Modified Dual Piezo Configuration for Improved Structural Health Monitoring Using Electro-Mechanical Impedance (EMI) Technique

被引:10
|
作者
Adhikari, S. [1 ,2 ]
Bhalla, S. [2 ]
机构
[1] Tribhuvan Univ, IOE Pashchimanchal Campus, Pokhara, Nepal
[2] Indian Inst Technol Delhi, Dept Civil Engn, New Delhi 110016, India
关键词
Structural health monitoring (SHM); Lead zirconate titanate (PZT); Electro-mechanical impedance (EMI) technique; Dual piezo configuration (DPC); Modified dual piezo configuration (MDPC); Sensors; Actuators;
D O I
10.1007/s40799-018-0249-y
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents a new variant of the electro-mechanical impedance (EMI) technique encompassing sensor-actuator dual configuration for improved damage assessment. In this arrangement, called as dual piezo configuration (DPC), an outer piezoelectric ring acts as the actuator and an inner piezoelectric disc as the sensor. The configuration yields better results than the conventional EMI configuration employing the same piezo patch as the sensor as well as the actuator. This paper presents a more practical and modified version of DPC entailing a group of normal commercially available PZT patches. The piezo sensor configurations evaluated in the paper are: (a) single piezo configuration (SPC), which is conventionally employed in the EMI technique; (b) dual piezo configuration (DPC), which consists two different patches in ring type configuration; and (c) modified dual piezo configuration (MDPC), which uses four outer piezo patches for the actuation and a centrally located piezo patch for the sensing purpose. The paper first covers the comparison of the three configurations through finite element method (FEM), using an aluminum block of dimensions 48x48x10mm as the host structure and lead zirconate titanate (PZT) patches of size 10x10x0.3mm, analyzed through coupled field analysis. The simulation study is followed by an experiment on the aluminum block of the same size and finally on a prototype steel plate of dimensions 1200x970x8mm. Simulation results and experimental data prove that the proposed MDPC is much more sensitive to the occurrence than the conventional SPC. Also, MDPC ensures much larger zone of influence as compared to the conventional SPC as well as the DPC and it commands higher sensitivity. Hence, it can be employed on the large structures to detect damage, which is not possible by using the SPC which may warrant very large number of sensors. Thus, the proposed MDPC approach can be practically employed to detect the damage in large civil, mechanical and aerospace structures.
引用
收藏
页码:25 / 40
页数:16
相关论文
共 50 条
  • [1] Modified Dual Piezo Configuration for Improved Structural Health Monitoring Using Electro-Mechanical Impedance (EMI) Technique
    S. Adhikari
    S. Bhalla
    Experimental Techniques, 2019, 43 : 25 - 40
  • [2] A low-cost variant of electro-mechanical impedance (EMI) technique for structural health monitoring
    R. Panigrahi
    S. Bhalla
    A. Gupta
    Experimental Techniques, 2010, 34 : 25 - 29
  • [3] Investigation of Shear Force Mechanism in Electro-Mechanical Impedance (EMI) Technique for Structural Health Monitoring
    Moharana, S.
    Bhalla, S.
    STRUCTURAL HEALTH MONITORING 2013, VOLS 1 AND 2, 2013, : 2079 - 2088
  • [4] A LOW-COST VARIANT OF ELECTRO-MECHANICAL IMPEDANCE (EMI) TECHNIQUE FOR STRUCTURAL HEALTH MONITORING
    Panigrahi, R.
    Bhalla, S.
    Gupta, A.
    EXPERIMENTAL TECHNIQUES, 2010, 34 (02) : 25 - 29
  • [5] Structural health monitoring using electro-mechanical impedance sensors
    Park, S.
    Yun, C. -B.
    Inman, D. J.
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2008, 31 (08) : 714 - 724
  • [6] Electro-mechanical Impedance Technique for Structural Health Monitoring of Composite Panels
    Schwankl, Martin
    Khodaei, Z. Sharif
    Aliabadi, M. H.
    Weimer, C.
    ADVANCES IN FRACTURE AND DAMAGE MECHANICS XI, 2013, 525-526 : 569 - +
  • [7] Piezoelectric Electro-Mechanical Impedance (EMI) Based Structural Crack Monitoring
    Wang, Tao
    Tan, Bohai
    Lu, Mingge
    Zhang, Zheng
    Lu, Guangtao
    APPLIED SCIENCES-BASEL, 2020, 10 (13):
  • [8] Electro-mechanical impedance technique for health monitoring of concrete structures
    Bahei-El-Din, Y.A.
    Saleh, A.M.
    Talaat, M.M.
    Journal of Engineering and Applied Science, 2003, 50 (06): : 1111 - 1124
  • [9] Integration of Electro-mechanical Impedance and Global Dynamic Techniques for Improved Structural Health Monitoring
    Shanker, Rama
    Bhalla, Suresh
    Gupta, Ashok
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2010, 21 (03) : 285 - 295
  • [10] Load and Structural Health Monitoring of a Scaled CFRP Rudder Stock using Electro-Mechanical Impedance Technique
    Moll, Jochen
    Schmidt, Matthias
    Kaesgen, Johannes
    Mehldad, Joerg
    Buecker, Marcel
    Haupt, Felix
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS IX, 2020, 11381