A Simple Structure Passive MPPT Standalone Wind Turbine Generator System

被引:8
|
作者
Bai, Yinru [1 ]
Kou, Baoquan [1 ]
Chan, C. C. [1 ]
机构
[1] Harbin Inst Technol, Sch Elect Engn & Automat, Harbin 150001, Peoples R China
关键词
Maximum power point tracking (MPPT); passive; permanent magnet (PM) synchronous generator; wind power; DESIGN;
D O I
10.1109/TMAG.2015.2439043
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Conventional maximum power point tracking (MPPT) methods for standalone wind turbine generator systems (SWTGSs) rely on a dc/dc converter or some other electrical control device. However, the electronic components contained in the electrical control device are likely to break down when exposed to extreme weathers, thereby resulting in the low reliability of SWTGS for outdoor use. To overcome this drawback, this paper proposes a simple structure passive MPPT SWTGS that can track the MPPs automatically without the use of a dc/dc converter or any other electrical control device. Thus, the proposed system is highly reliable for outdoor use. Moreover, the novel permanent magnet synchronous generator contained in the proposed system has a very simple structure. Therefore, the proposed system is easy to manufacture, and thus presents a practical solution. This paper explains the passive MPPT process, and analyzes the operating principle of the proposed system. A prototype is manufactured, and its MPPT performance is confirmed by experimental results.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] A Simple Structure Passive MPPT Stand-alone Wind Turbine Generator System
    Bai, Y.
    Kou, B.
    Chan, C.
    2015 IEEE MAGNETICS CONFERENCE (INTERMAG), 2015,
  • [2] Condition monitoring of a wind turbine generator using a standalone wind turbine emulator
    Himani
    Ratna DAHIYA
    Frontiers in Energy, 2016, 10 (03) : 286 - 297
  • [3] Condition monitoring of a wind turbine generator using a standalone wind turbine emulator
    Himani
    Dahiya, Ratna
    FRONTIERS IN ENERGY, 2016, 10 (03) : 286 - 297
  • [4] Condition monitoring of a wind turbine generator using a standalone wind turbine emulator
    Ratna Himani
    Frontiers in Energy, 2016, 10 : 286 - 297
  • [5] Doubly Fed Induction Generator Based Standalone Wind Energy Conversion System with MPPT Capability
    Naidu, N. K. Swami
    Singh, Bhim
    2014 6TH IEEE POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2014,
  • [6] Modeling of Wind Turbine Generator with Boost Converter MPPT
    Stefan, Lazarus
    Yusivar, Feri
    2018 2ND INTERNATIONAL CONFERENCE ON SMART GRID AND SMART CITIES (ICSGSC 2018), 2018, : 100 - 104
  • [7] Limit cycle based simple MPPT control scheme for a small sized wind turbine generator system - Principle and experimental verification
    Matsui, M
    Xu, DH
    Kang, LY
    Yang, ZQ
    IPEMC 2004: THE 4TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2004, : 1746 - 1750
  • [8] PMSG Based Standalone Wind Electric Conversion System with MPPT
    Sahin, P.
    Resmi, R.
    Vanitha, V.
    IEEE INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGICAL TRENDS IN COMPUTING, COMMUNICATIONS AND ELECTRICAL ENGINEERING (ICETT), 2016,
  • [9] Standalone Operation Of Wind Turbine Operated Self Excited Induction Generator
    Rani, Asha
    Shankar, Gauri
    2016 3RD INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN INFORMATION TECHNOLOGY (RAIT), 2016, : 321 - 325
  • [10] Model simplification and optimization of a passive wind turbine generator
    Sareni, B.
    Abdelli, A.
    Roboam, X.
    Tran, D. H.
    RENEWABLE ENERGY, 2009, 34 (12) : 2640 - 2650