DETERMINATION OF RESERVOIR DRAINAGE AREA FOR CONSTANT-PRESSURE SYSTEMS USING WELL TEST DATA

被引:0
|
作者
Escobar, Freddy-Humberto [1 ]
Hernandez, Yuly-Andrea [2 ]
Tiab, Djebbar [3 ]
机构
[1] Univ Surcolombiana, Neiva, Huila, Colombia
[2] Columbus Energy Sucursal Colombia, Bogota, Colombia
[3] Univ Oklahoma, Norman, OK 73019 USA
来源
CT&F-CIENCIA TECNOLOGIA Y FUTURO | 2010年 / 4卷 / 01期
关键词
reservoir; pressure; well testing; reservoir drainage area; pseudosteady state; TDS Technique;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this work, the conventional cartesian straight-line pseudosteady-state solution and the Total Dissolved Solids (TDS) solution to estimate reservoir drainage area is applied to constant-pressure reservoirs to observe its accuracy. It was found that it performs very poorly in such systems, especially in those having rectangular shape. On the other hand, the pseudosteady-state solution of the TDS technique performs better in constant-pressure systems and may be applied only to regular square-or circular-shaped reservoirs with a resulting small deviation error. Therefore, new solutions for steady-state systems in circular, square and rectangular reservoir geometries having one or two constant-pressure boundaries are developed, compared and successfully verified with synthetic and real field cases. Automatic matching performed by commercial software sometimes are so time consuming and tedious which leads to another reason to use the proposed equations.