Determination of cadmium in environmental and biological reference materials using isotope dilution analysis with a double focusing ICP-MS: a comparison with quadrupole ICP-MS

被引:0
|
作者
Valles Mota, JP [1 ]
Encinar, JR [1 ]
de la Campa, MRF [1 ]
Alonso, JIG [1 ]
Sanz-Medel, A [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
D O I
10.1039/a901753d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A detailed examination of the performance of a double focusing (DF) sector field ICP-MS (Element, Finnigan MAT) for the ID-ICP-MS determination of cadmium in biological and environmental samples is described and compared with a quadrupole-based instrument (HP4500, Hewlett Packard). Experimental parameters governing the instrumental precision and accuracy for isotope ratio measurements of cadmium in the DF-ICP-MS are first characterized. Systematic errors, including dead time, mass bias effects and spectroscopic interferences, can be easily corrected in the two instruments studied. Detector dead time has only to be taken into account using the DF-ICP-MS. Typical isotope ratio precisions of 0.2-0.3% can be obtained routinely with both instruments. However, the precision of the measurements in the DF-ICP-MS can be improved (< 0.1%) by increasing the number of scans. Moreover, for very low cadmium concentrations the DF-ICP-MS at low resolution setting (R=300) can provide better isotope ratio precision than the quadrupole ICP-MS because of its higher sensitivity. Both ICP-MS instruments were successfully applied to the determination of very low levels of cadmium by ID-ICP-MS (by both conventional and on-line ID modes) in biological and environmental certified reference materials, including Freeze-Dried Urine NIST SRM-2670, Horse Kidney IAEA H-8, Lichens BCR TP-25, Marine Sediment PACS-1 and Riverine Water SLRS-3. Combined uncertainty associated with the determinations is addressed.
引用
收藏
页码:1467 / 1473
页数:7
相关论文
共 50 条
  • [1] Double-focusing ICP-MS for the analysis of biological materials
    Marchante-Gayón, JM
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (03) : 335 - 337
  • [2] Double-focusing ICP-MS for the analysis of biological materials
    Juan Manuel Marchante-Gayón
    Analytical and Bioanalytical Chemistry, 2004, 379 : 335 - 337
  • [3] Spectral interferences in the analysis of cadmium in human blood by ICP-MS: comparison between high resolution sector field ICP-MS and quadrupole ICP-MS
    Vrijens, Jan
    Couck, Pedro
    Schroijen, Carmen
    Baeyens, Willy
    Leermakers, Martine
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (09) : 1819 - 1826
  • [4] Determination of plutonium isotopes in seawater reference materials using isotope-dilution ICP-MS
    Zheng, Jian
    Yamada, Masatoshi
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 1944 - 1948
  • [5] Determination of selenium in biological materials by isotope dilution analysis with an octapole reaction system ICP-MS
    García Alonso, J.I. (jiga@sauron.quimica.uniovi.es), 1600, Royal Society of Chemistry (18):
  • [6] Determination of selenium in biological materials by isotope dilution analysis with an octapole reaction system ICP-MS
    Reyes, LH
    Gayón, JMM
    Alonso, JIG
    Sanz-Medel, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (01) : 11 - 16
  • [7] Analysis of cadmium and lead in sediment by isotope-dilution ICP-MS
    Inagaki, K
    Takatsu, A
    Nakama, A
    Uchiumi, A
    Okamoto, K
    BUNSEKI KAGAKU, 2001, 50 (12) : 829 - 835
  • [8] Analytical accuracy in ICP-MS using isotope dilution and its application to reference materials
    Catterick, T
    Handley, H
    Merson, S
    ATOMIC SPECTROSCOPY, 1995, 16 (06) : 229 - 234
  • [9] Determination of plutonium in environmental samples with quadrupole ICP-MS
    C. Greis
    S. Karlsson
    A. Düker
    H. Pettersson
    B. Allard
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 275 : 55 - 70
  • [10] Determination of plutonium in environmental samples with quadrupole ICP-MS
    Greis, C.
    Karlsson, S.
    Duker, A.
    Pettersson, H.
    Allard, B.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 275 (01) : 55 - 70