Inconsistency in 9 mm bullets: Correlation of jacket thickness to post-impact geometry measured with non-destructive X-ray computed tomography

被引:6
|
作者
Thornby, John [1 ]
Landheer, Dirk [2 ]
Williams, Tim [2 ]
Barnes-Warden, Jane
Fenne, Paul
Norman, Daniel [1 ]
Attridge, Alex [1 ]
Williams, Mark A. [1 ]
机构
[1] Univ Warwick, WMG, Coventry CV4 7AL, W Midlands, England
[2] Simpact Engn Ltd, Warwick CV34 5DA, England
基金
英国工程与自然科学研究理事会;
关键词
Ammunition variability; Armour standard; Ballistic impact; Bullet geometry; Jacket thickness; X-ray computed tomography; TERMINAL BALLISTICS; SIMULATION; IMPACT;
D O I
10.1016/j.forsciint.2013.11.002
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Fundamental to any ballistic armour standard is the reference projectile to be defeated. Typically, for certification purposes, a consistent and symmetrical bullet geometry is assumed, however variations in bullet jacket dimensions can have far reaching consequences. Traditionally, characteristics and internal dimensions have been analysed by physically sectioning bullets - an approach which is of restricted scope and which precludes subsequent ballistic assessment. The use of a non-destructive X-ray computed tomography (CT) method has been demonstrated and validated (Kumar et al., 2011 [15]); the authors now apply this technique to correlate bullet impact response with jacket thickness variations. A set of 20 bullets (9 mm DM11) were selected for comparison and an image-based analysis method was employed to map jacket thickness and determine the centre of gravity of each specimen. Both intra-and inter-bullet variations were investigated, with thickness variations of the order of 200 mu m commonly found along the length of all bullets and angular variations of up to 50 mu m in some. The bullets were subsequently impacted against a rigid flat plate under controlled conditions (observed on a high-speed video camera) and the resulting deformed projectiles were re-analysed. The results of the experiments demonstrate a marked difference in ballistic performance between bullets from different manufacturers and an asymmetric thinning of the jacket is observed in regions of pre-impact weakness. The conclusions are relevant for future soft armour standards and provide important quantitative data for numerical model correlation and development. The implications of the findings of the work on the reliability and repeatability of the industry standard V-50 ballistic test are also discussed. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 50 条
  • [1] Inconsistency in 9 mm bullets: Correlation of jacket thickness to post-impact geometry measured with non-destructive X-ray computed tomography (vol 234, pg 111, 2014)
    Thornby, John
    Landheer, Dirk
    Williams, Tim
    Barnes-Warden, Jane
    Fenne, Paul
    Norman, Danielle
    Attridge, Alex
    Williams, Mark A.
    FORENSIC SCIENCE INTERNATIONAL, 2018, 282 : 92 - 92
  • [2] Inconsistency in 9 mm bullets measured with non-destructive X-ray computed tomography
    Kumar, Jagadeesha
    Landheer, Dirk
    Barnes-Warden, Jane
    Fenne, Paul
    Attridge, Alex
    Williams, Mark A.
    FORENSIC SCIENCE INTERNATIONAL, 2012, 214 (1-3) : 48 - 58
  • [3] X-ray Computed Tomography for Non-Destructive Failure Analysis in Microelectronics
    Pacheco, Mario
    Goyal, Deepak
    2010 INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM, 2010, : 252 - 258
  • [4] NEW POSSIBILITIES OF NON-DESTRUCTIVE EVALUATION BY X-RAY COMPUTED-TOMOGRAPHY
    REIMERS, P
    GOEBBELS, J
    MATERIALS EVALUATION, 1983, 41 (06) : 732 - 737
  • [5] X-ray computed tomography for non-destructive analysis of early Medieval swords
    Stelzner, Joerg
    Gauss, Florian
    Schuetz, Philipp
    STUDIES IN CONSERVATION, 2016, 61 (02) : 86 - 101
  • [6] Employing X-ray computed tomography for the non-destructive ice cores analysis
    Khairedinova, A. G.
    Kutuzov, S. S.
    Mikhalenko, V. N.
    Korost, D., V
    Khomyak, A. N.
    LED I SNEG-ICE AND SNOW, 2020, 60 (02): : 182 - 191
  • [7] On the non-destructive measurement of local mass transfer using X-ray computed tomography
    Wang, D.
    Huang, Y.
    Ewing, D.
    Chow, T.
    Cotton, J.
    Noseworthy, M. D.
    Ching, C. Y.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 81 : 531 - 541
  • [8] At the grass roots: non-destructive root phenotyping using X-ray computed tomography
    Kirschner, Gwendolyn K.
    PLANT JOURNAL, 2025, 121 (03):
  • [9] X-RAY INDUCED ACOUSTIC COMPUTED TOMOGRAPHY FOR NON-DESTRUCTIVE TESTING OF AIRCRAFT STRUCTURE
    Tran, Tiffany
    Samant, Pratik
    Xiang, Liangzhong
    Liu, Yingtao
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 1, 2019,
  • [10] Non-destructive PCB Reverse Engineering Using X-ray Micro Computed Tomography
    Asadizanjani, Navid
    Shahbazmohamadi, Sina
    Tehranipoor, Mark
    Forte, Domenic
    ISTFA 2015: CONFERENCE PROCEEDINGS FROM THE 41ST INTERNATIONAL SYMPOSIUM FOR TESTING AND FAILURE ANALYSIS, 2015, : 164 - 172