dong Eun
    Kim, Jae Kyun
    Shong, Young Kee
    Hong, Suck Joon
    THYROID, 2013, 23 (06) : 703 - 708
  • [5] The Role of Core-Needle Biopsy as a First-Line Diagnostic Tool for Initially Detected Thyroid Nodules
    Suh, Chong Hyun
    Baek, Jung Hwan
    Lee, Jeong Hyun
    Choi, Young Jun
    Kim, Jae Kyun
    Sung, Tae-Yon
    Yoon, Jong Ho
    Shong, Young Kee
    THYROID, 2016, 26 (03) : 395 - 403
  • [6] Core-needle biopsy in thyroid nodules: performance, accuracy, and complications
    Paja, Miguel
    Luis del Cura, Jose
    Zabala, Rosa
    Korta, Igone
    Ugalde, Aitziber
    Lopez, Jose, I
    EUROPEAN RADIOLOGY, 2019, 29 (09) : 4889 - 4896
  • [7] Evaluation of Modified Core-Needle Biopsy in the Diagnosis of Thyroid Nodules
    Ahn, Soomin
    Jung, Sejin
    Kim, Ji-Ye
    Shin, Jung Hee
    Hahn, Soo Yeon
    Oh, Young Lyun
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (04) : 656 - 664
  • [8] Core-needle biopsy in thyroid nodules: performance, accuracy, and complications
    Miguel Paja
    Jose Luis del Cura
    Rosa Zabala
    Igone Korta
    Aitziber Ugalde
    José I. López
    European Radiology, 2019, 29 : 4889 - 4896
  • [9] Efficacy and safety of core-needle biopsy in initially detected thyroid nodules via propensity score analysis
    Chong Hyun Suh
    Jung Hwan Baek
    Young Jun Choi
    Tae Yong Kim
    Tae Yon Sung
    Dong Eun Song
    Jeong Hyun Lee
    Scientific Reports, 7
  • [10] Efficacy and safety of core-needle biopsy in initially detected thyroid nodules via propensity score analysis
    Suh, Chong Hyun
    Baek, Jung Hwan
    Choi, Young Jun
    Kim, Tae Yong
    Sung, Tae Yon
    Song, Dong Eun
    Lee, Jeong Hyun
    SCIENTIFIC REPORTS, 2017, 7