Vastus medialis H-reflex reliability during standing

被引:8
|
作者
Alrowayeh, HN [1 ]
Sabbahi, MA [1 ]
机构
[1] Texas Womans Univ, Sch Phys Therapy, Houston, TX 77030 USA
关键词
vastus medialis; H-reflex; standing;
D O I
10.1097/01.wnp.0000193632.75002.d3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Vastus medialis H-reflex is a valid measure to examine quadriceps muscle voluntary activation and inhibition after knee injury. Its reliability during repeated sessions has not been established. The purpose of this study was to establish the intrasession and intersession reliability of vastus medialis H-reflex amplitude recordings during standing with varied knee flexion angles (0, 30, 45, and 60 degrees). Electromyography unit was used to elicit and record the vastus medialis H-reflex from the right leg of five healthy subjects. The femoral nerve was stimulated using 0.5-millisecond pulses at 0.2 pps of H-maximum. Four recordings of the vastus medialis H-reflex amplitude were recorded in three trials for each knee flexion angle within each session for two consecutive days. Reliability was calculated using intraclass correlation coefficients (ICC). Intrasession reliability during standing with varied knee angles was high (ICC [2, 4] range from 0.76 to 0.98), and intersession reliability during standing with varied knee angles was moderate to high (ICC [2, 1] range from 0.51 to 0.84). Recording four traces of vastus medialis H-reflex amplitude per trial was reliable. Vastus medialis H-reflex amplitude recordings while standing during varied knee flexion are reliable within and between sessions.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [1] Reliability of H-reflex in vastus lateralis and vastus medialis muscles during passive and active isometric conditions
    Valentin Doguet
    Marc Jubeau
    European Journal of Applied Physiology, 2014, 114 : 2509 - 2519
  • [2] Reliability of H-reflex in vastus lateralis and vastus medialis muscles during passive and active isometric conditions
    Doguet, Valentin
    Jubeau, Marc
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2014, 114 (12) : 2509 - 2519
  • [3] Reliability of the soleus H-reflex from supine to standing in young and elderly
    Mynark, RG
    CLINICAL NEUROPHYSIOLOGY, 2005, 116 (06) : 1400 - 1404
  • [4] Intersession reliability of a protocol to assess reflex activation history in the vastus medialis
    Palmieri, RM
    Ingersoll, CD
    INTERNATIONAL JOURNAL OF NEUROSCIENCE, 2005, 115 (05) : 735 - 740
  • [5] Reliability of the FCR H-reflex
    Christie, AD
    Inglis, JG
    Boucher, JP
    Gabriel, DA
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2005, 22 (03) : 204 - 209
  • [6] The effects of body weight on the soleus H-reflex modulation during standing
    Hwang, Sujin
    Jeon, Hye-Seon
    Kwon, Oh-Yun
    Yi, Chung-Hwi
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2011, 21 (03) : 445 - 449
  • [7] Effect of Ankle Angles on the Soleus H-Reflex Excitability During Standing
    Dutt-Mazumder, Aviroop
    Segal, Richard L.
    Thompson, Aiko K.
    MOTOR CONTROL, 2020, 24 (02) : 189 - 203
  • [8] Effects of active and sham tDCS on the soleus H-reflex during standing
    McCane, Lynn M.
    Wolpaw, Jonathan R.
    Thompson, Aiko K.
    EXPERIMENTAL BRAIN RESEARCH, 2023, 241 (06) : 1611 - 1622
  • [9] COMPARISON OF AMPLITUDE OF HUMAN SOLEUS H-REFLEX DURING SITTING AND STANDING
    HAYASHI, R
    TAKO, K
    TOKUDA, T
    YANAGISAWA, N
    NEUROSCIENCE RESEARCH, 1992, 13 (03) : 227 - 233
  • [10] Spinal Reflex Arc Excitability Corresponding to the Vastus Medialis Obliquus and Vastus Medialis Longus Muscles
    Tanino, Yoshitsugu
    Suzuki, Toshiaki
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2014, 26 (01) : 101 - 104