DETECTION OF SER450LEU MUTATION IN RPOB GENE OF MYCOBACTERIUM TUBERCULOSIS BY ALLELE-SPECIFIC LOOP-MEDIATED ISOTHERMAL DNA AMPLIFICATION METHOD

被引:0
|
作者
Filipenko, M. L. [1 ]
Oscorbin, I. P. [1 ]
Khrapov, E. A. [1 ]
Shamovskaya, D., V [1 ]
Cherednichenko, A. G. [2 ]
Shvartz, Ya Sh [2 ]
机构
[1] Inst Chem Biol & Fundamental Med, Novosibirsk, Russia
[2] Novosibirsk TB Res Inst, Novosibirsk, Russia
关键词
Mycobacterium tuberculosis; drug resistance; rifampicin; rpoB gene; isothermal loop amplification; LAMP;
D O I
10.24075/brsmu.2019.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To identify genetic mutations a rather time-consuming and expensive method of polymerase chain reaction (PCR) is widely used. The aim of the present work was to evaluate the possibility of using the two schemes of the method of allele-specific isothermal loop amplification (LAMP) to detect the TCG/TTG (S450L) mutation in the rpoB gene of Mycobacterium tuberculosis. 48 clinical isolates of M. tuberculosis and 11 samples of sputum were used, randomized and obtained in the microbiological laboratory of the city of Novosibirsk from incident patients. It is shown that the use of an analysis scheme using the allele-specific primer FIP compared to F3 has the best resolution: the difference between the amplification time of the mutation and the wild type allele was 22 +/- 2,4 versus 13 +/- 4,1 minutes (c. = 0,0011). When using 100 DNA genomic equivalents a true positive signal (amplification of the rpoB gene with a mutation using the corresponding allele-specific primer) was detected after 29,4 +/- 3,4 minutes. A positive signal was visualized after adding SYBR Green Ito the reaction, both when illuminated with daylight and when using a UV transilluminator. Using the developed method the DNA sample of 20 RIP isolates from M. tuberculosis was analyzed containing the Ser450Leu mutation in the rpoB gene, 10 RIPR isolates containing other mutations in the rpoB gene and 18 RIPS isolates without any mutations; the presence of mutations in the samples was determined using classical Sanger sequencing. The sensitivity and specificity of LAMP for detecting a Ser450Leu mutation in the rpoB gene was 100%. This approach allows the use of crude lysates of mycobacteria as DNA. which reduces the total analysis time to 1,5 hour.
引用
收藏
页码:36 / 43
页数:8
相关论文
共 50 条
  • [1] Visual detection of mycobacterium tuberculosis by loop-mediated isothermal amplification
    Aryan, Ehsan
    Neshani, Alireza
    Sadeghian, Hamid
    Safdari, Hadi
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [2] Detection of Mycobacterium Tuberculosis by Loop-Mediated Isothermal Amplification Assay
    Ahn, Young-Chang
    Nam, Youn-Hyoung
    Park, Su-Min
    Cho, Min-Ho
    Seo, Jae-Won
    Yoon, Il-Kyu
    Park, Yong Hyun
    Jang, Won-Cheoul
    JOURNAL OF THE KOREAN CHEMICAL SOCIETY-DAEHAN HWAHAK HOE JEE, 2008, 52 (03): : 273 - 280
  • [3] Use of loop-mediated isothermal amplification of DNA for the rapid detection of Mycobacterium tuberculosis in clinical specimens
    Neonakis, I. K.
    Spandidos, D. A.
    Petinaki, E.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2011, 30 (08) : 937 - 942
  • [4] Use of loop-mediated isothermal amplification of DNA for the rapid detection of Mycobacterium tuberculosis in clinical specimens
    I. K. Neonakis
    D. A. Spandidos
    E. Petinaki
    European Journal of Clinical Microbiology & Infectious Diseases, 2011, 30 : 937 - 942
  • [5] Development of a loop-mediated isothermal amplification (LAMP) method for specific detection of Mycobacterium bovis
    Kapalamula, Thoko Flav
    Thapa, Jeewan
    Akapelwa, Mwangala Lonah
    Hayashida, Kyoko
    Gordon, Stephen V.
    Hang' Ombe, Bernard Mudenda
    Munyeme, Musso
    Solo, Eddie Samuneti
    Bwalya, Precious
    Nyenje, Mirriam Ethel
    Tamaru, Aki
    Suzuki, Yasuhiko
    Nakajima, Chie
    PLOS NEGLECTED TROPICAL DISEASES, 2021, 15 (01): : 1 - 15
  • [6] In-silico automated allele-specific primer design for loop-mediated isothermal amplification
    Alexandrou, George
    Rodriguez-Manzano, Jesus
    Malpartida-Cardenas, Kenny
    Georgiou, Pantelis
    Toumazou, Chris
    Kalofonou, Melpomeni
    2020 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2020,
  • [7] Microfluidic method for rapid turbidimetric detection of the DNA of Mycobacterium tuberculosis using loop-mediated isothermal amplification in capillary tubes
    Adele Rafati
    Pooria Gill
    Microchimica Acta, 2015, 182 : 523 - 530
  • [8] Microfluidic method for rapid turbidimetric detection of the DNA of Mycobacterium tuberculosis using loop-mediated isothermal amplification in capillary tubes
    Rafati, Adele
    Gill, Pooria
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 523 - 530
  • [9] Loop-mediated isothermal amplification assay for detection of Mycobacterium tuberculosis complex in infertile women
    Sethi, S.
    Dhaliwal, L.
    Dey, P.
    Kaur, H.
    Yadav, R.
    Sethi, S.
    INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2016, 34 (03) : 322 - 327
  • [10] Evaluating the use of loop-mediated isothermal amplification (LAMP) method for detection of Mycobacterium tuberculosis in Indonesian clinical isolates
    Lisdawati, Vivi
    Oshibe, Tomohiro
    Tsuji, Hidetaka
    Sudiro, Tjahjani M.
    Adianti, Myrna
    Sukarso, Triyani
    Arief, Holy
    Hotta, Hak
    Sudarmono, Pratiwi
    MEDICAL JOURNAL OF INDONESIA, 2012, 21 (04) : 188 - 195