Leak Detection in Viscoelastic Pipe by Transient Analysis

被引:0
|
作者
Taieb, Lamjed Hadj [1 ]
Ayed, Lazhar [1 ]
Taieb, Ezzeddine Hadj [1 ]
机构
[1] Ecole Natl Ingn Sfax, UR Mecan Fluides Appl & Modelisat, Bpw 3038, Sfax, Tunisia
关键词
leak detection; viscoelastic pipe; water hammer;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The use of fluid transients has the potential to provide insight into effect of leaks in pipeline systems and hence provide leak detection method. This paper presents a technique for detection and location of leaks in a single viscoelastic pipe by means of transient analysis. The method uses transient pressure waves initiated by the sudden closure of an upstream valve. The presence of a leak in a pipe partially reflects these pressure waves and allows for the location and magnitude of leaks. The two constitutive equations of continuity and momentum yield a set of two partial differential equations of hyperbolic type. The viscoelastic behaviour of the pipe wall material is represented by a generalized Kelvin-Voigt model. The computed results obtained by the method of characteristics describe the influence of the leak on head and discharge time-histories. The effect of the pipe wall viscoelasticity on the leak detection and sizing is also discussed.
引用
收藏
页码:69 / 79
页数:11
相关论文
共 50 条
  • [1] Transient wave-leak interaction analysis for improved leak detection in viscoelastic pipelines
    Zhang, Ying
    Duan, Huan-Feng
    Keramat, Alireza
    Pan, Bin
    Meniconi, Silvia
    Brunone, Bruno
    Lee, Pedro J.
    MEASUREMENT, 2023, 208
  • [2] Transient generation in pipe networks for leak detection
    Haghighi, Ali
    Shamloo, Hamid
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-WATER MANAGEMENT, 2011, 164 (06) : 311 - 318
  • [3] Leak detection by inverse transient analysis in an experimental PVC pipe system
    Soares, Alexandre Kepler
    Covas, Didia I. C.
    Reis, Luisa Fernanda R.
    JOURNAL OF HYDROINFORMATICS, 2011, 13 (02) : 153 - 166
  • [4] Optimum leak detection and calibration of pipe networks by inverse transient analysis
    Shamloo, Hamid
    Haghighi, Ali
    JOURNAL OF HYDRAULIC RESEARCH, 2010, 48 (03) : 371 - 376
  • [5] Case Studies of Leak Detection and Location in Water Pipe Systems by Inverse Transient Analysis
    Covas, Didia
    Ramos, Helena
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2010, 136 (02) : 248 - 257
  • [6] Leak Detection in Pipe Using Controllable and Low-pressure Transient Analysis Method
    Li, Jiazhen
    Yu, Hongjing
    Guo, Xinlei
    Guo, Yongxin
    Wang, Tao
    Fu, Hui
    Huang, Wei
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2022, 30 (04): : 873 - 882
  • [7] Leak detection in pipe using transient flow and genetic algorithm
    Young-joon Kim
    Koji Miyazaki
    Hiroshi Tsukamoto
    Journal of Mechanical Science and Technology, 2008, 22 : 1930 - 1936
  • [8] Leak detection in pipe using transient flow and genetic algorithm
    Kim, Young-Joon
    Miyazaki, Koji
    Tsukamoto, Hiroshi
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2008, 22 (10) : 1930 - 1936
  • [9] Sensitivity analysis in pipe network leak detection
    Curto, G
    Napoli, E
    3RD INTERNATIONAL CONFERENCE ON WATER PIPELINE SYSTEMS: LEAKAGE MANAGEMENT, NETWORK OPTIMIZATION, AND PIPELINE REHABILITATION TECHNOLOGY, 1997, (23): : 245 - 257
  • [10] Leak detection in water-delivering pipe system based on transient frequency response analysis
    Liu, Zhiyong
    Liu, Meiqing
    Jiang, Jin
    Liang, Xing
    Shuili Xuebao/Journal of Hydraulic Engineering, 2015, 46 (11): : 1352 - 1359