Assessing the measurement of airway resistance by the interrupter technique

被引:0
|
作者
Zuriarrain Reyna, Yolanda [1 ]
Lopez Neyra, Alejandro [1 ]
Sanz Santiago, Veronica [1 ]
Almeria Gil, Esmeralda [1 ]
Villa Asensi, Jose Ramon [1 ]
机构
[1] Hosp Infantil Univ Nino Jesus, Pulmonol Div, Madrid, Spain
来源
ARCHIVOS ARGENTINOS DE PEDIATRIA | 2013年 / 111卷 / 06期
关键词
airway resistance; Rint; pulmonary function; assessment study; pediatric age; RESPIRATORY RESISTANCE; PRESCHOOL-CHILDREN; REFERENCE VALUES; YOUNG-CHILDREN; ASTHMA; BRONCHODILATION; INSPIRATION; DEVICE;
D O I
10.5546/aap.2013.495
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Introduction. Pulmonary function tests allow an objective assessment of the degree of bronchial obstruction in collaborative subjects. The measurement of airway resistance using passive methods is very helpful in non-collaborative subjects. The objective of this study was to assess the applicability of measuring airway resistance by the interrupter technique (Rint) in pediatric subjects, determining its reproducibility, reliability and accuracy versus other techniques to measure airway resistance. Material and Methods. Cross-sectional study in healthy children and in children with an obstructive airway disease, all aged 2-18 years old. The Rint was measured using a portable device and results were compared to airway resistance measured by oscillometry and plethysmography. The reproducibility of measurements and the influence of the different outcome measures (use of mask or mouthpiece, cheek support, or nose clip) were assessed. Results. Valid measurements were obtained in 82.6% of 460 children (47.6% younger than 7 years old). Reproducibility was very good (ICC= 0.9412; p <0.00001), and no differences were found among the measurements obtained at separate time intervals (0.75 +/- 0.3 versus 0.74 +/- 0.28; p=0.435). None of the factors indicated before had an effect on the reproducibility of measurements. Resistance values obtained by plethysmography and oscillometry were higher than those obtained using the Rint, with a positive correlation between them. The higher the degree of airway obstruction, the worse the correlation with plethysmography. Conclusions. The Rint measurement is a plausible and reproducible technique, and has an adequate correlation with the resistance measurements obtained using oscillometry or plethysmography, thus making it useful for non-collaborative patients. In patients with airway obstruction, this technique could underestimate resistance, so it would be a hurdle to use it to follow-up subjects with a moderate to severe obstructive disease or in bronchial challenge tests.
引用
收藏
页码:495 / 501
页数:7
相关论文
共 50 条
  • [1] Airway resistance measurement using the interrupter technique
    Gaultier, C
    REVUE DES MALADIES RESPIRATOIRES, 1999, 16 : S163 - S164
  • [2] RENAISSANCE OF INTERRUPTER TECHNIQUE FOR MEASUREMENT OF AIRWAY-RESISTANCE
    BERGER, D
    NOLTE, D
    PRAXIS UND KLINIK DER PNEUMOLOGIE, 1979, 33 (05): : 726 - 730
  • [3] RE-EVALUATION OF INTERRUPTER TECHNIQUE FOR AIRWAY-RESISTANCE MEASUREMENT
    JACKSON, AC
    MILHORN, HT
    NORMAN, JR
    JOURNAL OF APPLIED PHYSIOLOGY, 1974, 36 (02) : 264 - 268
  • [4] Measurement of airway resistance using the interrupter technique in preschool children in the ambulatory setting
    Bridge, PD
    Ranganathan, S
    McKenzie, SA
    EUROPEAN RESPIRATORY JOURNAL, 1999, 13 (04) : 792 - 796
  • [5] Interrupter technique for assessing respiratory resistance: a review
    Kivastik, Jana
    Talts, Jaak
    Jagomaegi, Kersti
    Raamat, Rein
    PROCEEDINGS OF THE ESTONIAN ACADEMY OF SCIENCES, 2014, 63 (03) : 247 - 252
  • [6] Assessment of bronchodilator response by airway resistance measurement using the interrupter resistance (Rint) technique in preschool children
    Lis, Grzegorz
    Durlak, Wojciech
    Cichocka-Jarosz, Ewa
    Jedynak-Wasowicz, Ula
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [7] MEASUREMENT OF RESPIRATORY ELASTANCE AND RESISTANCE BY INTERRUPTER TECHNIQUE
    GOTTFRIED, SB
    ROSSI, A
    CALVERLEY, PMA
    ZOCCHI, L
    MILICEMILI, J
    FEDERATION PROCEEDINGS, 1983, 42 (04) : 1095 - 1095
  • [8] Airway resistance by the interrupter technique: Which algorithm for measuring pressure??
    Pao, CS
    Healy, MJR
    McKenzie, SA
    PEDIATRIC PULMONOLOGY, 2004, 37 (01) : 31 - 36
  • [9] Correlation between plethysmographic airway resistance and the interrupter technique in children
    Onorato, J
    Morandi, B
    Morelli, M
    Scovena, E
    Rizzi, M
    Greco, M
    Andreoli, A
    Sergi, M
    Principi, N
    RIVISTA ITALIANA DI PEDIATRIA-ITALIAN JOURNAL OF PEDIATRICS, 1996, 22 (03): : 350 - 356
  • [10] AN INTERRUPTER METHOD FOR MEASUREMENT OF AIRWAY-RESISTANCE IN SMALL ANIMALS
    SCHLESINGER, RB
    ZECCARDI, AV
    MONAHAN, J
    JOURNAL OF APPLIED PHYSIOLOGY, 1980, 48 (06) : 1092 - 1095