Modification of the TASMIP x-ray spectral model for the simulation of microfocus x-ray sources

被引:8
|
作者
Sisniega, A. [1 ,2 ]
Desco, M. [1 ,2 ,3 ]
Vaquero, J. J. [1 ,2 ]
机构
[1] Univ Carlos III Madrid, Dept Bioingn & Ingn Aeroespacial, ES-28911 Madrid, Spain
[2] Inst Invest Sanitaria Gregorio Maranon, ES-28007 Madrid, Spain
[3] Ctr Invest Biomed Red Salud Mental CIBERSAM, ES-28029 Madrid, Spain
关键词
x-ray spectra; computer simulation; radiation dose; micro-CT; breast imaging; microfocus source; MONTE-CARLO-SIMULATION; DIAGNOSTIC-RADIOLOGY; OPTIMIZATION; TARGET; MOLYBDENUM; SYSTEM;
D O I
10.1118/1.4837220
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The availability of accurate and simple models for the estimation of x-ray spectra is of great importance for system simulation, optimization, or inclusion of photon energy information into data processing. There is a variety of publicly available tools for estimation of x-ray spectra in radiology and mammography. However, most of these models cannot be used directly for modeling microfocus x-ray sources due to differences in inherent filtration, energy range and/or anode material. For this reason the authors propose in this work a new model for the simulation of microfocus spectra based on existing models for mammography and radiology, modified to compensate for the effects of inherent filtration and energy range. Methods: The authors used the radiology and mammography versions of an existing empirical model [tungsten anode spectral model interpolating polynomials (TASMIP)] as the basis of the microfocus model. First, the authors estimated the inherent filtration included in the radiology model by comparing the shape of the spectra with spectra from the mammography model. Afterwards, the authors built a unified spectra dataset by combining both models and, finally, they estimated the parameters of the new version of TASMIP for microfocus sources by calibrating against experimental exposure data from a microfocus x-ray source. The model was validated by comparing estimated and experimental exposure and attenuation data for different attenuating materials and x-ray beam peak energy values, using two different x-ray tubes. Results: Inherent filtration for the radiology spectra from TASMIP was found to be equivalent to 1.68 mm Al, as compared to spectra obtained from the mammography model. To match the experimentally measured exposure data the combined dataset required to apply a negative filtration of about 0.21 mm Al and an anode roughness of 0.003 mm W. The validation of the model against real acquired data showed errors in exposure and attenuation in line with those reported for other models for radiology or mammography. Conclusions: A new version of the TASMIP model for the estimation of x-ray spectra in microfocus x-ray sources has been developed and validated experimentally. Similarly to other versions of TASMIP, the estimation of spectra is very simple, involving only the evaluation of polynomial expressions. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] X-ray crystallography with microfocus X-ray sources
    Arndt, UW
    Bloomer, AC
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS, 2000, 4144 : 86 - 94
  • [2] X-ray spectral signatures of the photon bubble model for ultraluminous X-ray sources
    Finke, Justin D.
    Bottcher, Markus
    ASTROPHYSICAL JOURNAL, 2007, 667 (01): : 395 - 403
  • [3] MODIFICATION OF A COSSLETT-NIXON MICROFOCUS X-RAY TUBE FOR USE AS AN X-RAY MICROANALYZER
    DILS, RR
    ZEITZ, L
    HUGGINS, RA
    KEITH, DL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1961, 32 (09): : 1040 - &
  • [4] Improved mirrors for use with microfocus X-ray sources
    Arndt, UW
    Bloomer, AC
    Pina, L
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS II, 2001, 4502 : 126 - 133
  • [5] A microfocus X-ray tube based on a microstructured X-ray target
    Ihsan, Aamir
    Heo, Sung Hwan
    Cho, Sung Oh
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (21-22): : 3566 - 3573
  • [6] Transmission W-Diamond X-Ray Target for High Brightness Microfocus X-Ray Sources
    Tan, Y.
    Kandlakunta, P.
    Liu, R.
    Zhou, S.
    Zhao, T.
    Zhang, T.
    MEDICAL PHYSICS, 2019, 46 (06) : E301 - E301
  • [7] SPECTRAL VARIABILITY IN X-RAY SOURCES
    THOMAS, RM
    DULDIG, ML
    GREENHILL, JG
    NATURE, 1977, 267 (5609) : 332 - 333
  • [8] X-ray imaging with compound refractive lens and microfocus X-ray tube
    Pina, Ladislav
    Dudchik, Yury
    Jelinek, Vaclav
    Sveda, Libor
    Marsik, Jiri
    Horvath, Martin
    Petr, Ondrej
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS III, 2008, 7077
  • [9] Microfocus X-Ray Tubes with a Silicon Autoemission Nanocathode as an X-Ray Source
    Dyuzhev, N. A.
    Demin, G. D.
    Gryazneva, T. A.
    Pestov, A. E.
    Salashchenko, N. N.
    Chkhalo, N. I.
    Pudonin, F. A.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2018, 45 (01) : 1 - 5
  • [10] Microfocus X-Ray Tubes with a Silicon Autoemission Nanocathode as an X-Ray Source
    N. A. Dyuzhev
    G. D. Demin
    T. A. Gryazneva
    A. E. Pestov
    N. N. Salashchenko
    N. I. Chkhalo
    F. A. Pudonin
    Bulletin of the Lebedev Physics Institute, 2018, 45 : 1 - 5